• 제목/요약/키워드: Insulation Diagnosis test

검색결과 70건 처리시간 0.034초

소수력발전기 절연특성분석 (Analysis of Insulation Characteristic for Small Hydro Generator)

  • 오봉근;장정호;이광호;강동식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2008
  • Electrical insulation of small hydro generator stator winding is one of the most important parts in generator facilities. Some stator winding insulation problems can be identified through analysis of insulation diagnostic test. So, Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of small hydro generator. This paper presents case studies of insulation failure in generator stator windings and the results of insulation diagnostic test for small hydro generator stator windings. Especially, Conducting the insulation diagnostic test before the generator installed in site is very important process to keep the good insulation condition in service.

  • PDF

저주파수 전원을 이용한 전력케이블 절연평가에 관한 연구 (Power Cable Insulation Diagnosis Using Low Frequency Power)

  • 김성민;이상훈;장재열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1603-1603
    • /
    • 2011
  • As time goes by these cables make a insulation problems, and ask for a preventive diagnosis method. Cable has very high electrostatic capacity and insulation defects mainly caused by water-tree(WT). Dissipation factor test is very useful for detecting WT but it needs huge power supply. In this paper we presented a cable insulation diagnosis by dissipation factor using low frequency power supply.

  • PDF

고압전동기 고정자권선의 건조상태에 따른 절연특성 변화사례 고찰 (Example study of the insulation characteristic change according to the dryness condition in high voltage motor stator winding)

  • 공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2056-2057
    • /
    • 2008
  • This paper is purpose to understand the insulation properties of the high voltage motor stator winding according to the different dryness conditions. we carried out the three times insulation diagnosis test for the same motor stator winding. the first test object is the contaminated winding, second is the washed-out, and natural dried during the 24 hours, and the last is the heating dried in 110$^{\circ}C$ during the 48 hours. the insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, we analyzed and made a comparison of the three cases test result.

  • PDF

고압회전기 절연진단 및 수명평가 기술현황 (A technology State of Life Estimation and Insulation Diagnosis for High Voltage Rotating Machine)

  • 최영찬;왕종배;김기준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.31-35
    • /
    • 2000
  • We worried about the technology difference between our company and the advanced company at present motor market and are asked to set up the independent coil insulation system to accumulate insulation technology data. And to export our products at oversee market, we are asked to the evaluation of insulation performance to show our product excellence. In this study, we evaluated the insulation system of our motor, and studied the insulation diagnosis technology systematically to do site diagnosis. We are now accumulating the measured data. And also to reduce the initial insulation failure, we performed the insulation characteristic test and acquired the data to evaluate the initial soundness. We are doing the improvement of the insulation system. And also these data were used to new product development as very useful data, also will be used in the insulation deterioration diagnosis to estimate the remained life time which is very important data for the maintenance management. As the result, we were able to get our product reliability.

  • PDF

고압전동기 절연진단 결과 추이관리의 문제점 분석 (Analytic Issues for Trend Management on Insulation Diagnositic for High Voltage Motors)

  • 이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2052-2053
    • /
    • 2008
  • High voltage motors are the core equipment of electric generation facilities and need to guarantee stable operation. Therefore, keeping healthy state is of importance by means of insulation diagnosis periodically. However, if the diagnosis went through in the different circumstances such as temperature, humidity, and impedance applied to the test equipment, the trend analysis have no significance. This paper presents the experimental results supporting the importance of keeping the same conditions under insulation diagnosis.

  • PDF

회전기 고정자 권선에서의 운전 중 절연열화 진단기법 (On-Line Insulation Diagnosis Techniques for Stator Winding of Rotating Machines)

  • 윤대희;황돈하;신병철;김용주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.89-93
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines. And a novel on-line monitoring system for an insulation diagnosis is proposed.

  • PDF

발전기 고정자 권선의 정전용량 측정을 통한 흡습 진단 방법에 관한 연구 (A Study on the Water Absorption Diagnosis Method through Capacitance Measurement for Generator Stator Windings)

  • 김희수;배용채;기창두
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.50-57
    • /
    • 2006
  • The water leak in water-cooled generator stator windings can generate the serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them for the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. The developed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

대용량 몰드변압기 정밀절연진단 결과 고찰 (A study of Insulation Diagnosis for Large-Capacity Mold Transformer)

  • 이은춘;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.75-81
    • /
    • 2014
  • When the large-capacity Mold type Transformer was passed through rain, after it was dried and it's parts were changed, Insulation Diagnosis was made to evaluate the condition of it and decide to recharge. Using the evaluation of Insulation Diagnosis, the urgent decision-making for recharge made blackout time minimum. In this study, it was considered that Insulation Diagnosis for the large-capacity Mold type Transformer is applied to decision-making for reuse of high voltage electric power equipment by analysis of the case study.

견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가 (Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis)

  • 왕종배;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF