• Title/Summary/Keyword: Instrumentation device

Search Result 167, Processing Time 0.031 seconds

Development of Cylindrical-object Grasping Force Measuring System with Haptic Technology for Stroke's Fingers (햅틱기술을 이용한 뇌졸중환자의 원통물체잡기 힘측정장치 개발)

  • Kim, Hyeon Min;Kim, Gab Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.300-307
    • /
    • 2013
  • This paper describes the development of a cylindrical-object grasping force measuring system applied haptic technology to measure the grasping force of strokes patients' fingers and other patients' paralyzed fingers. Because the cylindrical-object and the force measuring device of the developed cylindrical-object grasping force measuring system are connected with the electrical wires, patients and their families have difficulty not only measuring the patients' grasping force using the system but also knowing their rehabilitation extent when using it. In this paper, the cylindrical-object grasping force measuring system applied haptic technology was developed, and the cylindrical-object grasping force measuring device sends data to the rehabilitation evaluating system applied haptic technology by wireless communication. The grasping force measurement characteristic test using the system was carried out, and it was confirmed that the rehabilitation extent of the patients' paralyzed fingers and normal people fingers can be evaluated.

Modeling and Simulation of 4-Axis Dedicated Robot for CNC Lathe (CNC 선반용 4축 전용로봇의 모델링 및 시뮬레이션)

  • Kim, Han-Sol;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.49-56
    • /
    • 2021
  • This paper describes the modeling and simulation of a four-axis dedicated robot that can attach and detach a workpiece on a computer numerical control (CNC) lathe. The robot was modeled as a Scarab robot for compatibility with CNC lathes. The advantages of such a robot are that an actuator with a small capacity can be used for the robot and the degrees of freedom of the robot can be reduced to four. For the simulation of the four-axis dedicated robot, a regular kinematic equation and an inverse kinematic equation were derived. Simulations were performed with these equations from the position of the loading device to the chuck position of the lathe before machining and from the chuck of the lathe to the position of the loading device after machining. The simulation results showed that the four-axis dedicated robot could be operated accurately, and they provided the joint angle of each motor (θ1, θ2, and θ3).

A Study on the Affected of DC-Link Voltage Balance Control of the Vienna Rectifier Linked With the Input Series Output Parallel LLC Converter (직렬 입력 병렬 출력 연결된 LLC 컨버터를 갖는 비엔나 정류기의 DC 링크 전압 평형 제어에 관한 연구)

  • Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.205-213
    • /
    • 2021
  • Due to the advantage of reducing the voltage applied to the switch semiconductor, the input series and output parallel combination is widely used in systems with high input voltage and large output current. On the other hand, the LLC converter is widely used as a high-efficiency power converter, and when connected by ISOP combination, there is a possibility that input voltage imbalance may occur due to a mismatch of passive devices. To avoid damaging the switching device, this study analyzed the DC-link voltage imbalance of a high-capacity supply using an ISOP LLC converter. In addition, the case where DC-link unbalance control was applied and the case not applied was analyzed respectively. Based on this analysis, an initial start-up algorithm was proposed to prevent input power semiconductor device damage due to DC-link over-voltage. The effectiveness of the proposed algorithm has been verified through simulations and experiments.

A Study on HILS Test Modeling and Simulation for Telegraph Controller Verification (Telegraph 제어기 검증을 위한 HILS 테스트 모델링 및 시뮬레이션 연구)

  • Kim, Sung-Dong;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1612-1618
    • /
    • 2021
  • The telegraph controller is a device used to control the speed of a ship, and it is a device that has a very direct effect on the safety of the crew. Accordingly, ship owners demand very high reliability of the telegraph controller, and the classification trend is to introduce HILS (hardware in loop system) test as a method to verify reliability. Therefore, in this paper, an electric propulsion ship was modeled to perform the HILS test of the Telegraph controller. For modeling, the specifications of the electric propulsion tug boat were defined, and the battery parts, propulsion motor parts, and ship model parts were modeled. In addition, various operation scenarios were defined and the Telegraph controller was modeled accordingly. Finally, the results of the integrated model were confirmed through simulation.

Computer-Interfacing Development for Propeller-Anemometer

  • Saad, Nor Hayati;Janin, Zuriati;Piah, Ruhaidawati Mohd Ali
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.515-519
    • /
    • 2004
  • A Propeller-Anemometer is an instrument used specifically, to measure the wind speed. The accurate measurement of the wind speed is vitally important such required by any weather stations. In this research, the measurand of the instrumentation was the rotational speed of the propeller and the instrumentation result or output data was wind velocity. The speed measured was recorded digitally in the computer by using specific software. A specific sensor used to measure a variable by converting information of the variable (rotational speed of the propeller) into a dependent signal such as electrical signal in form of voltage. The development of Propeller-Anemometer involved few sets of instrumentation process and equipment. It included three major parts, mechanical, electronics and computer. The main instrumentation processes were physical and signal interfacing, signal conditioning, logic interfacing, data transmission to computer and processing the data. Generally, this paper presents the overall concept and design of Propeller-Anemometer Instrumentation. However, an emphasis was mainly in designing and building the interfacing system, hardware and software. Basically, for the first phase of the development, this project designed and built the RS232 terminal using Peripheral Interface Controller (PIC), PIC16F873. The hardware can be interfaced to computer or other compatible devices. This routine converted input voltage from the circuit to speed (velocity) and transmitted them afterwards to the target device by using the RS232 transmission protocol. This implementation implied a computer display as visual interface. For the purpose of this paper, RS232 data transmission was carried out using a Microsoft Visual Basic software routine.

