• Title/Summary/Keyword: Instrumental method

Search Result 387, Processing Time 0.028 seconds

Design of Portable E-Nose System using Neural Network Algorithm (신경회로망을 이용한 휴대용 E-Nose 시스템 개발)

  • Kim, Jeong-Do;Kim, Dong-Jin;Ham, Yu-Kyung;Hong, Cheol-Ho;Byun, Hyung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.39-42
    • /
    • 2004
  • We have designed a portable electronic nose(e-nose) system using an array of commercial gas sensors for recognition and analyzing the various odours. In this paper, we have implemented a portable e-nose system using an array gas sensors and personal digital assistants(PDA) for recognizing and analyzing volatile organic compounds(VOCs) in the field. Field screening for pollutants has been a target of instrumental development for number of year. A portable e-nose system can be substantial benefit to rapidly localize the spacial extent of a pollution or to find pollutants source. And, by using PDA, E-nose have a better function such as the easy user-interface and data transfer by internet from on- site to remote computer. We adapted the Levenberg-Marquardt algorithm based on the back-propagation and proposed the method that could be predicted concentration levels of VOCs gases after classification by separating neural network into two parts.

  • PDF

Fuzzy Logic Controller Design via Genetic Algorithm

  • Kwon, Oh-Kook;Wook Chang;Joo, Young-Hoon;Park, Jin-Bae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.612-618
    • /
    • 1998
  • The success of a fuzzy logic control system solving any given problem critically depends on the architecture of th network. Various attempts have been made in optimizing its structure its structure using genetic algorithm automated designs. In a regular genetic algorithm , a difficulty exists which lies in the encoding of the problem by highly fit gene combinations of a fixed-length. This paper presents a new approach to structurally optimized designs of a fuzzy model. We use a messy genetic algorithm, whose main characteristics is the variable length of chromosomes. A messy genetic algorithms used to obtain structurally optimized fuzzy models. Structural optimization is regarded important before neural network based learning is switched into. We have applied the method to the exampled of a cart-pole balancing.

  • PDF

Health Status of Elderly Living in a City (노인의 건강상태)

  • So, Hee-Young;Kim, Hyun-Li;Liu, Ming Ren
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.7 no.2
    • /
    • pp.169-178
    • /
    • 2004
  • Purpose: This study examined the health status of elderly. Method: This is a survey using cross-sectional design. The subject were 122 elders who were 65 and over in Daejeon. Instrumental activity of daily living, nutrition and Body mass index for physical health status, social engagement for social health status, and depression and loneliness for emotional health status were measured. Results: Independent level was medium, and nutrition and BMI were normal level. Social engagement score was 2.38 which means low. Mean depression level was 7.71 and mean loneliness level was 56.77, which means high. The risk factors for vulnerable health status were no spouse, lower pocket money, living at institution, poor subjective health status. Conclusion: This finding indicates that the elderly subjects were in normal physical health status, but social and emotional health status were poor.

  • PDF

Photoelectric Observations of the Close Eclipsing Binary System CW Cephei

  • Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.1 no.1
    • /
    • pp.41-53
    • /
    • 1984
  • Photoelectric observations of the close eclipsing binary system CW Cep, which is well known of its apsidal motion, were made on 20 nights during August and November in 1983 using two 61cm reflectors at the Sobaeksan Observing Station of Korean National Astronomical Observatory and I1san Observing Station of Yonsei University Observatory. Standardized new light curves in UBV system are presented with a total of 1,422 individual observations. For the corrections of regional and instrumental differences, same standard stars were observed at the two observatories. Four new times of minimum light were determined with the method of Kwee and van Woerden(1956). With all of the collected times of minima, apsidal motion of this system was checked, but the O-C values calculated by the light elements of Nha(1975) and Soderhjelm (1976) did not coincide well with new times of minima. New light elements which satisfy most times of minima better, and are deduced the apsidal period derived by the new light elements turns out to be 43 years, somewhat longer than those of values previously known.

  • PDF

Characterization of Nanocomposite Ti-Si-N Films Prepared by a Hybrid Deposition System of A If and Sputtering Techniques (하이브리드 증착 시스템을 이용한 나노복합체 Ti-Si-N 박막의 특성 연구)

  • 윤순영;최성룡;이미혜;김광호
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.2
    • /
    • pp.122-127
    • /
    • 2003
  • Ti - Si - N hard films were deposited on SKD11 steel substrates by a hybrid deposition system, where TiN was deposited by AIP method while Si was incorporated by sputtering one. The microstructure of Ti-Si-N films was revealed to be a composite of TiN crystallites and amorphous Si3N4 by instrumental analyses. The highest hardness value of about 45 Gpa was obtained at the Si content of around 7.7 at.%. With increase of Si content, the size of TiN crystallites was reduced and their distribution was changed from aligned to randomly orientated states. Surface roughness of Ti-Si-N film also decreased with increase of Si content.

