• 제목/요약/키워드: Insulation Degradation

검색결과 230건 처리시간 0.025초

열화된 XLPE 케이블의 열지급전류 (Thermally Stimulated Currents in Aged XLPE Cable Insulation)

  • 김상준;이남우;정동원;고인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.221-223
    • /
    • 1991
  • In order to evaluate degradation of the aged power cables, thin slices(200m) cut from the aged cables were prepared for thermally stimulated current measurements. Throughout the temperature range, 140 to $280^{\circ}C$ the TSC is greater for the aged material, and sharp peak is observed at $158^{\circ}C$ and $210^{\circ}C$.

  • PDF

전자파를 이용한 전동기 절연열화 진단시스템의 설계(2) (Design of Diagnosis System for Insulation Degradation of Motor by using Electromagnetic Wave(2))

  • 유권종;김이곤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.677-682
    • /
    • 2000
  • 본 연구는 전동기의 부분방전에 의해 발생되는 전자파를 측정하여 전동기의 열화상태를 진단할 수 있는 진동기 절연열화 진단시스템을 설계하였다. 청장 전동기에서 부분방전에 의한 전자파를 on-line으로 측정하고, 측정된 데이터로부터 정량화된 특징 데이터를 추출한 후 전자파의 평균 에너지 분포를 이용하여 전동기의 절연열화 상태를 판단하는 방법을 제시하였으며, 현장에서 사용 중인 Megger시험과 비교하였다.

  • PDF

XLPE 케이블의 전기적 열화 패턴 분석 (Electrical Degradation Pattern Analysis according to XLPE Cable)

  • 민치현;곽동순;천현권;최진욱;김영석;김선구;김상현
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.114-120
    • /
    • 2008
  • 일반적으로 22.9[kV] 이하의 케이블은 가교폴리에틸렌(XLPE)을 절연체로 사용하고 있다. XLPE내부의 결함으로 인한 사고로 경제적 및 인명피해가 발생한다. 이러한 사고에 대한 처리 기준이 마련이 되어 있지 않아 사고처리의 체계화가 시급히 필요한 실정이다. 본 연구에서는 XLPE 케이블의 사고 요인이 되는 전기적 열화현상에 대한 자료구축을 위하여 XLPE에 곡율반경이 $10[{\mu}m]$인 침천극을 삽입하여 절연파괴, 트리형상 및 연면방전 시료를 제작하였다. 단시간 파괴는 AC 60[Hz]의 전압을 1[kV/sec] 상승하였으며, 장기과전의 경우 AC 60[Hz]의 전압을 12[kV] 및 17[kV]를 인가하여 전기적 열화 특성에 대하여 실험을 하였다.

XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구 (A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation)

  • 강동식;선종호;김위영;이홍식;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.

유동가압성형(TPM)을 이용한 휴대용 유도무기용 연소관 조립체 제작공정연구 (A study on the manufacturing of motor case assembly for K-PSAM propulsion system by Trans. power molding(TPM) process)

  • 정상기;윤남균
    • 한국추진공학회지
    • /
    • 제2권3호
    • /
    • pp.107-115
    • /
    • 1998
  • 복합재료와 금속 튜브 사이의 좁고 긴 원통형 공간을 EPDM(Ethylene propylene dien ter polymer)으로 충전하는 연구를 수행하였다. 휴대용 유도무기의 추진기관을 개발하기 위하여 소형 연소관 조립체를 설계하고 제작하였다. 연소관 조립체는 연소관 금속튜브, 연소관 내열재, 그리고 연소관 단열재로 이루어져 있는데 연소관 내열재는 탄소/페놀릭을 사용하여 롤링 공법으로 제작하였으며 연소관 단열재는 EPDM을 사용하여 TPM 공법으로 제작하였다. EPDM의 조성 선정을 위하여 내열 삭마특성, 열분해특성 실험을 수행하였으며 흐름성, 접착성, 경도측정 등을 통하여 최종 조성을 결정하였다. 연소관 조립체를 제작하기 위한 EPDM 충전을 위하여 TPM 공법을 설계하고 금형과 치구를 제작하였다. 충전된 연소관 조립체는 비파괴검사를 통하여 접착, 기공 등을 검사하여 최종 선정되었다.

  • PDF

전력용 변압기 경년열화와 관련된 DGA 대표가스에 관한 연구 (Representative Dissolved Gases indicating Aging of Power Transformers)

  • 권동진;김용현;주병수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 2017
  • The life management technology becomes important as the failure risk of the aged power transformers increases. Asset management technology, therefore, has been developed to evaluate the remaining life and build replacement strategies of power transformers, which enables an optimal investment decisions based on reliability and economic feasibility. The remaining life assessment technology uses data related to such as installation, operation, maintenance, refurbishment, and disposed history of power transformers. The optimal investment decision additionally uses data related to failure and social costs. To develop the asset management technology in power transformers, it is important to find deterioration parameters directly indicating degradation of power transformers. In this study, 110,000 DGA data during the past 35 years have been analyzed in order to find the deterioration parameters related to the degradation of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, $C_2H_6$), TCG CO, and $CO_2$ were analyzed as deterioration parameters. The origin of the gas was discussed in connection with discharge, overheating and insulation aging.

