• 제목/요약/키워드: Insulating resistance

검색결과 171건 처리시간 0.023초

이중절연 자기융착테이프 제조기술 (Manufacturing technology of two-layer self bonding insulating tape)

  • 조용석;이철호;심대섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.890-893
    • /
    • 2001
  • Two-layer self bonding insulating tape consists of butyl rubber(IIR ; Isobutylene-isoprene rubber) adhesive layer and polyethylene protective film. Butyl rubber have inherent characteristics such as resistance to corrosion and water, low temperature flexibility, excellent electrical insulating properties also resistance to environmental effect such as ozone and ultraviolet. Polyethylene film was used for the purpose of good insulating properties and resistance to ozone and ultraviolet. The tape was manufactured using extrusion and calender method.

  • PDF

The Analysis of Heat Transfer through the Multi-layered Wall of the Insulating Package

  • Choi, Seung-Jin
    • 한국포장학회지
    • /
    • 제12권1호
    • /
    • pp.45-53
    • /
    • 2006
  • Thermal insulation is used in a variety of applications to protect temperature sensitive products from thermal damage. Several factors affect the performance of insulation packages. Among these factors, the thermal resistance of the insulating wall is the most important factor to determine the performance of the insulating package. In many cases, insulating wall consists of multi-layered structure and the heat transfer through this structure is a very complex process. In this study, an one-dimensional mathematical model, which includes all of the heat transfer principles covering conduction, convection and radiation in multi-layered structure, were developed. Based on this model, several heat transfer phenomena occurred in the air space between the layer of the insulating wall were investigated. From the simulation results, it was observed that the heat transfer through the air space between the layer were dominated by conduction and radiation and the low emissivity of the surface of each solid layer of the wall can dramatically increase the thermal resistance of the wall. For practical use, an equation was derived for the calculation of the thermal resistance of a multi-layered wall.

  • PDF

파카의 보온성에 따른 착용감에 관한 연구 (The Effects of Parka on Subject Wear Sensation as to Thermal Resistance)

  • 이윤정;이순원
    • 한국의류학회지
    • /
    • 제13권3호
    • /
    • pp.295-303
    • /
    • 1989
  • This study is to measure the thermal resistance of 7 types of Parka of different materials with thermal manikin and to compare their effects on physiological responses & subjective wear sensations. Following are the results obtained from the experiments 1) From the thermal manikin experiment, i) As an outer layer, although not significant, water proof fabric was warmer than water proof-vapor permeable fabric. ii) In case of insulating material, down was better for thermal resistance than polyester wadding of the same thickness. Moreover, as the down was thicker, it had more efficiency in thermal resistance. However, the marginal efficiency of thickness was found to be decreasing. 2) From the male-subject experiments, i) Chest temperature, mean skin temperature & microclimate temperature showed the same results on thermal resistance as those of the thermal manikin experiment. ii) Only during rest periods, there was a significant difference among 5 insulating materials in the sense of microclimate humidity. The almost same conclusion was obtained from the above experiments. Even the outer layer did not significantly affect thermal resistance & subjective wear sensation, insulating materials had a significant influence upon them. But in case of 3.5 cm down, it gave less comfortable than that of the thinner. Therefore the optional one for the best comfort & thermal resistance among 7 combinatins is the outer layer of water proff-vapor permeable & insulating material of 2.1 cm down.

  • PDF

배연용 축류팬의 내열 신뢰성 향상 (Improvement of the Heat Resistance Reliability of an Axial Smoke Exhaust Fan)

  • 허진혁;허기무;문승재;이재헌
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.656-662
    • /
    • 2009
  • In this paper, the heat resistance reliability of an axial smoke exhaust fan was investigated. An axial smoke exhaust fan should be capable of operating at $250^{\circ}C$ for 2 hours. The heat resistance reliability was evaluated by the heat resistance reliability test. A B10 life with a 90% confidence level was estimated to be about 48 minute. The failure occurred in the motor due to high temperature. The main failure mechanisms of the motor were melting of bond and insulating paper and burning of insulating materials in the coil. The heat resistance reliability was improved by changing the way to unite the core and the coil and by replacing the insulating paper and the insulating materials of the coil. A B10 life with a 90% confidence level of a modified axial smoke exhaust fan was estimated to be over 120 minute.

