• 제목/요약/키워드: Insulation Form

Search Result 188, Processing Time 0.03 seconds

Evaluating Insulation Performance of Form-tie in Sandwich Insulation Wall (폼타이 종류에 따른 중단열 벽체의 단열성능 평가)

  • Park, Jun-Ho;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.188-189
    • /
    • 2014
  • Nowadays, many research execute about sandwich-insulation wall for durability of wall and retaining insulation performance. But sandwich-insulation, different exterior and interior insulation, need to form-tie which supporting both side form. And because of it penetrate concrete wall, it is worried about thermal-bridge phenomenon to form-tie. So, this research classify penetration type and buried type and analysis thermal-phenomenon of each type's form-tie and insulation performance. As a result, all form-tie type little occur thermal-bridge but penetration form-tie have superior insulation performance and low U-value.

  • PDF

Compressive Strength Properties of Concrete by the Form Material Change at 10 below Zero (양생온도 -10℃에서 거푸집 재료 변화에 따른 콘크리트의 압축강도 특성)

  • Choi, Si-Hyun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.107-108
    • /
    • 2016
  • When the construction in a low temperature, the concrete performance is deteriorated by frost damage at early age. In this study, the form utilizing heating sheet and insulation is measured the performance to prevent frost damage at 10 below zero. It produced five types of the form and to measure the temperature history and compressive strength. At first, form attached heating sheet showed the highest temperature. But the form attached vacuum insulation showed the highest temperature ever since 12hours. In the case of compressive strength, the form attached heating sheet + isopink(polystyrene foam board) showed the highest compressive strength. It was followed by vacuum insulation. As a result, the form utilizing insulation and heating sheet helped to prevent frost damage.

  • PDF

A Experimental Study of Insulation Performance of Insulated Forms Utilizing NT frame Insulation at Low Temperature (저온환경하 NT(Nano Technology)구조 단열재를 사용한 단열거푸집의 열적성능평가에 관한 실험적 연구)

  • Park, Jang-Hyun;Kim, Mok-Kyu;Kim, Hyeong-Cheol;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.179-180
    • /
    • 2015
  • In this study, the experimental study on Insulation performance of insulated forms utilizing NT frame heat insulation at low Temperature. For this study, placing insulated TEGO film plywood based form between two constant temperature and humidity chamber that maintaining 10℃, decrease temperature of one chamber to -10℃ and -20℃. Each of steps, maintaining period of temperature was 1 hour. After placing the insulated form, measure temperature of outside if insulated form. As a result of experiment, temperature difference of Fumed Silica Vacuum insulation was lowest.

  • PDF

A Study on the Insulation Properties for Stator Form-wound Winding by Thermal Degradation Test (가속 열열화 시험에 의한 고정자 형권 코일의 절연특성에 관한 연구)

  • 채승훈;김상걸;오현석;신철기;왕종배;김기준;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.115-118
    • /
    • 2000
  • In case of developing new motor, many examinations was tested to decide a motor efficiency and reliability. To give reliability judgment, traction motor winding insulation was tested by electrical method after appling electrical, heat, mechanical, environmental stress. In this study, stator form-wound winding of traction motor in urban transit E.M.U was tested by accelerative thermal degradation test. Stator form-wound winding was tested on the accelerative degradation composed of heat, vibration, moisture, overvoltage and researched insulation resistance, dielectric loss, partial discharge for insulation degradation properties, evaluated withstand voltage. Degradation temperature was $230[^\circ{C}]$, $250[^\circ{C}]$, $270[^\circ{C}]$, for stator form-wound winding respectively. On the test results of accelerative thermal degradation, insulation properties were relied all temperature until 10 times and expected life was evaluated by the rule of reducing $10[^\circ{C}]$ life into halves. Expected life was 31.8 years. It is guaranteed insulation reliability because of exceeding 25 years life times as considering.

  • PDF

Assessment of Risk Factors for Application of Exterior Insulation Board in Cast-in-place Concrete Form System for Apartment (공동주택용 외단열 동시타설 공법 적용을 위한 리스크 요인 평가)

  • Cui, Jun-Long;Kim, Taehoon;Lim, Hyunsu;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.204-205
    • /
    • 2015
  • Exterior insulation board in cast-in-place concrete form system could reduce construction period and improve quality in apartment construction. However, the method is progressed with insulation and concrete frame works at the same time, then risk is increased in duration control and quality management. Therefore, this paper analyzed risk factors through FMEA method. We found that the key risk factors delaying schedule was insulation material that soaked in the rain and quality defects on the insulation material joint. Based on this research, the risk management approach should be developed for improvement of method activation.