  • PDF

Recent Developments in Nuclear Medicine Instrumentation (최근 핵의학 영상 기기 발전 동향)

  • Kim, Joon-Young;Choi, Yong;Kim, Jong-Ho;Im, Ki-Chun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Sang-Eun;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.471-481
    • /
    • 1998
  • The goals of developments in nuclear medicine instrumentation are to offer a higher-quality image and to aid diagnosis, prognosis assessment or treatment planning and monitoring. It is necessary for physicists and engineers to improve or design new instrumentation and techniques, and to implement, validate, and apply these new approaches in the practice of nuclear medicine. The researches in physical properties of detectors and crystal materials and advances in image analysis technology have improved quantitative and diagnostic accuracy of nuclear medicine images. This review article presents recent developments in nuclear medicine instrumentation, including scatter and attenuation correction, new detector technology, tomographic image reconstruction methods, 511 keV imaging, dual modality imaging device, small gamma camera, PET developments, image display and analysis methods.

  • PDF

Design and Qualification of FPGA-based Controller applying HPD Development Life-Cycle for Nuclear Instrumentation and Control System (HPD 개발수명주기를 적용한 원전 FPGA 기반 제어기의 설계와 검증)

  • Lee, Joon-Ku;Jeong, Kwang-Il;Park, Geun-Ok;Sohn, Kwang-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.6
    • /
    • pp.681-687
    • /
    • 2014
  • Nuclear industries have faced unfavorable circumstances such as an obsolescence of the instrumentation and control system, and therefore nuclear society is striving to resolve this issue fundamentally. IEC and IAEA judge that FPGA technology is a good replacement for Programmable Logic Controller (PLC) of Nuclear Instrumentation and Control System. FPGAs are currently highlighted as an alternative means for obsolete control systems. Because the main function inside an FPGA is initially developed as software, good software quality can impact the reliability of an FPGA-based controller. Therefore, it is necessary to establish a software development aspect strategy that enhances the reliability of an FPGA-based controller. In terms of software development, HDL-Programmed Device (HPD) Development Life Cycle is applied into FPGA-based Controller. The burn-in test and environmental(temperature) test should be performed in order to apply into nuclear instrumentation and control system. Therefore it is ensured that the developed FPGA-based controller are normally operated for 352 hours and 92 hours in test chamber of Korea Institute of Machinery and Materials (KIMM).

A Study of Improvement on the responsiveness of Digital AVR System (Digital 자동전압조정장치(AVR)의 속응성 향상에 관한 연구)

  • Kim, Song-hyun;Lee, Hyung-ki;Choe, Wook-yeon;An, Young-joo;Kim, Hyun-soo;Kim, Gi-Ryang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.246-247
    • /
    • 2015
  • Type of Automatic Voltage Regulator (AVR) can be divided into Analog and Digital Type. Automatic Voltage Regulator (AVR) of the synchronous generators of the brushless type are to be reduced to the voltage fluctuation on the basis of the total load. The PID control method is a general control technique is commonly widely used. In this study, the control target parameter iPID does not reset the parameters of the controller for the variable (Intelligent PID) using the controller synchronous generator Digital automatic voltage to you like all applied to the adjusting device (AVR) the voltage change is small, improved responsiveness was studied in this controller.

  • PDF

A Study on the Auxiliary Power Supply for the Railway Vehicle by Using Wide Band Gap Device (Wide Band Gap 소자를 적용한 철도차량용 보조전원장치에 관한 연구)

  • Choi, Yeon-Woo;Lee, Byoung-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.168-173
    • /
    • 2018
  • In this paper, an auxiliary power supply (APS) for railroad cars is proposed. The APS can reduce the number of devices required to supply power through structural modification and operates at a high switching frequency by application of a SiC device. The voltage stress on the device in the proposed circuit can be reduced to less than half of the input voltage of the system; thus, a device with low breakdown voltage can be designed. By adapting a SiC device instead of an IGBT device, the proposed circuit can reduce switching and conduction losses and operate at a high switching frequency, thereby reducing output voltage and inductor current ripples in the proposed circuit. The theoretical analysis results of the proposed APS are verified with a 40 kW computer-based simulation and a 2 kW experiment.

Characteristics of Vertical Acceleration at Center of Mass of the Body in Normal Gait (정상보행시 체중심의 수직 가속도 특성)

  • Yi, Jin-Bock;Kang, Sung-Jae;Kim, Young-Ho
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.39-46
    • /
    • 2002
  • In this study, vertical acceleration of center of mass was observed along normal gait phases in 9 healthy male volunteers (aged $25.7{\pm}2.18$). The developed wireless accelerometric device was attached on the intervertebral space between L3 and L4 using a semi-elastic waist belt. A three-dimensional motion analysis system, synchronized with the accelerometry, was used for detecting gait phases. There was no significant correlation between the body weight and the acceleration. The first peak curve covered loading response phase. The second downward peak point was matched accurately with the opposite toe-off. In mid-stance and terminal stance, the acceleration curve highly resembled the vertical ground reaction force curve. There was no significant difference in timing between the final upward peak point and the initial contact. Therefore, the developed accelerometry system would be helpful in determining determine temporal gait pattems in patients with gait disorders.

  • PDF