• 제목/요약/키워드: Insulating characteristics

검색결과 519건 처리시간 0.022초

식물성절연유의 가속열화에 따른 장기적 안정성 분석 (Research of Accelerated Aging According to Long-term Stability of Vegetable Oil)

  • 최순호;허창수
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1148-1152
    • /
    • 2012
  • The vegetable-based insulating oils are substitutes for mineral oils in oil-filled transformer. The important properties of vegetable insulating oil is their higher flash/fire point and biodegradability than conventional mineral oils. The large oil-filled transformer eliminate the risk of explosion and fire should the transformer fail and oil ignite owing to high flash/fire point of vegetable insulating oil. In addition, higher biodegradability of vegetable insulating oils can let the oil spill damage reduced. In this experiment, the real oil-filled transformers using mineral oil and vegetable oil have accelerated aging. After working on the 100% accelerated aging experiment were conducted comparing the transformer. The hottest-spot temperature using thermal coefficients were calculated to determin the degree of accelerated aging. As a result, apply mineral oil transformer in accordance with the accelerated aging life come to an end. In contrast, vegetable insulating oils showed the opposite characteristics. Vegetable insulating oil compared to the mineral oil are found to be an long life. As a result, the vegetable oil has a long-term stability.

UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정 (Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제35권3호
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

테라헤르츠파 분광법에 의한 절연유 특성 평가 (Evaluation of Insulating Oil by Terahertz Time Domain Spectroscopy)

  • 김근주;전석기;선종호;진윤식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권8호
    • /
    • pp.411-416
    • /
    • 2006
  • A new method on the evaluation of insulation oil was proposed. Terahertz time-domain spectroscopy (THz-TDS) was applied to investigate the properties of the insulating oil. For the diagnostics of oil degradation, three kinds of oils have been analyzed by THz-TDS. The degraded oil showed different optical and electrical constants compared with a new one. Generally, the power absorption coefficient, the refractive index, the dielectric constant and loss $tan{\delta}$ of the oil increase as the aging of insulating oil proceed. And the characteristics of two kind of insulation oil, 1-4 and 7-4, was compared in terahertz spectral region. Difference in refractive index and complex dielectric constant has been observed between the samples. The results of this study suggest that THz-TDS is a promising new means for evaluating degradation and identification of insulating oil.

내부 보이드가 절연 바니시의 전기적 특성에 미치는 영향 (Effect of Electrical Properties in the insulating Varnish due to Internal Voids)

  • 박형준;허연;김원종;윤헌주;신종열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.472-475
    • /
    • 2003
  • In this paper, insulating varnish has been used for field magnet and armature impregnated insulating material of electric locomotive and traction motor. When it was duplicated coating, it could be accuse internal void, and which could change electrical characteristics. We used to boundary elemental method of simulation tool, and improved optimal insulating design of insulating varnish according to measuring electric distribution in void of specimen.

  • PDF

열절연 구조를 이용한 가변광감쇠기의 특성에 관한 연구 (A Study on the Characteristics of Variable Optical Attenuators Using Heat Insulating Structures)

  • 양동평;김정근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(1)
    • /
    • pp.321-324
    • /
    • 2004
  • In this paper, attenuation characteristics of silica-based variable optical attenuator (VOA) with heat insulating structures are investigated by variations of structural parameters and heating power at wavelength 1.55${\mu}m$. The characteristics of power dissipation and attenuation at this VOA was optimized in terms of heating insulating width, under-cladding height and over-cladding height. The optimized maximum attenuation of this VOA was achieved about 31dB at heating power 150mW.

  • PDF

Analysis of Insulating Characteristics of Cl2-He Mixture Gases in Gas Discharges

  • Tuan, Do Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1734-1737
    • /
    • 2015
  • Insulating characteristics of Cl2-He mixture gases in gas discharges were analysed to evaluate ability of these gases for using in medium voltage and many industries. These are electron transport coefficients, which are the electron drift velocity, density-normalized longitudinal diffusion coefficient, and density-normalized effective ionization coefficient, in Cl2-He mixtures. A two-term approximation of the Boltzmann equation was used to calculate the electron transport coefficients for the first time over a wide range of E/N (ratio of the electric field E to the neutral number density N). The limiting field strength values of E/N, (E/N)lim, for these binary gas mixtures were also derived and compared with those of the pure SF6 gas.

XLPE 케이블 접속함에 있어서 이종계면의 절연 및 유전특성 (Dielectric and Breakdown Characteristics of Interfaces in XLPE Cable Accessories)

  • 황보승;전승익;이광철;오응종;박대희;박민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.216-218
    • /
    • 1993
  • XLPE cable accessories are mainly consisted by the combination of various insulating materials such as XLPE cable insulation, rubber, epoxy, etc. It is important to investigate the dielectric and breakdown characteristics of the interfaces between various insulating materials. In this paper, by testing and measuring the breakdown strength, dissipation factor, volume and surface resistance and conduction current of specimens, we report the dielectric and breakdown characteristics of interfaces between various insulating materials.

  • PDF

바니쉬 함침이 절연지에 미치는 영향 (Electric Characteristics on the Insulating Paper with Varnish-Impregnant)

  • 김필환;김주한;이원영;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.180-182
    • /
    • 2004
  • We have investigated characteristics of varnish and oil impregnant. When transformers are manufactured with some moisture and varnish impregnant not entirely dried, those should be caused by factors that deteriorate the electrical or mechanical property after installation. Therefore, in this study we experienced moisture content of the new insulating paper and the varnish impregnant paper in the ratio of time for confirming factors that deteriorate the paper characteristics. Besides, we investigated a property study that was experienced the value of dielectric strength and tensile strength as no serviced insulating samples of transformer.

  • PDF

절연지의 기계적 및 전기적 물성에 대한 연구 (Study on the electrical and mechanical properties of insulating paper)

  • 엄승욱;김귀열
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권4호
    • /
    • pp.413-417
    • /
    • 1995
  • In order to elucidate the electrical and mechanical properties of insulating paper, it is desirable to study the performances of tensile strength, dielectric constant, dielectric strength. In this work, we constructed the characteristics depending on change of fabrication condition, and these specimens were manufactured by hot press method. As a result, tensile strength was about 75MPa and breakdown was above 5 kV/mm at the minimum value.

  • PDF

Mock-up 부재에 적용한 단열 갱폼의 콘크리트 강도 특성 (Concrete Strength Characteristic of the Insulating Gang Form for Mock-Up Members)

  • 김지훈;남경용;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.67-68
    • /
    • 2013
  • In this paper, the compressive strength of an insulating gang form member, which was developed to improve the cold weather concreting quality, and a general gang form member was measured by age to examine the compressive strength characteristics of the two members compared with the standard curing test piece.

  • PDF