  • PDF

Experimental Study on Properties of Temperature History Using Heating Sheet and Insulation Form at Low Temperature (발열시트 및 단열재를 사용한 거푸집 내부 콘크리트의 저온환경하 온도이력 특성에 관한 실험적 연구)

  • Choi, Si-Hyun;Lee, Han-Seung;Choi, Hyun-Kuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.132-139
    • /
    • 2017
  • In this study, in order to prevent the frost damage of the concrete, the characteristics of the form using heating sheet utilizing the chemical reaction of quicklime and the insulation were evaluated through experiments at low temperature. In the case of form at $-10^{\circ}C$, the form with attached heating sheet showed a temperature history of more than $10^{\circ}C$ higher than that of wood form at the early of concreting due to heat of the quicklime in the heating sheet. In the case of the insulated form, the concrete was kept at a high temperature by preserving the hydration heat. When the heating sheet and the isopink(extruded polystyrene) were attached together on the form, the effect was the same as that of the vacuum insulation. The compressive strength of the form with vacuum insulation and form with isopink, heating sheet as measured about 5 MPa at age 3. The experimental in Mongolia, as with the pervious results, the form with the heating sheet and the insulation showed the highest temperature history over $25^{\circ}C$ for 48 hours. Therefore, it was confirmed that the heating sheet and insulation are attached to the form, which helps the concrete strength development at low temperature by heat generation and the insulation effect.

A study on supplementary measure for the vulnerable part of insulated gang form in winter (동절기 단열갱폼 취약부 보완 대책에 관한 연구)

  • Choi, Suk;Lim, Myung-Kwan;Yoo, Jung-Il;Nam, Kyung-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.138-139
    • /
    • 2022
  • Through previous studies, it was reviewed how to improve the insulation performance of weak areas by installing heated wires as a solution to the corners pointed out as weak areas when applying the insulation gang form and the existing pouring areas.

  • PDF

Development of Forms for Cold Weather Concrete by Combination of Insulation (단열재 조합에 의한 한중콘크리트용 거푸집 개발)

  • Han, Cheon-Goo;Oh, Seon-Kyo;Sin, Dong-An;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.392-399
    • /
    • 2003
  • This paper discusses the validities of insulating curing of cold weather concreting at early stage by applying insulation forms. Tests were carried out using modified insulating form combining existing insulating form and various other insulations in order to develop improved insulation form. Temperature history of concrete using various insulating forms and insulation was measured to determine most effective combination of insulting form. According to results, as for the wall form, under the curing temperature of $-10^{\circ}C$, the temperature of concrete using Euro form drops sharply before 24 hours and lasts below $0^{\circ}C$ for 7 hours. The temperature of concrete using the form combining Polypropylene panel, styrofoam and plywood panel keep above $0^{\circ}C$. And, it is confirmed that the form mentioned above has a favorable effects on enhancing strength development of concrete and the cost to make the forms shows more reasonable than that of existing forms. However, as for the combination methods of insulation form for slab, which is composed of insulating form at the bottom of slab and various surface curing materials at the top of slab, in case of exposed condition at the top of slab, temperature history of concrete goes below $0^{\circ}C$ after 10 hours. In case of the combination of vinyl sheet and curing blanket, it drops below $0^{\circ}C$ after 42 hours. However, in case of the combination of vinyl, styrofoam and curing blanket, it does not go below $0^{\circ}C$ until 55 hours. Accordingly, compared to the case of exposure and the combination of vinyl and curing blanket, it indicates that the combination mentioned above has more effective insulating performance.

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.

A Study on the Complex Accelerating Degradation and Condition Diagnosis of Traction Motor for Electric Railway (전기철도용 견인전동기의 복합가속열화 상태진단에 관한 연구)

  • 왕종배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.93-101
    • /
    • 2002
  • In this study, the stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the C-Class(200$\^{C}$ ) insulation system of traction motors. The complex accelerative degradation was periodically performed during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, the condition diagnosis test such as insulation resistance '||'&'||' polarization index, capacitance '||'&'||' dielectric loss and partial discharge properties were investigated in the temperature range of 20 ∼ 160$\^{C}$. Relationship among condition diagnosis tests was analyzed to find a dominative degradation factor and an insulation state at end-life point.