Microstructural and Mechanical Characterization of Nanocomposite Ti-Al-Si-N Films Prepared by a Hybrid Deposition System (하이브리드 증착 시스템에 의해 합성된 나노복합체 Ti-Al-Si-N 박막의 미세구조와 기계적 특성)

  • 박인욱;최성룡;김광호
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.2
    • /
    • pp.109-115
    • /
    • 2003
  • Quaternary Ti-Al-Si-N films were deposited on WC-Co substrates by a hybrid deposition system of arc ion plating (AIP) method for Ti-Al source and DC magnetron sputtering technique for Si incorporation. The synthesized Ti-Al-Si-N films were revealed to be composites of solid-solution (Ti, Al, Si)N crystallites and amorphous Si3N4 by instrumental analyses. The Si addition in Ti-Al-N films affected the refinement and uniform distribution of crystallites by percolation phenomenon of amorphous silicon nitride, similarly to Si effect in TiN film. As the Si content increased up to about 9 at.%, the hardness of Ti-Al-N film steeply increased from 30 GPa to about 50 GPa. The highest microhardness value (~50 GPa) was obtained from the Ti-Al-Si-N film haying the Si content of 9 at.%, the microstructure of which was characterized by a nanocomposite of nc-(Ti,Al,Si) N/a$-Si_3$$N_4$.

Surgical treatment of esophageal perforation (식도천공의 외과적 치처 및 임상고찰)

  • 조성준
    • Journal of Chest Surgery
    • /
    • v.27 no.7
    • /
    • pp.598-602
    • /
    • 1994
  • We have experinced 20 cases of esophageal perforation from April, 1987 to August, 1993 at ourdivision of Thoracic and Cardiovascular Surgery, Korea University, Gu Ro Hospital. Here we investgates the causes of disease, symptoms and sign, locations, time lag from onset, treatment of perforation and the results.The ratio between male and female patients was 12: 8, and age ranged from 4 years to 70 years old.The cause of esophageal perforation were instrumental trauma 7 cases, stab wound 4 cases, foreign body 4 cases, spontaneous perforations 3 cases, and others 1 cases. The middle and lower portions of esophagus was frequently involved portion in our cases [11 cases of 20].The common complications after perforation were mediastinitis [6 cases] and empyema [2 cases].The method of treatment were as follows, primary repair of perforation, simple drainge techniques including simple cervical drainage and closed thoracostomy, diversion and two-staged operations during several months. There was no mortality in our cases.

  • PDF

Stability evaluation of foundation settlement of power transmission tower (송전철탑의 기초침하에 대한 안정성 평가)

  • Lee, Dae-Soo;Cho, Hwa-Kyung;Kim, Dae-Hong;Ham, Bang-Uk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.687-696
    • /
    • 2005
  • Safety diagnosis was conducted to evaluate the long-term stability evaluation of power transmission tower of which deformation of the upper structural elements occurred. To assess the cause of the structural deformation, field investigation including BIPS, down-hole test, concrete pile coring and finite element analysis were carried out. From these studies, the major cause of deformation was found due to the heavily fractured layer and weathered soil topography at the pile tip area. The cement-milk grouting method was proposed to reinforce these weak zone around the pile tip area. Also, the increase of cross-section and stiffness for steel members of upper tower structures was suggested. Instrumental monitoring was proposed as well to verify reinforcing effect.

  • PDF

On the Sampling and Transport of Radioactive Aerosols from Waste Thermal Process

  • Yang, Hee-Chul;Kim, Joon-Hyung;Yong Kang
    • Nuclear Engineering and Technology
    • /
    • v.29 no.4
    • /
    • pp.269-279
    • /
    • 1997
  • The errors associated with incorrect sampling and transport of radioactive aerosol from radwaste thermal process off-gas are analyzed and the conditions of representative sampling and correct transport of radioactive aerosol for off-gas system evaluation are discussed. An estimation method of sampling errors for individual radionuclides is proposed and applied to simulated vitrification melter aerosols. Prediction methods for particle deposition in sample transport tube under laminar as well as turbulent flow conditions are also described by example calculations with simulated incinerator off-gas From the results of example calculations and plots, instrumental and operational conditions of radioactive aerosol sampling system with minimized errors and correction methods for nonideal sampling and transport are recommended.

  • PDF

Error Correction of Laser Interferometer Using Capacitive Sensor (정전용량센서를 이용한 레이저 간섭계 오차보정)

  • Kim, Jae-Cheon;Seo, Suk-Hyun;Jeon, Jae-Wook;Park, Ki-Heon;You, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.342-344
    • /
    • 2006
  • During last years, large investments have been directed to development and research of nano-technological products like semiconductor, display panel, optic-fiber communication components, life technology, and ultra-precision components. All quantitative measurements at nanometre scale should guarantees accurate results and high quality. Laser interferometer is one of most famous nanometre scale devices to be able to measure metre-scale distance with nanometre scale resolution, but it is easily affected by various error causes like geometrical, instrumental and environmental factor. On the other side, capacitive sensor is robust to above error factors, but it is able to measure relatively shorter distance, under $100{\mu}m$, than laser interferometer. New error correction method for laser interferometry using capacitive sensor will be introduced in this paper.

  • PDF