GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

주파수응답함수(FRF)를 이용한 자기 애자의 손상평가 (Damage Evaluation of Porcelain Insulators Using the Frequency Response Function)

  • 최인혁;손주암;오태근;윤영근
    • 한국전기전자재료학회논문지
    • /
    • 제32권2호
    • /
    • pp.122-128
    • /
    • 2019
  • Porcelain insulators have been used mainly for power line fixing and electrical insulation in transmission towers. Porcelain insulators have generally a 30 years desired life, but over 50% exceed their life expectancy. Since the damage to porcelain insulators is usually accompanied by enormous loss of human resource material, their efficient maintenance has emerged as an important issue. In this regard, this study applied a frequency response function (FRF) for integrity assessment of the insulator. The characteristics of the FRF according to damage types were identified and analyzed by the change in natural frequencies, curve shape, attenuation, and Nyquist diagram stability. The results showed significant differences in the FRF according to damage types, which can be used as basic data for the effective integrity assessment of porcelain insulators.

13.8 kV급 발전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in 13.8 kV Generator Stator Windings)

  • 김희동;공태식;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1624-1625
    • /
    • 2011
  • 35년 이상 동안 운전된 2대의 가스터빈 발전기(70 MVA, 13.8 kV) 고정자 권선의 절연상태를 평가하기 위해 정지중 절연진단 시험을 수행하였다. 성극지수, 교류전류, 유전정접 및 부분방전 크기 등을 측정한 결과 모두 양호하여 절연상태가 매우 건전하게 평가되었다. 유전정접이 서서히 증가하는 전압이 부분방전 개시전압과 거의 일치하며, 이 전압은 다시 제1차 전류 급증점 보다는 3 kV정도 낮게 분석되었다. 그리고 발전기 고정자 권선의 부분방전 패턴은 내부방전으로 분석되었다.

  • PDF

실선로 측정 PD 패턴 분석을 통한 154kV 지중송전선로 절연열화 측정 (Assessment of Insulation system for 154kV Underground Transmission Line By Analysing PD Pattern)

  • 박진우;박준우;문경희;박흥석;최경규;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2093_2094
    • /
    • 2009
  • 오늘날 국내 지중선로는 주로 XLPE케이블과 OF케이블로 구성된다. 기존 사용되던 OF케이블의 화재 위험성 및 환경오염 문제 등으로 인해 XLPE케이블의 비중이 점차 높아지고 있지만 XLPE케이블의 경우 운전 중 케이블의 열화나 절연진단 등이 쉽지 않은 점이 문제로 제기되고 있다. 그나마 XLPE케이블에 대한 PD측정은 현재로서는 가장 유용한 케이블 진단기법으로 알려져 있으며 그 활용성과 신뢰성을 높이기 위한 연구가 국내외적으로 계속되고 있는 실정이다. 본 논문에서는 실제 운전 중인 154kV 지중송전선로에 대해 PD측정을 수행하고 그 결과로 취득된 Pattern의 분석을 통해 선로내부에서 PD가 발생하고 있는지 판별하는 과정을 소개하였다.

  • PDF

내연발전기 건전성 판정을 위한 종합 진단결과 고찰 (Inspection of the Diagnosis Report for Life Assessment of Engine Generator)

  • 이영준;주영호
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.96-99
    • /
    • 2010
  • This paper presents evaluating procedure for engine generator operated over 13 years which are usually installed at the island and therefore, isolated to the main distribution line. To decide continual operation of the generator, their diagnosis results should guarantee safety running. So the determination of criteria for continual usage or replacement is essential for economical and reliable maintenance. We present all the courses of evaluating the condition which includes the processes from acquiring basic data to comprehensive determination of generators. All the test was applied to serial number 3 generator in Jodo Engine Power Plant.

지역난방 열배관의 외부작용력 및 되메움재의 안정성 확보에 관한 연구 (The Stability Assessment of Backfill Materials and External Loads in Pre-Insulated District Heating Pipes)

  • 김진만;최봉혁;고현일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.656-661
    • /
    • 2009
  • In this study, theoretical analysis and evaluation tests were performed to assess the pipe stability against compaction equipments and vehicle loads when conventional construction criteria for pre-insulation heating pipes are applied and the alternative material, crushed sand, are used for backfills. The research outcomes shows that (1) the conventional code criteria for pre-insulated heating pipes is well established to support compaction equipments and vehicle loads, (2) the crushed sands as an alternative is usable as backfill materials for pre-insulated heating pipes based on the suitability evaluations of various types of pipes, and (3) the crushed sand agree well with the design consideration of pre-insulated heating pipes construction in the points of economical efficiency and construction criteria.

  • PDF

변압기의 권선변형 검증을 위한 LVI 시험기 개발 (The Development of LVI Tester for WInding Deformation Measurement in Power Transformers)

  • 조국희;김광화;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.251-256
    • /
    • 2000
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetisation current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristics. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformers.

  • PDF

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

하향식 바이오매스 가스화장치의 개발 및 평가 (Development and Assessment of a Downdraft Gasifier for Biomass Gasification)

  • 홍성구;심재훈
    • 한국농공학회논문집
    • /
    • 제50권4호
    • /
    • pp.89-97
    • /
    • 2008
  • A downdraft gasifier was manufactured for biomass gasification. The gasifier was designed based on the principles of gasification presented in previous studies. The pipes of 25mm diameter were used for both supplying air and discharging producer gas. Wood charcoals were mostly used for fuels. The concentration of CO ranged from 25 to 35%, comparable to the values presented in other studies. The temperature outside wall of the gasifier was measured up to $400^{\circ}C$, indicating a great heat loss. When glass wool was cover over the wall, some parts of wire mesh located in the bottom of the reactor were molten down. There were several modifications that should be made in order to improve its efficiency and obtain more stable continuous gasification, including insulation, reduction in pressure loss, durable bottom meshes, the optimum length of reaction part, and safety.

오피스건물 리뉴얼시 패시브 요소적용에 따른 에너지성능 및 PMV 개선에 관한 연구 (Analysis of Energy Performance and PMV Improvement by Application of Passive Factor for Office Building Renewal)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.55-64
    • /
    • 2014
  • This paper presents a case study to investigate the monthly calculation method of ISO 13790 applied for a office building. The energy performance analysis according to improvement of insulation and air permeability of windows in K office buildings is investigated by means of building energy efficiency rating tool ($ECO_2-OD$). The K building energy system is tested experimently by the measurement of PMV(predicted mean vote) for the control of indoor thermal environment and heat transmission coefficient of windows and interior walls respectively, before and after the example K office building is remodeled passively. Therefore, Internet based energy assessment program of energy efficiency rating of office building can be applied as a program for the annual energy requirement and for evaluation of energy savings from the experimental and simulation results.