• Title/Summary/Keyword: Insulation Material

Search Result 1,342, Processing Time 0.032 seconds

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

Analysis of Propagation Characteristics of Acoustic Signal in Insulation Oil (음향신호의 유중 전파특성 분석)

  • Yun, Min-Young;Park, Kyoung-Soo;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.114-119
    • /
    • 2016
  • This paper dealt with the propagation characteristics of acoustic signal in insulation oil for the purpose of improving the reliability of AE (acoustic emission) method used for condition monitoring of oil-immersed transformers. A discharge source was placed in insulation oil and AE sensors ($f_c$ :140 kHz) were attached on the oil tank to study the changes of velocity and propagation path with the depth and distance. The average velocity was 1,436 m/s and the velocity decreased with the increase of depth from the oil surface to 430 mm. The propagation paths were classified into three sections by the shortest reflection path of the detected signal. The minimum distinguishable distance in each section was 70 mm. It was also verified that PD (partial discharge) with a magnitude over than 500 pC can be detected by the AE sensors.

Thermal Properties of DGEBHA/MDA/SN/zeolite System Degraded by Moisture Absorption

  • Kim, You-Jeong;Lee, Hong-Ki;Kim, Sang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.479-482
    • /
    • 1999
  • Cured epoxy resins are extensively used for the electrical insulation in high-voltage equipments. The bisphenol A-based epoxy resins lured with azine show, especially, good thermal properties and mechanical resistances. For the technical and economic reasons, varing amount of inorganic fillers are added to endow the required special properties. In the large generators and motors of power plants, epoxy insulation is disclosed to the harsh conditions like the superheated steam and abrupt temperature variation. Hygrothermal aging at elevated temperatures tends to induce degradation in epoxy resins. To predict the effect of this degradation in DGEBA/MDA/SN/zeolite system, we proceeded the forced moisture absorption experiment using the autoclave. The thermal properties of the untreated and treated specimens were analyzed by DSC and TGA under the nitrogen flowing condition. The moisture absorption results showed a weight increase during hygrothermal aging at 1207. At the initial aging period, the system leaded to more or less postcuring but more prolonged environmental aging leaded the discoloration of specimen and lowering the T$_{g}$./.

  • PDF

A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices (저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구)

  • Kil Gyung-Suk;Song Jae-Yong;Moon Seung-Bo;Cha Myung-Soo;Hwang Don-Ha;Kang Dong-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

A Study on Insulating Design and Test of Mini-Model windings for a 22.9 kV Class HTS Transformer Reducing AC Loss (저손실 22.9 kV급 고온초전도 변압기를 위한 미니 모델 권선의 절연 설계 및 시험 연구)

  • Baek, Seung-Myeong;Cheon, Hyeon-Gweon;Nguyen, Van Dung;Kwag, Dong-Sun;Lee, Chang-Hwa;Kim, Hea-Jong;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.94-99
    • /
    • 2004
  • This paper presents experimental data from model windings with different arrangement of coil in order to provide information to design a 22.9 kV class HTS transformer. Before experiment, the composite insulation of two different type of HTS transformers are investigated. The first basic of investigation is a breakdown characteristic of liquid nitrogen and flashover characteristic on the GFRP surface under ac and impulse, The second investigation is insulation design, manufacture and test of model windings. These include a AC withstand voltage test of 50 kV rms and a lighting impulse test of 150 kV at peak.

  • PDF

Electrical Breakdown Characteristics of Composite Insulation Composed of Epoxy Resins with N2, Dry-air in Non-uniform Field (불평등 전계 시 에폭시와 N2, dry-air 혼합절연체의 절연파괴특성)

  • Jung, Hae-Eun;Park, Seong-Hee;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.462-463
    • /
    • 2007
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of composite insulation composed of epoxy resins with N2, air are studied in non-uniform field. The gap of needle to plane was 3mm, 5mm. The pressure of air, nitrogen was varied within the range of 0.1~0.6MPa. The thickness of a needle is 1mm and the curvature radius of the end of needle is 100um. The diameter of a plane made of the stainless steel is 50mm. As a result of the experiment, the breakdown voltage is increased about 3 times when epoxy resins is composited. The thickness of epoxy resins filled opposite to electrode concentrated electric field weakly influences on breakdown voltage.

  • PDF

Bending strength of GFRP for Insulator according to Winding Angle (전기절연물용 GFRP의 winding 각도에 따른 굽힘강도)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Lee, Tae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.429-432
    • /
    • 2004
  • The demand for electric power keeps growing, and tends to be more effective. Polymer insulators have been manufactured for almost twenty years and the excellent insulation performance of polymer insulators is attractive. Polymeric materials are now widely used as a replacement for inorganic materials such as porcelain or glass for the outdoor insulation of high voltage insulation. GFRP has been used widely as a core materials for polymer insulators. This paper reports the mechanical properties of GFRP for insulators. The bending strength was simulated and evaluated according to the winding angle. The fiber orientation in GFRP has a great effect on the strength of GFRP because the strength of GFRP mainly depends on the strength of fiber. Results of simulated and evaluated strength of GFRP were compared each other. The simulated strength of GFRP rod was different from the evaluated strength. It was caused that the shear stress had a great effect on the strength of GFRP although the stress of parallel direction of GFRP was much higher.

  • PDF

Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable. (전력케이블 절연재료의 내부결함에 따른 전기적 특성)

  • Choi, Sang-Gi;Kim, Tag-Yong;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF

Analysis of Deterioration Characteristics of Polyvinyl Chloride Insulation Wires for Electrical Apparatus by Series Arcing (전기기기용 비닐절연전선에서의 직렬 아크에 의한 열화 특성 분석)

  • Kim, Hyang-Kon;Gil, Hyung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.234-235
    • /
    • 2006
  • In this study, we experimented deterioration characteristics of PVC insulation wires for electrical apparatus by series arcing and analyzed the heat generation at the contacts of wires, glowing/growing process of copper oxide, waveforms of contact voltage, current, power dissipation, and so on. We found out that how glowing contacts and surface arcing can decompose PVC insulation and that subsequent series arc can lead to ignition. We expect that these results are useful for improving fire protection technology by providing a better understanding of how electrical fires can initiate.

  • PDF

Effect of Ceramic Powder Content and Shape on the Electrical Properties of Ceramic(BaTiO3)-polymer(Epoxy) Composite for Embedded Capacitors (임베디드 커패시터용 세라믹(BaTiO3)-고분자(에폭시) 필름의 세라믹 분말 형상 및 함량에 따른 전기적 특성)

  • Han, Jeong-Woo;Yoon, Jung-Rag;Je, Hae-June;Lee, Dong-Ho;Lee, Kyung-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.495-500
    • /
    • 2009
  • The ceramic($BaTiO_3$)-polymer(epoxy) composites have been widely investigated as dielectric materials for embedded capacitors in printed circuit boards (PCBs). The dielectric properties of $BaTiO_3$/epoxy composites prepared using the agglomerated $BaTiO_3$ particles were investigated in the present study. The dielectric constants of the composites prepared using the agglomerated $BaTiO_3$ particles were about 2 times higher than those of the composites with the dispersed $BaTiO_3$ particles. The insulation resistance of the composites prepared using the agglomerated $BaTiO_3$ particles were lower than those of the composites with dispersed $BaTiO_3$ particles. As a result, there is tradeoff between high dielectric constant and insulation resistance in the $BaTiO_3$/epoxy composites. So it is important to select proper agglomerated or dispersed $BaTiO_3$ particles in accordance with needs.