• Title/Summary/Keyword: Insulating concrete

Search Result 71, Processing Time 0.027 seconds

Selecting optimized concrete structure by Analytic Hierarchy Process (AHP)

  • Ebrahimi, Morteza;Hedayat, Amir Ahmad;Fakhrabadi, Hamed
    • Computers and Concrete
    • /
    • v.22 no.3
    • /
    • pp.327-336
    • /
    • 2018
  • Increase in population and its daily increasing in our today society results in an increase in housing demand while traditional methods are not applicable. The project preparation and realization processes, based on theoretical and empirical studies, a creation of goods, services, and technologies, are the most important human activities. Selection of effective technological systems in construction is a complex multi-criteria decision-making task. Many decision-makers refuse innovations once faced with similar difficulties. Therefore, using modern materials and methods in this industry is necessary. Modern methods increase quality and construction speed in addition to decrease energy consumption and costs. One of the problems in the way of any project is selecting construction system compatible with the project needs and characteristics. In the present research, different concrete structures such as common reinforced concrete (RC) structure, prefabricated, Insulating Concrete Formwork (ICF), 3D Panel and Tunnel Concrete Formwork (TCF) for buildings with limited floors in Iran are studied and compared from the viewpoint of different criteria like cost, time, applicability and technical characteristics with industrialization approach. Therefore, some questionnaires filled out by construction industry experts in order to compare criteria and sub-criteria in addition to evaluation of optimized structural systems. Then, results of the questionnaires ranked by Analytic Hierarchy Process (AHP) and the most effective alternative selected. The AHP results show that 3D Panel system 36.5%, ICF 21.7%, TCF 19.03%, prefabricated system 13.3% and common RC system 9.3% are the most and the least efficient systems respectively.

Temperature History of Slab Concrete Depending on Insulation Curing Method in Cold Weather Concreting (한중시공시 단열양생방법 변화에 따른 슬래브 콘크리트의 온도이력 특성)

  • Kim Jong-Back;Lim Choon-Goun;Park Koo-Byoung;Kim Seoung-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.17-20
    • /
    • 2005
  • This paper reported the temperature history of concrete placed at deck plate slab under cold climate condition by varying with surface insulating type. No curing sheet and simple insulation curing including non-woven fabric, double layer bubble sheet, the combination of double layer bubble sheet and non-woven fabric dropped temperature below zero within 24 hours, which caused frost damage at early age. On the other hand, the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam maintained minimum temperature above $4^{\circ}C\;and\;8^{\circ}C$, respectively. Based on core test results compressive strength of concrete with the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam was higher than those with other curing method due to good insulation effect.

  • PDF

Strength Characteristics according to the mixed CaO/$SiO_2$ Ratio to Autoclaved Aerated Concrete(AAC) used on the Exterior Panel in Buildings (건물 외벽 패널용 경량기포콘크리트(AAC)의 CaO/$SiO_2$ 혼합비에 따른 강도 특성 평가)

  • Kim, Young-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.3
    • /
    • pp.35-42
    • /
    • 2011
  • The exterior system of buildings, which is the typical curtain wall, has been made with glass and metal. Theses materials, however, have weaknesses such as inadequate insulating quality, short durability, combustibility and toxic substance. On the other hand, Autoclaved Aerated Concrete(AAC) or Autoclaved Lightweight Concrete(ALC) possess the great energy efficiency and the superb insulating quality as substitute of existing exterior system materials. In this research, strength characteristics and bubble dispersion of hydrothermal synthesis process of AAC based on CaO/$SiO_2$(C/S) ratio are analyzed. C/S ratio is determinated and bubble distribution and compressive strength are studied through the test of varied water-to-solid mineral ratio(W/S). In hydrothermal synthesis program, final C/S ratio is determined as 0.7 consider of the manufacturing process and hydrothermal synthesis is done at $180^{\circ}C$ for 7 hours. The analysis shows slurry has about 2,300cP viscosity and 0.56 specific gravity therefore it is expected AAC has the appropriate facility in the manufacturing process and Hydrates of AAC's Expansion.

Strength and Thermal Properties of Concrete for Replacement Fine Aggregate with Biochar (잔골재를 바이오차로 치환한 콘크리트의 강도와 열적 특성)

  • Kyoung-Chul Kim;Kwang-Mo Lim;Min-Su Son;Young-Seok Kim;Kyung-Taek Koh
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.425-432
    • /
    • 2023
  • In this study, we aim to develop a carbon-reducing concrete technology by incorporating biochar. Performance evaluation experiments were conducted on concrete mixtures containing biochar with insulating and carbon-capturing properties, which are essential for key infrastructure sectors such as construction and tunnels. Concrete mixtures were designed with different biochar incorporation rates of 0 %, 5 %, 10 %, 15 %, and 20 %, as w ell as w ater-to-binder ratios of 0.25, 0.30, 0.35, and 0.40. To assess the physical properties of each mixture, unit weight, total porosity, and permeability were measured, while mechanical properties were determined through the measurement of concrete compressive and flexural strengths. Key factors for enhancing the insulating effect of carbon-reducing concrete containing biochar were identified through regression analysis, indicating a close correlation among biochar incorporation rate, unit weight, concrete strength, and thermal conductivity. It is anticipated that it can be utilized as an insulating material to enhance thermal performance in northern regions with severe winter climates.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

An Experimental Study on the Strength Characteristic Improvement of the Autoclaved Lightweight Concrete(ALC) containing Quicklime and Silica Fume (생석회와 실리카퓸을 활용한 경량기포콘크리트(ALC)의 강도특성 개선을 위한 실험적 연구)

