• 제목/요약/키워드: Insulation Degradation

검색결과 230건 처리시간 0.023초

Development of Insulation Degradation Diagnosis System for Electrical Plant

  • Kim, Yi-Gon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제2권1호
    • /
    • pp.33-37
    • /
    • 2002
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defects. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear. it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a electromagnetic wave and acoustic signal to diagnose an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, we design of the neuro-fuzzy model that diagnoses an electrical equipment and is investigated in this paper. Validity of the new method is asserted by numerical simulation.

절연물의열화에 의한 변압기유의 가스분석 (Gas detection of transformer oil according to degradation characteristic of insulation material)

  • 황규현;서호준;이석우;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.574-574
    • /
    • 2005
  • To found out the degradation characteristic of transformer insulation, insulation material was depisited into transformer oil and heated. Due to the thermal stress which added to insulation, the density of carbon dioxide which included in transformer oil was mesured by using the gas density detection equipment of gas sensor and air circulation method. As a result, it didn't match with the transformer supervision standard. But it was found that as thermal stress increased, the density of carbon dioxide propertionally increased.

  • PDF

철도차량 견인전동기의 가속열화수명평가 기술현황 (A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock)

  • 왕종배;김기준;최영찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

PVC 절연재료의 가속열화에 따른 트래킹 특성에 관한 연구 (Study on the Tracking Characteristics Depending on Accelerated Degradation of PVC Insulation Material)

  • 최수길;김시국
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.91-98
    • /
    • 2017
  • 본 논문은 PVC 절연재료의 가속열화에 따른 트래킹 특성에 관한 연구이다. PVC 절연재료를 절연열화 시키기 위해 가속수명 시험방법 중 아레니우스 방정식을 이용한 가속열화실험을 진행하여 등가연수 0년, 10년, 20년, 30년, 40년 된 실험시료를 제작하였다. 그 후 KS C IEC 60112 기준에 의한 트래킹 실험을 진행하였다. 가속열화에 따른 PVC 트래킹 특성 측정 결과 염화암모늄 0.1%를 PVC 절연재료에 투하하였을 때, 트래킹은 발생하지 않았다. 하지만 트래킹 진전과정의 전류파형 및 전압파형을 등가수명 0년에서부터 40년까지 분석한 결과 절연성이 파괴되어 본 재질의 기능성을 갖지 못하는 BDB 구간까지 등가수명 0년을 기준으로 등가수명 10년의 경우 위험성 1.4배 증가, 20년의 경우 위험성 2배 증가, 30년의 경우 위험성 3.5배 증가, 40년의 경우 위험성 7배 증가하는 것으로 나타났다.

XLPE 케이블의 전기트리 열화에 따른 전기적 특성 검토 (A Study on the Electrical Properties of Electrical Tree Degradation in XLPE Cable Insulation)

  • 강동식;선종호;이홍식;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권7호
    • /
    • pp.400-405
    • /
    • 2000
  • In order to improve the reliability of XLPE cables, it is necessary to understand the mechanism of electrical and water tree degradation. Especially, electrical tree initiation and propagation are important in XLPE cable insulation. This paper deals with the changes of electrical properties of XLPE cable insulation with electrical tree degradation. To understand the electrical properties of XLPE insulation, specimens were prepared by 22.9kV distribution cable and made in a type of block. Ogura needles having tip radius of 10${\mu}{\textrm}{m}$ were inserted into each block pieces. AC voltages of 8kV, 10kV and 12kV at 60Hz were applied to needle. We investigated the relationship between electrical properties(PD quantity, tan$\delta$ and DC current) and the growth of electrical tree. The electrical properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed.

  • PDF

전력용 변압기 절연유희 비파괴 진단 시험법 비교연구 (A Comparative Study on the Non-Destructive Diagnostic Methods of the insulation Oils in Power Transformer)

  • 이준호;이동영;최종갑;김재철;곽희로;권태원;한민구
    • 대한전기학회논문지
    • /
    • 제40권8호
    • /
    • pp.799-807
    • /
    • 1991
  • The various degradation phenomena, such as the evolution of gases, tan e, moisture content and total acid number in insulation oils of power transformer have been measured and analyzed as a function of aging temperatures and periods. The insulation oils have been degraded at laboratory in the period of 17, 34, and 72 days. We have also extracted the insulation oils from the working power transformers. The dissolved gases (such as CO, CO2, H2, CH4 C2H2---), tane, moisture content and total acid number in laboratory samples and field samples have been measured and characterized. It has been found that gases increase with degradation temperature and tane increases with total acid number while the moisture content does not increase with tane.

  • PDF

철도차량용 견인전동기의 수명예측 및 절연신뢰성 평가 방법에 관한 연구 (A Study on the Evaluation of Reliability and Expected Life for the Insulation System of Traction Motors in Urban Transit E.M.U)

  • 왕종배;김상걸;이헌돈;오현석;김기준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.449-451
    • /
    • 1999
  • When the traction motor for urban transit E.M.U is driven with VVVF controlled inverter, the insulation degradation factors on the 200 Class insulation system of VPI process are analyzed with considering dielectric, mechanical properties, thermal stability, chemical resistivity and compatibility. A new test method of complex accelerating degradation is proposed to evaluate the insulation reliability and the long-term life including harmonic loss and transient surge stress due to PWM inverter drive.

  • PDF

통계처리와 패턴 인식 기법에 의한 부분방전 해석 (Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique)

  • 변두균;홍진웅
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.

전력용 변압기의 열화에 의해 생성된 부산물의 분석 (Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers)

  • 김재훈;한상옥
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

Tan Delta 측정을 이용한 유침 절연지의 열화특성 분석 (Analysis of Degradation Characteristics for Oil-Paper Insulation using Tan Delta Measurement)

  • 김정태;김우빈
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1518-1523
    • /
    • 2016
  • In this study, in order to understand the degradation characteristics of oil-paper insulation for power transformers and OF cables, tan delta was measured using cable model specimens with long-term accelerated thermal and electrical aging. In addition, to find out the degradation level due to the accelerated aging, tensile strengths of aged papers were measured. As a result, tan ${\delta}$ showed the characteristics of slight decrease at the first stage and then increase with the aging time, which could be analyzed due to the evaporation of remaining moisture and the change of aging rate with time. Also, the trend of tensile strengths with aging temperature and time was appeared to be exponentially decreased and by use of these data equivalent calculated lifetimes and accelerated aging factors were derived for each aging temperatures. After then, tan ${\delta}$ was analyzed with the equivalent operating years. For all different aging temperatures, the aged data were very well fit to the equivalent operating years and it is shown that tan ${\delta}$ was increased with the decrease of tensile strength.