• Title/Summary/Keyword: Instruments

Search Result 4,932, Processing Time 0.031 seconds

Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review

  • Silva, Emmanuel Joao Nogueira Leal;Zanon, Mayara;Hecksher, Fernanda;Belladonna, Felipe Goncalves;de Vasconcelos, Rafaela Andrade;da Silva Fidalgo, Tatiana Kelly
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.25.1-25.12
    • /
    • 2020
  • Objectives: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. Materials and Methods: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. Results: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. Conclusions: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments.

A Study of Analysis about Virtual Musical Instruments' Timbre - Focused on Violin, Erhu, Haegeum - (가상악기의 음색 분석 연구 - 바이올린, 얼후, 해금을 중심으로 -)

  • Sung, Ki-Young;Lee, You-Jung
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.7
    • /
    • pp.219-227
    • /
    • 2019
  • In this paper, we proactively looked at the structure and characteristics of each instrument in order to compare and analyze the sound colors of the western violin, chinese erhu and korean haegeum, which are representative bow string instruments. Also, many performers have simply been unable to fully explain how the violin is rich in pitch and the haegeum has a unique tone. Also, many performers thinks that violin sounds rich just because it has many overtones and have been unable to fully explain how haegeum makes unique tone. While previous research data show that most instruments are studied and published by analyzing their own frequencies or related cases of acoustic studies, this study provides a visual look how the harmonics composition, which determines musical instruments' timbres, consists of and suggests data specifically by analyzing each sound pressure of integer multiple overtones so that the structure of instruments' unique timbre can be understood. Based on this, we hope that it will be of considerable help to the development of virtual musical instruments of korean traditional instruments, which are relatively small compared to western virtual instruments, by reproducing instrument sounds through the synthesizers in the future.

Root surface roughness following mechanical instrumentation, in vitro 3 dimensional planimetric study (기구조작후 치근표면의 조도에 관한 연구; 3차원 측정기틀 이용한 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.823-828
    • /
    • 1998
  • A primary goal of periodontal therapy is the creation of root surfaces that are free of plaque and calculus. It is not yet to be determined whether it is desirable to have a smooth root surface after treatment. It is also not clear what degree of roughness result from different instruments. In the present study various instruments for root surface debridement were evaluated. 20 extracted teeth were utilized, and the teeth were treated with one of the following instrument: Gracey curette, Perio Clean, and piezo ultrasonic device(Setlec, P Max) with general scaler tip, curette-like tip, and diamond tip. 3 dimensional planimetric device(Accura) was used to evaluate the average surface roughness. It was demonstrated hand and power-driven instruments did not have a significant difference in roughness of the root surface following instrumentation. And ultrasonic scaler tip tended to make a most smooth surface than other instruments. The possible reasons of the result were discussed.

  • PDF

TELEMETRY TIMING ANALYSIS FOR IMAGE RECONSTRUCTION OF KOMPSAT SPACECRAFT

  • Lee, Jin-Ho;Chang, Young-Keun
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.117-122
    • /
    • 2000
  • The KOMPSAT(Korea Multi-Purpose SATellite) has two optical imaging instruments called EOC(Electro-Optical Camera) and OSMI (Ocean Scanning Multispectral Imager). The image data of these instruments are transmitted to ground station and restored correctly after post-processing with the telemetry data transfeered from KOMPSAT spacecraft. The major timing information of the KOMPSAT is OBT (On-Board Time) which is formatted by the on-board computer of the spacecraft, based on 1Hz sync. pulse coming from the GPS receiver involved. The OBT is transmitted to ground station with the house-keeping telemetry data of the spacecraft while it is distributed to the instruments via 1553B data bus for synchronization during imaging and formatting. The timing information contained in the spacecraft telemetry data would have direct relation to the image data of the instruments, which should be well explained to get a more accurate image. This paper addresses the timing analysis of the KOMPSAT spacecraft and instruments, including the gyro data timing analysis for the correct restoration of the EOC and OSMI image data at ground station.

  • PDF

New dual cascade loop controller with color LCD bar graphs, equipped with a memory card

  • Kanda, Masae;Uyeno, Mitsugu;Matsuo, Akira;Souda, Yasushi;Terauchi, Yukio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1327-1331
    • /
    • 1990
  • A new dual loop controller using color LCD bar graphs with LED back lights has been developed. An optional memory card is used to load or save the controller configuration, which may be a preprogrammed standard package or a user-programmed configuration, in addition to the built-in functions ready for user selection. The bar-graph display is selectable for single-loop or dual-loop use. A high grade of self-tuning functions using a modeling technique is built-in as standard. The controller can accommodate optional plug-in modules for thermocouples, communication, etc. All the options are fully field upgradable.