  • Kim, Young-Ho;Song, Hun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.4
    • /
    • pp.21-27
    • /
    • 2011
  • These materials in architecturally glass or metal have weaknesses such as inadequate insulating quality, combustibility and toxic gases in fires substance. However, Autoclaved Lightweight Concrete(ALC) has excellent thermal insulation properties and seem to possess the superb insulating quality as substitute of existing exterior materials. This research is to compare experimentally to the kind of the strength properties of ALC materials which mixed with blast furnace slag pounder and silica fume. For the purpose of increasing the strength, the plastic states of ALC evaluate the physical characteristics as microstructure and strength according to various specific gravity. According to the quicklime quantity the compressive strength is proportionate depend on the absolute dried specific gravity. When not putting in 10% quicklime, the compressive strength appeared most lowly with 14.0MPa. When putting in the quicklime, the strength appeared higher with 15.1MPa. And strength of specimen containing 2.25% silica fume is 15.6MPa increased 10.3% than reference specimen 14.0MPa.

A Study on Monolithic Expression Characteristics of Concrete Buildings With focus on insulated lightweight aggregate concrete (콘크리트 건축물의 모놀리스적 표현특성에 관한 연구 단열경량골재콘크리트를 중심으로)

  • Won, Kyoung-Sop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.363-373
    • /
    • 2018
  • In today's diversified society, it is hard to know which building style represents the architectural style of the time. The simplicity found in monolithic-style buildings forms a symmetrical point with fairly complex structure, and its value can be acknowledged. This study analyzes buildings made of insulating lightweight aggregate concrete in the early 21st century, defines the concept of monolithic expression, and examines how these characteristics are expressed in the space, forms, and structural methods in construction. Unlike a multi-layered exterior wall system, which features multiple layers composed of a variety of materials, the exterior walls built with insulating lightweight aggregate concrete comes in a lump form with a mold form that is tightly filled with concrete as a single material and is monolithic. This is attributed to the creation of spaces characterized by the homogeneity of inner and outer spaces with the use of the same material, continuity of the surface as solidity, spatial characteristics of the stereotomic construction, expression of materiality with the use of exposed concrete, and the contrast of the lump and the space. This not only reveals formal characteristics that expose a discourse about monolithic architecture in contemporary architecture but also provide an opportunity to extend the range of discussion to structures and materials and even to their effects on space.

Growth of Grass and Control of temperature of Planting Concrete for Roof Using Recycled Aggregate (재생골재를 이용한 옥상식재용 콘크리트의 잔디생육과 열환경조정효과)

  • 이상태;김정진;황정하;김진선;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.237-242
    • /
    • 2001
  • The objective of this study is to investigate growth of grass planted with planting concrete using recycled aggregste. Planting concrete blocks are constructed on the roof of existing building. Temperature variation according to planting concrete method are also investigate. According to test results, it shows that grass grows very well under planting concrete method. When planting concrete method is applied, it brings about temperature reducing effects about 1~$2^{\circ}C$ at inner part of the buildings at cooling required period compared to that with existing roof, and at heating required period temperature insulating effects about 2~$4^{\circ}C$.

  • PDF

An experimental study on the difference of temperature and strength according to member size for cold weather concrete (한중콘크리트의 부재 단면별 온도범위와 강도변화특성에 관한 실험적 연구)

  • Kim, Meyong-Won;Park, Kwang-Su;Cho, Young-Kweon;Lee, Joon-Gu;Kim, Kwan-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.421-424
    • /
    • 2005
  • Discusses the results of an investigation of the relationship between maturity in field-cured specimens and that from the thinner dimension structure to thick, particularly at cold weather concrete. Tests were carried out on two different concrete mixes with 28 day compressive strengths ranging approximately 30MPa. Ready-mixed concrete was used, and test specimens were the conventional field-cured 10$\times$20cm concrete cylinder with insulating materials and without them, and test structures were the thinner(width 20cm), the general(width 40cm), the thick dimension(width 60cm), respectively. Tests were performed at age of 3, 7, 14, 28 day. Analyses of test results show that the maturity of concrete for require compressive strength was suggested to be keep higher than $164D^{circ}D$ until at least from 8day to 10day

  • PDF

Zero-Crack Construction on the Fundamental Mass Concrete Using Double Bubble Sheets and Applying Low Heat Mixture (저발열 배합 및 이중버블시트에 의한 기초 매트 매스 콘크리트의 무균열 시공)

  • Park, Yong-Kyu;Song, Sung-Bin;Baek, Byung-Hoon;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.5-8
    • /
    • 2006
  • This study investigates the field application, Songdo the # 1st WORLD, on zero-crack construction of the fundamental mass concrete using double bubble sheets and applying low heat mixture. Experimental results of hydration heat analysis showed that crack modulus of concrete incorporating 20% of blast furnace slag cement was 1.0 in 120 hours, representing 50% probability of crack occurrence, thus requiring additional measures. As for a curing method, a specimen insulating two layers of vinyl chloride+double bubble sheets exhibited only $16.5^{\circ}C$ difference between upper and lower sections, and it also showed favorable workability as well as competitive economic side. Therefore it was determined to use it for curing method in this field. For the curing results of practical field, using 2 layers of vinyl chloride+double bubble sheets and applying low heat mixture on the fundamental mass concrete in 3A residential building exhibited less than only $15^{\circ}C$ difference between surface and center section of that in 5 days elapse and less than $20^{\circ}C$ in 9 days. This means that the crack by hydration heat was prevented, and other fields structures also resisted the plastic shrinkage by insulating the vinyl, sinking crack by second temping, even drying shrinkage by the mixture of low unit water. Therefore the crack on the placement has not been found so far, since the construction was started before 6 month.

  • PDF