친환경 GIS Spacer용, 이종 무기물 절연소재의 혼합비 최적화를 위한 부분방전 저항성 특성 연구 (A Study on the Partial Discharge Resistance Characteristic for Optimizing the Mixing Ratio of Heterogeneous Inorganic Insulated Materials for Environmentally Friendly GIS Spacer)

  • 박재준
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1189-1196
    • /
    • 2018
  • 7 type composites (40, 45, 50, 55, 60, 65, and 70 wt.%)were prepared for the environmentally friendly GIS Spacer. Five kinds of samples were prepared for optimization of the filler content ratio (MS: MA = 1: 9, 3: 7, 5: 5, 7: 3, 9: 1) of epoxy / microsilica and microalumina. As a result of evaluation of the partial discharge resistance characteristic, surface erosion is generally slowed down as the fill amount of micro silica is increased. Also, partial discharge resistance characteristics for the development of insulating materials with optimal mixing ratios of heterologous showed a higher partial resistance of discharge and a decrease in erosion, as the filler content ratio of micro silica was larger. In the future, various researches such as electrical, mechanical, and thermal studies will be needed to develop insulating materials that can commercialize power devices in environmentally friendly insulating gas.

고주파 마그네트론 스퍼터링으로 제조한 SiO$_2$ 절연박막의 구조분석 및 절연저항에 관한 연구 (Insulation Properties and Microstructure of SiO$_2$ Film Prepared by rf Magnetron Sputtering)

  • 박태순;이성래
    • 한국표면공학회지
    • /
    • 제35권2호
    • /
    • pp.113-121
    • /
    • 2002
  • We have investigated insulating properties of $SiO_2$ interlayer for the thin film strain gauge, which were prepared by RF magnetron sputtering method in various deposition conditions, such as Ar pressure, gas flow rates and sputtering gases. SEM, AFM and FT-IR techniques were used to analyze its structures and composition. As the Ar pressure and the flow rate increased, the insulating interlayer showed low insulating resistance due to its porous structure and defects. Oxygen deficiency in $SiO_2$ was decreased as fabricated by hydrogen reactive sputtering. We could enhance the surface mobility of sputtered adatoms by using Ar/$H_2$ sputtering gas and obtain a good surface roughness and insulating property. The optimum insulating resistance of 9.22 G$\Omega$ was obtained in Ar/30% $H_2$ mixed gas, flow rate 10sccm, and 1mTorr.

누전차단기 절연재료의 소손 특성에 관한 연구 (A Study on the Damage by Burning Characteristics of Insulating Materials of RCD)

  • 이춘하;김시국;옥경재;지승욱
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.62-66
    • /
    • 2009
  • 본 연구는 국내에서 사용되고 있는 누전차단기 외함 절연재료의 소손 특성에 대하여 연구하였다. 시료는 3개 제조사의 누전차단기 외함 절연재료를 사용하였으며, 시료의 열분해특성, 연소특성, 트래킹 특성 등을 비교 분석하였다. 열분해특성은 TGA를 사용하였으며, 연소특성은 ISO5660(Fire Tests - Reaction to Fire, part 1)을 만족하는 Mass Loss Calorimeter(FTT 사)를 사용하였고, 트래킹 특성은 고체 절연재료의 내트래킹 및 비교트래킹 지수를 측정하는 실험인 KSC IEC 60112.의 기준에 따라 분석하였다. 연구결과 A제조사의 경우 내트래킹성이 가장 우수하였고, B제조사의 경우 내트래킹성이 가장 낮은 반면 $350^{\circ}C$ 이상의 고온에서 열안정성이 가장 우수하였으며, C제조사의 경우 $400^{\circ}C$ 이하의 온도에서 열안정성이 가장 우수한 것을 알 수 있었다.

