• Title/Summary/Keyword: Instrumentation device

Search Result 166, Processing Time 0.026 seconds

Height Measurement of Cellphone Curved Glass using Camera (카메라를 이용한 휴대폰 곡면유리의 높이측정)

  • Kim, Han-Sol;Lee, Kyung-Jun;Jung, Dong-Yean;Lee, Yeon-Hyeong;Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.1002-1010
    • /
    • 2016
  • This paper describes the design of a cellphone curved glass measuring device using by camera. The measuring device was composed of two camera, two backlight system, a body and so on, and the program was made for a camera calibration and noise removal, and also the program was made for height measurement of a cellphone curved glass using by subpixel algorism. And then a new technique for measuring the height of the cell phone curved glass was proposed. The characteristics test of height measurement of gage blocks and cell phone curved glasses was carried out, the error of the height measurement of gage block is less than ${\pm}0.005$ and the error of the height measurement of the cell phone curved glasses is less than ${\pm}0.005$. Thus it thought that the designed cellphone curved glass measuring device and the new technique for measuring the height was used to measure the height of the cellphone curved glass.

Fabrication and Characteristics of Pyroelectric Infrared Sensor Using $PbTiO_3$/P(VDF/TrFE) Nanocomposites Thin Film (ICCAS 2004)

  • Kwon, Sung-Yeol;Bae, Jong-Il;Jo, Bong-Kwan;Kim, Do;Ahn, Doo-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2041-2044
    • /
    • 2004
  • A pyroelectric sensor using $PbTiO_3$/P(VDF/TrFE) nanocomposites thin film for sensing materials has been fabricated and evaluated with other commercial pyroelectric sensors that use ceramic materials for sensing. The device was mounted in a TO-5 housing to detect infrared light of 5.5 ~ 14 ${\mu}m$ wavelength. The NEP (noise equivalent power) and specific detectivity D of the device were 1.30 ${\times}$ $10^{-8}$W and 1.53 ${\times}$ $10^7$cm /W respectively under emission energy of 13 ${\mu}$W/c$m^2$ respectively. This result shows a better characteristic than the other commercial pyroelectric infrared sensors.

  • PDF

Development of Solid State Relay(SSR) Life Prediction Device for Glass Forming Machine (유리 성형기의 무접점릴레이(SSR) 수명 예측장치 개발)

  • Yang, Sung-Kyu;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.46-53
    • /
    • 2022
  • This paper presents the design and manufacture of a Solid State Relay (SSR) life prediction device that can predict the lifetime of an SSR, which is a key component of a glass forming machine. The lifetime of an SSR is over when the current supplied to the relay is overcurrent (20 A or higher), and the operating time is 100,000 h or longer. Therefore, the life prediction device for the SSR was designed using DSP to accurately read the current and temperature values from the current and temperature sensors, respectively. The characteristic test of the manufactured non-contact relay life prediction device confirmed that the current and temperature were safely measured. Thus, the SSR lifetime prediction device developed in this study can be used to predict the lifetime of an SSR attached to a glass forming machine.

Development of LVAD Control System using Micro Controller (마이크로 컨트롤러를 이용한 전기유압식 좌심실보조기 제어시스템의 개발)

  • Lee, S.W.;Chung, C.I.;Choi, J.W.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.127-129
    • /
    • 1992
  • In this paper, we describe about control system for eletro-hydraulic LVAD(Left Ventricular Assist Device) and control algorithm for two operation mode. One is asynchronous operation mode and the other is synchronous operation mode synchronized with natural heart's R pulse. We also present implementation method of software PI algorithm for velocity control of motor used in LVAD system and its response.

  • PDF

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro (큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

Root surface roughness following mechanical instrumentation, in vitro 3 dimensional planimetric study (기구조작후 치근표면의 조도에 관한 연구; 3차원 측정기틀 이용한 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.823-828
    • /
    • 1998
  • A primary goal of periodontal therapy is the creation of root surfaces that are free of plaque and calculus. It is not yet to be determined whether it is desirable to have a smooth root surface after treatment. It is also not clear what degree of roughness result from different instruments. In the present study various instruments for root surface debridement were evaluated. 20 extracted teeth were utilized, and the teeth were treated with one of the following instrument: Gracey curette, Perio Clean, and piezo ultrasonic device(Setlec, P Max) with general scaler tip, curette-like tip, and diamond tip. 3 dimensional planimetric device(Accura) was used to evaluate the average surface roughness. It was demonstrated hand and power-driven instruments did not have a significant difference in roughness of the root surface following instrumentation. And ultrasonic scaler tip tended to make a most smooth surface than other instruments. The possible reasons of the result were discussed.

  • PDF

Development of an Automatic Ophthalmological Outflow Facility Measuring Device (자동 안압 측정장치의 개발)

  • Kim, H.S.;Choi, Gi-S.;Lim, Y.A.;Ki, C.W.;Kim, W.K.;Hong, T.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.178-181
    • /
    • 1996
  • The Outflow facility of eye ball provides crucial informations in the diagnose of ophthalmological glaucoma. Tn this study an ophthalmic outflow facility measuring device is developed and experimentally tested. This system employs pressure sensors and linear positioning device to regulate solution reservoir height, the pressure of eye ball. The experimental result show that the system works well even in harsh environment so that it can be implemented in ophthalmic practice as well as in biomedical research.

  • PDF

Characterization of thin film transistors using hydrogenated ZnO films and effects of thermal annealing (수소화된 산화아연을 이용한 박막 트랜지스터의 제작 및 열처리 효과)

  • Lee, Sang-Hyuk;Kim, Won;Uhm, Hyun-Seok;Park, Jin-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1412-1413
    • /
    • 2011
  • Effects of thermal annealing on electrical characteristics of thin film transistors (TFTs) using hydrogenated zinc oxide (ZnO:H) films as active channel were extensively investigated. The ZnO:H films were deposited at room temperature by RF sputtering. The device parameters of the ZnO:H-based TFTs, such as threshold voltage ($V_{th}$), subthreshold swing (S.S.), and on-off current ratio ($I_{on}/I_{off}$), were characterized in terms of the annealing temperature as well as the gas flow ratio of $H_2$/Ar.

  • PDF

A Wireless Controllable Group Lighting System for Electrodeless Fluorescent Lamps

  • Ma, Xian-Chao;Xu, Hai;Kim, Hoon;Kim, Hee-Jun;Cho, Kyu-Min
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.166-168
    • /
    • 2007
  • A dimmable ballast system for the electrodeless fluorescent lamp is proposed. The proposed scheme is composed of the electronic ballast and the wireless communication part. They both are realized with one EPLD (Erasable Programmable Logic Device). The dimming levels of each lamps can be controlled by a management system through wireless communication technology. 10 ballasts are used for the group lighting system and the experiment results show the system works well.

  • PDF

A Study on High Impedance Fault Detection using Wavelet Transform and Neural-Network (웨이브릿 변환과 신경망 학습을 이용한 고저항 지락사고 검출에 관한 연구)

  • Hong, Dae-Seung;Ryu, Chang-Wan;Ko, Jae-Ho;Yim, Wha-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.856-858
    • /
    • 1999
  • The analysis of distribution line faults is essential to the proper protection of power system. A high impedance fault(HIF) dose not make enough current to cause conventional protective device. It is well known that undesirable operating conditions and certain types of faults on electric distribution feeders cannot be detected by using conventional Protection system. This paper describes an algorithm using neural network for pattern recognition and detection of high impedance faults. Wavelet transform analysis gives the time-scale information. Time-scale representation of high impedance faults can detect easily and localize correctly the fault waveform.

  • PDF