• Title/Summary/Keyword: Insulating concrete

Search Result 71, Processing Time 0.021 seconds

A Fundamental Study on the Effectiveness of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집에 의한 한중콘크리트 시공의 효율화에 관한 기초적 연구)

  • Kim, Kyoung-Min;Won, Cheol;Kim, Gi-Cheol;Oh, Sun-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.617-622
    • /
    • 2001
  • This paper presents the effectiveness of cold weather concreting by applying both anti-freeze agent and insulating forms developed through previous study investigating insulating effects on the concrete and the strength gain. According to test results, in $-10^{\circ}C$ of air temperature, when euroforms are applied, the temperature of plain concrete drops below $0^{\circ}C$ and maintains its temperature during early 24 hours. However, when insulating forms are applied, the temperature of concrete keeps 8~$13^{\circ}C$ during first 24 hours. Insulating forms has better performance on insulating effects than existing euroforms. Concrete containing anti-freeze agent shows temperature rising effects about $1^{\circ}C$ compared to plain concrete. Strength gain of core concrete shows higher when insulating forms is applied.

  • PDF

An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

An Experiment on the Structure Application of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 구조체 적용 실험)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.21-26
    • /
    • 2002
  • This paper is intended to verify the efficiency of anti-freeze agent and insulating form by analyzing the temperature history and the property of strength-increase about the concrete that is placed in the insulating form and normal form, using new type anti-freeze agent in batcher plant According to the results about the temperature history, while the lowest temperature shows 3$^{\circ}C$ in case of normal concrete + euroform, 4$^{\circ}C$ in case of normal concrete + insulating form, it shows 6$^{\circ}C$ in anti-freeze agent + the insulating form, so the effect is most favorable. The compressive strength with mixing anti-freeze agent or not, shows high in order of standard curing, structure-managing and open air-placed specimen and the concrete mixing anti-freeze agent shows the highest compressive strength-increase.

  • PDF

A Fundamental Study on the Effectiveness of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (Focused on the Slab) (내한제 및 단열거푸집에 의한 한중콘크리트 시공의 효율화에 관한 기초적 연구 (슬래브를 중심으로))

  • Kim, Kyoung-Min;Won, Cheol;Hong, Sang-Hee;Kim, Gi-Cheol;Oh, Sun-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.913-918
    • /
    • 2001
  • This paper investigates insulating effects and strength properties of concrete under cold climate carrying out the experiment with insulating forms on the slab member. According to test results, under $-10^{\circ}C$ of outer temperature, the surface of concrete exposed to outer temperature goes below zero after 10hours since exposed. And, the surface of concrete covered with vinyl and blanket goes below zero after 42hours. However, the surface of concrete covered with insulating materials such as polystyrene foam does not drop below zero until 55hours. And, according to coring sample strength test, compressive strength cured with insulation shows much higher strength than no insulation curing condition and vinyl and blanket curing condition.

  • PDF

Experimental study on shear, tensile, and compression behaviors of composite insulated concrete sandwich wall

  • Zhang, Xiaomeng;Zhang, Xueyong;Liu, Wenting;Li, Zheng;Zhang, Xiaowei;Zhou, Yilun
    • Advances in concrete construction
    • /
    • v.11 no.1
    • /
    • pp.33-43
    • /
    • 2021
  • A new type of composite insulated concrete sandwich wall (ICS-wall), which is composed of a triangle truss steel wire network, an insulating layer, and internal and external concrete layers, is proposed. To study the mechanical properties of this new ICS-wall, tensile, compression, and shearing tests were performed on 22 specimens and tensile strength and corrosion resistance tests on 6 triangle truss joints. The variables in these tests mainly include the insulating plate material, the thickness of the insulating plate, the vertical distance of the triangle truss framework, the triangle truss layout, and the connecting mode between the triangle truss and wall and the material of the triangle truss. Moreover, the failure mode, mechanical properties, and bearing capacity of the wall under tensile, shearing, and compression conditions were analyzed. Research results demonstrate that the concrete and insulating layer of the ICS-wall are pulling out, which is the main failure mode under tensile conditions. The ICS-wall, which uses a graphite polystyrene plate as the insulating layer, shows better tensile properties than the wall with an ordinary polystyrene plate. The tensile strength and bearing capacity of the wall can be improved effectively by strengthening the triangle truss connection and shortening the vertical distances of the triangle truss. The compression capacity of the wall is mainly determined by the compression capacity of concrete, and the bonding strength between the wall and the insulating plate is the main influencing factor of the shearing capacity of the wall. According to the tensile strength and corrosion resistance tests of Austenitic stainless steel, the bearing capacity of the triangle truss does not decrease after corrosion, indicating good corrosion resistance.