신경회로망을 이용한 부분방전 메카니즘의 진단과 수명예측 (A Lifetime Prediction and Diagnosis of Partial Discharge Mechanism Using a Neural Network)

  • 이영상;김재환;김성홍;임윤석;장진강;박재준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.910-912
    • /
    • 1998
  • In this paper, we purpose automatic diagnosis in online, as the fundamental study to diagnose the partial discharge mechanism and to predict the lifetime, by introduction a neural network. In the proposed method, Ire use acoustic emission sensing system and calculate a fixed quantity statistic operator by pulse number and amplitude. Using statically operators such as the center of gravity(G) and the gradient of the discharge distribute(C), we analyzed the early stage and the middle stage. the fixed quantity statistic operators are learned by a neural network. The diagnosis of insulation degradation and a lifetime prediction by the early stage time are achieved. On the basis of revealed excellent diagnosis ability through the neural network learning for the patterns during degradation, it was proved that the neural network is appropriate for degradation diagnosis and lifetime prediction in partial discharge.

  • PDF

열발광 특성을 이용한 저밀도 폴리에틸렌의 방사선 열화 검출 (Radiation Degradation Detection of LDPE Using Thermoluminescence Method)

  • 이청;이강원;박정남;임기조;류부형;박영국;강성화;김기엽
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.43-46
    • /
    • 2001
  • Polymers are widely used as insulating materials at various part of power industry. However, electrical properties of these polymers are easily degraded with their working environments, especially radiation areas. In this research, radiation degradation of low density polyethylene (LDPE) used as cable insulation was evaluated with thermoluminescence characteristics. LDPE was irradiated with gamma ray up to 1000 kGy at a dose rate of 5 kGy/hr in the presence of air at room temperature. Each of the irradiated samples were carried out thermoluminescence analysis as a function of temperature. Interrelationships between thermoluminescence and dielectric characteristics and volume resistivity are investigated as well. The results of thermoluminescence analysis showed that those would be significant factors for evaluation of radiation degradation.

  • PDF

원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구 (A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants)

  • 김경조;강석철;구철수;김진호;박재석;주금종;박치승
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.325-330
    • /
    • 2004
  • 원자력발전소에는 여러 종류의 케이블이 전력공급, 감시 및 제어신호의 전달을 위해 열악한 환경하에서 이용되고 있다. 발전소의 안전한 운전을 위해서 이 케이블이 어느 정도 열화 되었는지 확인할 필요가 있다. 특히, 원자력발전소의 수명 연장과 더불어 저압 케이블을 장기간 사용함에 따라서 저압케이블의 열화를 평가하기 위한 방법이 필요하게 되었다 저압케이블의 열화를 측정하는 파라미터로는 주변 온도, 절연재질의 경도, 파단시 연신률(EAB, Elongation At Breaking Point) 등이 있다. 그러나, 온도나 경도를 계측하는 검사는 정량적인 판단기준의 설정이 곤란하고 진단의 정밀도가 낮으며, 부분적으로 샘플링하는 방법은 샘플링되는 케이블에 연결된 부하를 정전시켜야 하고 장소와 시간적인 제약이 있으며, 전기적 측정법은 노화 초기부터 중기까지의 열화정도를 확인하기 어렵다. 본 연구에서는 재료의 열화에 따라서 초음파의 음속이 변화한다는 이론적인 배경(1,2)을 바탕으로 저압 케이블 재료의 열화에 따른 초음파의 음속을 측정하였다. 이를 위해, 원자력발전소에서 사용되는 저압케이블을 가속 열화시켰으며, 저압케이블의 피복재에서 초음파의 음속을 측정할 수 있는 장비를 개발하여, 초음파의 음속측정 후 인장시험을 통해 파단시 연신률을 측정하였다. 파단시 연신률이 증가함에 따라서 음속이 선형적으로 감소하였으며, 초음파의 음속은 열화의 정량적 평가 파라미터로서의 사용 가능성을 확인할 수 있었다.

발전기 권선에서의 신호전송 특성에 관한 연구 (A Study on the Signal Propagation Characteristics of Generator Windings)

  • 황돈하;김진봉;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1299-1303
    • /
    • 1995
  • The detection and measurement of partial discharge activity prevalent in the solid insulating systems of high-voltage generator stator windings has, for many years, been a recognized method of assessing the insulation condition of such systems. Partial discharge activity occurs at sites of degradation within, or at the surface of, stator's insulation systems under high voltage stressing. However, partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. The mode of transmission varies with the signal frequency and is dependant on the geometrical configurations of windings. This paper reports the investigated results of the signal propagation characteristics along the windings when both sinusoidal signals and simulated partial discharge pulses are injected at the various positions of stator windings within the 25 MVA, 11 kV hydro generator. The on-line identification technique of partial discharge location in generator windings is also proposed in this study.

  • PDF