  • PDF

A Development of the Management Standard for Effective Control of Measuring Instruments (계측기기의 효율적 운영을 위한 관리표준 개발)

  • Lee, Sung-Woong;Kim, Soo-Dong;Kim, Jung-Sik
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.2
    • /
    • pp.201-217
    • /
    • 1999
  • Industrial Measuring Instrument is a general name of equipments or tools for measuring and weighing. Inaccurate measuring instruments produce inferior goods in spite of excellent experts, good materials and wonderful equipments. Three characteristics are important for measuring instruments: choosing the proper instruments for measuring, using them properly and managing them to keep accuracy and precision. The purpose of this thesis is to develope the management standard for effective control of measuring instruments by analysing the problems and the management conditions of 100 PPM certified companies out of the domestic small and medium manufacturing industry, which steadily carry out quality control.

  • PDF

Experimental Evaluation of Handwriting Performance for the Ergonomic Design of Writing Instruments (필기기구의 인간공학적 설계를 위한 필기성능평가)

  • 권규식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.45
    • /
    • pp.357-364
    • /
    • 1998
  • This study deals with the performance evaluation of writing for designing handwriting instruments ergonomically. Experimental tests were executed on ballpoint pen., felt-tip pen, pencil, sharp-pencil, and fountain pen for ease of use and reduction of the muscles fatigue. The writing time and the degree of comfort of writing by subjects were measured on the diameters of five writing instruments. The results indicated that the ballpoint pen was rated significantly superior to the others in writing speed attribute and the instrument with the least fatigue was the fountain pen. There was a significant interaction effect between the types of instruments and their size in diameters. The diameter of instruments for considering time and comfort together was verified that the size of 9.5mm was efficient for ballpoint pen, the size of 8.1mm for felt-tip pen, the size of 7.5mm for pencil, the size of 8.2mm for sharp-pencil, and the size of 9.1mm for fountain pen.

  • PDF

On-trend utilization of rheological instruments in food industry (식품산업에서 물성분석장치의 활용 동향)

  • Oh, Im Kyung;Lee, Suyong
    • Food Science and Industry
    • /
    • v.51 no.1
    • /
    • pp.2-7
    • /
    • 2018
  • Increasing attention has been paid to rheological approaches in the food industry due to great awareness of the quality control of foods by objective analysis. Therefore, a lot of food manufacturers started to make a great of effort to instrumentally investigate the rheological properties of foods. However, the appropriate utilization of rheological instruments in the field of food science has been met with numerous technical challenges because of the lack of fundamental knowledge and knowhow. In this article, a variety of rheological instruments conventionally used in the food industry are reviewed. In addition, new rheological instruments that have been rapidly growing in popularity are introduced for potential applications. This article may provide an opportunity for the food industry to move toward the active utilization of rheological instruments.

Constrained High Accuracy Stereo Reconstruction Method for Surgical Instruments Positioning

  • Wang, Chenhao;Shen, Yi;Zhang, Wenbin;Liu, Yuncai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.10
    • /
    • pp.2679-2691
    • /
    • 2012
  • In this paper, a high accuracy stereo reconstruction method for surgery instruments positioning is proposed. Usually, the problem of surgical instruments reconstruction is considered as a basic task in computer vision to estimate the 3-D position of each marker on a surgery instrument from three pairs of image points. However, the existing methods considered the 3-D reconstruction of the points separately thus ignore the structure information. Meanwhile, the errors from light variation, imaging noise and quantization still affect the reconstruction accuracy. This paper proposes a method which takes the structure information of surgical instruments as constraints, and reconstructs the whole markers on one surgical instrument together. Firstly, we calibrate the instruments before navigation to get the structure parameters. The structure parameters consist of markers' number, distances between each markers and a linearity sign of each instrument. Then, the structure constraints are added to stereo reconstruction. Finally, weighted filter is used to reduce the jitter. Experiments conducted on surgery navigation system showed that our method not only improve accuracy effectively but also reduce the jitter of surgical instrument greatly.

Analysis of Frequency Characteristics of Writing Instruments Due to Friction (필기구 마찰의 주파수 특성 분석)

  • Shin, JaeUn;Park, JinHwak;Lee, YoungZe
    • Tribology and Lubricants
    • /
    • v.33 no.4
    • /
    • pp.148-152
    • /
    • 2017
  • The feel of writing is important to customers when they buy smart devices with stylus such as smartphones and tablet computers. With an aim to reproduce the tactile sensibility of writing instruments when people write on the glass display using a stylus, this study focuses on the frequency characteristics of writing instruments that can describe the vibrations of writing instruments sliding over counter surfaces. In addition, this study includes the effect of various factors influencing the friction of writing instruments such as lubricant, nib material, and contact type. We perform sliding experiments with six types of writing instruments and a sheet of paper to understand the relation between the friction conditions of the nib and the frequency characteristics. As this research focuses on the tactile perception of human skin when people use a writing instrument, the analysis of frequency characteristics is performed in the perceptible frequency range of mechanoreceptors in the human skin. As a result, three types of frequency characteristics are identified. Low frequency peaks are observed for a metal nib with ink; high frequency peaks are observed for a nib without ink; and, middle frequency peaks with a wide range of distribution occurs for fabric nibs with ink. Therefore, to implement the proper feel of writing, at least three types of vibrations have to be made.