• 제목/요약/키워드: Instrument transformer

검색결과 39건 처리시간 0.027초

변압기 용량을 고려한 수용률 산출 시뮬레이터 개발에 관한 연구 (A Study on Simulator for Computing Demand Rate Considering a Transformer Capacity)

  • 김영일
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.179-185
    • /
    • 2007
  • In this paper, the method of computing demand rate with respect to a transformer capacity is proposed and addressed to predict a future demand rate. The simulation data are taken from switchgears of a real medium voltage transformer. Data taken from the electrical instrument at 22.9 kVY power receiving panels are employed to evaluate the correlation between demand rate and power usage of transformer. It is verified a usefulness with respect to an proposed index of demand rate for transformer by using a least square error of regressive modeling, As a result of investigation and simulation on the spot to a few buildings, it is considered that there is necessity to make a partial amendment of demand rate being applicable currently for electrical energy saving in domestic.

소형 변압기 안전성 실태 분석 및 고찰 (The Safety Survey Analysis and Consideration of Small Transformer)

  • 김성삼
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

KTX 주변압기의 진동특성 분석 (Vibration Characteristic Analysis of the Main Transformer for KTX)

  • 김진우;양재철;허민웅;김대식;김호순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.649-655
    • /
    • 2011
  • In this paper, the content to carry out the modal testing and to analyze the data as the target of the main transformer installed on KTX is mentioned. The main transformer for KTX is a structure which is over 10 Ton. For the possibility to occur a stress concentration phenomenon exists, the dynamic durability of the system is experimentally needed to understand. To do this, we obtained the vibration data using an accelerometer, an impact hammer, a measuring instrument and gained the frequency response function of the main transformer based on the acquisition data. In this content, when the theoretical model for structural analysis should be established, we think it will be used for the property verification of analytical model. Also, we expect that the measured and analysed data will offer basic research material to maintain the system and diagnose the condition by monitoring the natural frequency of the main transformer for KTX periodically.

  • PDF

전력기기 예방진단 기술을 위한 저전압 충격시험 (Low Voltage Impulse Test for Power Electric Instrunment Precaution Diagonsis Techniques)

  • 곽희로;김재철;권태원;윤용범;손진근;윤지용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.281-285
    • /
    • 1991
  • In this paper, response characteristics by applying impulse into transformer windings in order to precaution diagonosis of power electric instrument are studied. A sample oilless transformer, an aging transformer and a good transformer are slected for models. The experimented results show that for testing the windings distortion and impedanced change of transformer the LVI method are suitable. Also, variation characteristic of output waveforms at time and frequency domain in order to efficient analysis is discussed. The results response that waveforms at frequency domain is very higher resolution at time domain.

  • PDF

변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial Discharge in Transformers)

  • 곽희노;김재철;황선주;권태원;윤용범
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권4호
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

철심 코어형 전자식 전압 변성기 개발 (Development of the iron-cored electronic voltage transformer)

  • 강용철;박종민;장성일;김연희;최정환;김용균;송인준;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.138-139
    • /
    • 2008
  • An iron-cored voltage transformer(VT) is usually used to obtain the standard low voltage signal for protection and measurement. Generally, the iron-cored transformers have errors due to the hysteresis characteristics of the iron-core. An error compensating algorithm for iron-cored instrument transformer can improve the accuracy of conventional voltage transformers. This paper describes the iron-cored electronic voltage transformer having the error compensating algorithm. The innovative product composes an iron-cored VT and an intelligent electronic device(IED) having the error compensating algorithm. The test results of the iron-cored electronic voltage transformers in Korea Electro-technology Research Institute(KERI) are presented.

  • PDF

펄스레이저 및 광다이오드를 이용한 변압기 절연유의 절연감시법 (Monitoring method of transformer insulationg oil using pulsed-laser and photodiode)

  • 조정수;양동민;안광선;윤성호;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2130-2132
    • /
    • 1999
  • This paper is research for the practicability of instrument which can apply to the transformer on the spot with the criteria of insulation oil with the method of measuring the volume of $H_2O$ in the insulation oil by playing insulation oil with the significant role for precaution diagnosis on breakdown of transformer among power system into Nd:YAG laser.

  • PDF

로고스키 코일과 초음파 센서를 이용한 변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial discharge in Transformers Using Logoski coil and Ultrasonic sensor)

  • 곽희로;김재철;김웅상;한민구;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 1990
  • This paper describes an nstrument for the detection and geometric location of partial discharge(PD) sources in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulse and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used, satisfactory for detecting and locating of PD in the transformer.

  • PDF

250 mA 이하 출력전류를 갖는 전류변성기 특성평가 연구 (A Research on Characteristics Tests for Current Transformers with Maximum mA Secondary Current of 250 mA)

  • 송광재;이일호;송상훈
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2127-2137
    • /
    • 2016
  • In this paper, characteristic tests for current transformers with maximum mA secondary current of 250 mA is performed. The purpose of this paper is not only to test the mA current transformers by following the IEEE Draft Standard for Current Transformers with Maximum mA Secondary Current of 250mA, but also to take into consideration certain applications in the use of the mA CTs for billing purposes.