A study on thermal properties of concrete using gang form coated with polyurethane (폴리우레탄 폼을 도포한 갱폼사용에 따른 콘크리트 온도이력특성)

  • Nam, Kyung-Yong;Won, Joon-Yuen;Kang, In-Seon;Jeon, Pan-Keun;Lee, Young-Do;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.11-12
    • /
    • 2011
  • This study examine Effect of Change of Compressive Strength of Concrete Members with Insulating Gang form on Temperature History of Concrete Positions. Test show, insulating gang forms differences and gang forms have 10℃ on peak point temperature of surface and Center if temperature history have 24Mpa by change of compressive strength. In addition, there have 14℃(16℃) on peak point temperature of surface and Center if temperature history have 40(60)Mpa. Therefore, insulating gang forms have an effect insulating performance.

  • PDF

Comparison of Temperature History of Concrete with the Combination of the Various Surface Curing Sheets at Hot Weather Condition (표면 양생시트 조합에 의한 서중콘크리트 표면온도 이력 비교)

  • Lee, Ju-Suck;Kim, Jong-Back;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.87-90
    • /
    • 2006
  • This study investigates the temperature history of slab mock-up specimens for hot weather concreting applying various surface insulating methods, in order to improve concrete quality at hot weather condition. Test showed that the use of insulating blanket or a bubble sheet on upper section of slab prevented from abrupt increase of temperature and vaporization of moisture during early curing at hot weather circumstance. In addition, it secured higher strength at early age. Therefore it is concluded that concrete construction insulating with the bubble sheet will reduce the plastic and drying shrinkage as well as improve strength at early age, thus securing concrete duality.

  • PDF

Development of Forms for Cold Weather Concrete by Combination of Insulation (단열재 조합에 의한 한중콘크리트용 거푸집 개발)

  • Han, Cheon-Goo;Oh, Seon-Kyo;Sin, Dong-An;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.392-399
    • /
    • 2003
  • This paper discusses the validities of insulating curing of cold weather concreting at early stage by applying insulation forms. Tests were carried out using modified insulating form combining existing insulating form and various other insulations in order to develop improved insulation form. Temperature history of concrete using various insulating forms and insulation was measured to determine most effective combination of insulting form. According to results, as for the wall form, under the curing temperature of $-10^{\circ}C$, the temperature of concrete using Euro form drops sharply before 24 hours and lasts below $0^{\circ}C$ for 7 hours. The temperature of concrete using the form combining Polypropylene panel, styrofoam and plywood panel keep above $0^{\circ}C$. And, it is confirmed that the form mentioned above has a favorable effects on enhancing strength development of concrete and the cost to make the forms shows more reasonable than that of existing forms. However, as for the combination methods of insulation form for slab, which is composed of insulating form at the bottom of slab and various surface curing materials at the top of slab, in case of exposed condition at the top of slab, temperature history of concrete goes below $0^{\circ}C$ after 10 hours. In case of the combination of vinyl sheet and curing blanket, it drops below $0^{\circ}C$ after 42 hours. However, in case of the combination of vinyl, styrofoam and curing blanket, it does not go below $0^{\circ}C$ until 55 hours. Accordingly, compared to the case of exposure and the combination of vinyl and curing blanket, it indicates that the combination mentioned above has more effective insulating performance.

Field Construction Applying the Insulating Method of Moderate-Cold Weather Concreting Using Double Bubble Sheets (2중 버블시트를 이용한 한랭기 콘크리트의 단열양생공법 현장적용)

  • Kim, Jong;Kim, Jong-Back;Jeon, Chung-Keun;Shin, Dong-An;Oh, Seon-Gyo;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.29-32
    • /
    • 2006
  • Experimental test results of field construction, Cheongju University Educational Liberal Art Building, applying the insulating curing method on slab concrete showed that the quality of concrete in fresh and hardened state satisfied all target values. Temperature history of slab concrete in A and B area secured more than $7.8{\sim}9.2^{\circ}C$ higher than outside atmosphere. After completing certain curing period of time on the surface of the structure, crack occurrence was not found. It is concluded that the preventing vaporization of moisture by the insulating curing method reduces plastic and drying shrinkage as welt as improves durability.

  • PDF

Study on Improvement of Thermal Environment by Green Roof Systems on RC Building - utilization of solar insulating block and the grass - (옥상녹화에 따른 콘크리트 건축물의 열환경 개선효과 -일사차폐블록과 잔디를 대상으로-)

  • Park, Chanpil;Furukawa, Nobuhisa
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Caused on the excessive heat accumulation of concrete material, the indoor thermal environment of reinforced concrete building is so bad in Okinawa. As the interruption of solar radiation could be one of the methods to improve it, the purpose of this study is to find out the effect of adopting solar radiation interrupting materials -Solar insulating block, Grass, and both of them- for the improvement of thermal environment. As the result, it was found that grass on the solar insulating block which has an air layer obviously improved the indoor thermal environment of RC building which was applied to. And it was found that the systems have an effectuality on heat island phenomenon simultaneously. It could be proposed as a good system which improve the indoor thermal environment of the existent houses.