Experimental study on shear, tensile, and compression behaviors of composite insulated concrete sandwich wall

  • Zhang, Xiaomeng;Zhang, Xueyong;Liu, Wenting;Li, Zheng;Zhang, Xiaowei;Zhou, Yilun
    • Advances in concrete construction
    • /
    • 제11권1호
    • /
    • pp.33-43
    • /
    • 2021
  • A new type of composite insulated concrete sandwich wall (ICS-wall), which is composed of a triangle truss steel wire network, an insulating layer, and internal and external concrete layers, is proposed. To study the mechanical properties of this new ICS-wall, tensile, compression, and shearing tests were performed on 22 specimens and tensile strength and corrosion resistance tests on 6 triangle truss joints. The variables in these tests mainly include the insulating plate material, the thickness of the insulating plate, the vertical distance of the triangle truss framework, the triangle truss layout, and the connecting mode between the triangle truss and wall and the material of the triangle truss. Moreover, the failure mode, mechanical properties, and bearing capacity of the wall under tensile, shearing, and compression conditions were analyzed. Research results demonstrate that the concrete and insulating layer of the ICS-wall are pulling out, which is the main failure mode under tensile conditions. The ICS-wall, which uses a graphite polystyrene plate as the insulating layer, shows better tensile properties than the wall with an ordinary polystyrene plate. The tensile strength and bearing capacity of the wall can be improved effectively by strengthening the triangle truss connection and shortening the vertical distances of the triangle truss. The compression capacity of the wall is mainly determined by the compression capacity of concrete, and the bonding strength between the wall and the insulating plate is the main influencing factor of the shearing capacity of the wall. According to the tensile strength and corrosion resistance tests of Austenitic stainless steel, the bearing capacity of the triangle truss does not decrease after corrosion, indicating good corrosion resistance.

Effect of ceramic powder addition on the insulating properties of polymer layer prepared by dip coating method

  • Kim, S.Y.;Lee, J.B.;Kwon, B.G.;Hong, G.W.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.14-18
    • /
    • 2014
  • The mechanical, electrical and thermal characteristics of insulating materials may significantly affect the performance and reliability of electrical devices using superconductors. General method to provide insulating layer between coated conductors is wrapping coated conductor with Kapton tape. But uniform and compact wrapping without failure or delamination in whole coverage for long length conductor is not a simple task and need careful control. Coating of insulating layer directly on coated conductor is desirable for providing compact insulating layer rather than wrapping insulating layers around conductor. Ceramic added polymer has been widely used as an insulating material for electric machine because of its good electrical insulating properties as well as excellent heat resistance and fairy good mechanical properties. The insulating layer of coated conductor should have high breakdown voltage and possesses suitable mechanical strength and maintain adhesiveness at the cryogenic temperature where it is used and withstand stress from thermal cycling. The insulating and mechanical properties of polymer can be improved by adding functional filler. In this study, insulating layer has been made by adding ceramic particles such as $SiO_2$ to a polymer resin. The size, amount and morphology of added ceramic powder was controlled and their effect on dielectric property of the final composite was measured and discussed for optimum composite fabrication.

크랙저항성(抵抗性)과 단열성(斷熱性)을 향상(向上)시킨 EVA칩 첨가 기포콘크리트의 려공법(旅工法) 연구(硏究) (A Study on Method of Construction for Foamed Concrete adding EVA Chip that improves the Resistance of Cracking and Capability of Insulating)

  • 이종식;안정찬;이종학
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.5-9
    • /
    • 2007
  • The construction method for Foamed-Concrete has not been important due to following process of construction work. However, according to the code about enhance of energy saving design policy and impact noise, noised isolation has been used in construction site so that the resistance for cracking and capability for insulating of Foamed-Concrete has been required. Therefore, new alternatives are demanded. Optimum mixing design, which can get the improvement of insulation and resistance of crack for Foamed-Concrete adding EVA chip, was derived and also the device, applying to construction site, was invented to equalize quality. This device can measure quantity of all input and placement, and show up the sum of placement and mixing design on a touch screen. This valuable construction method is friendly environment and recycling method because of using EVA chip, by-product of an EVA insole scrap burned or embedded, as a light-weight aggregate.

  • PDF