• Title/Summary/Keyword: Instrument Panel

Search Result 128, Processing Time 0.026 seconds

Intelligent Substation Construction of 154kV Class (154kV 인텔리전트 변전소 구축)

  • Kim J B.;Chung Y. H.;Song W. P.;Choi I. H.;Kim J. H.;Lee D. I.;Koh H. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.524-526
    • /
    • 2004
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(UP) replaces local panel which is drived by mechanical operation. For monitoring condition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.661-662
    • /
    • 2007
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this paper, we mention the synopsis and report the progress state of project.

  • PDF

Translation and Validation of Korean Version of Hall's Professionalism Inventory (간호의 전문직업성 척도 개발을 위한 Hall의 전문직업성 척도 번역 및 동등성 비교)

  • Kim, Yeoun-Soo;Baek, Hee-Chong
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.13 no.4
    • /
    • pp.509-515
    • /
    • 2007
  • Purpose: The purpose of this study was to translate and validate the Korean version of Hall's Professional Inventory(HPI) scale to assess levels of professionalism among Korean registered nurses. Method: The 25 item HPI scale was translated and content review was done by translation panel. After the content review, a bilingual nursing scholar performed the back-translation into English. A semantic equivalence test was conducted with 5 American nursing professors. A pilot study was conducted with a sample of 164 registered nurses in Korea to test the validity and reliability of the translated HPI. Result: The content equivalence for translated version of HPI was validated by a translation panel. The finding of the semantic equivalence test of back-translated version was 72.8%. The Cronbach's alpha for the Korean version of HPI was .820. Conclusions: This study provides information about the issues of translating an instrument such as the HPI. The Korean version of the HPI is a valid and reliable instrument and can have psychometric properties equivalent to those of the original HPI. The translated version could be used for assessing levels of professionalism for other health care professionalism as well as nurses.

  • PDF

Design of forklift status information system using Android device (안드로이드 기기를 활용한 지게차 상태 정보 시스템 설계)

  • Park, Se-il;Jang, Jong-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.233-235
    • /
    • 2017
  • Forklift tend to work in place rather than moving due to work environment conditions, so they express only the engine operation time without expressing the moving distance unlike a general car's instrument panel. Therefore, various consumables constituting the forklift have a replacement cycle according to the operation time of the engine. However, it is very difficult to judge the exact replacement cycle only by the engine operation time because the working environment differs for each forklift. In this paper, we propose a system that provides position information and moving distance information of forklift to driver using GPS and IMU sensor. By using this system, it is expected that the forklift status information, which is difficult to judge by the existing instrument panel, is provided as easier information, and economic benefits for forklift management and maintenance are expected.

  • PDF

Development of an Instrument to Measure Meaning of Life(MOL) for Higher Grade Primary School Children (학령기 후기 아동의 삶의 의미 측정도구 개발)

  • Kang, Kyung-Ah;Song, Mi-Kyung;Sim, Song-Yong;Kim, Sung-Hee;Kim, Shin-Jeong
    • Child Health Nursing Research
    • /
    • v.13 no.3
    • /
    • pp.308-317
    • /
    • 2007
  • Purpose: The purpose of this study was to develop a MOL instrument for school-age children in grades 4 through 6. Method: The research design was a methodological study. A four-phase design involved. 1) Interview data generated from professors, nurses, and elementary school students (n=8). 2) Content validation by expert panel (n=14) 3) Initial items corrected by elementary school students (n=20) 4) Instrument validation by survey (n=574). Finally, 24 items were chosen as a meaning of life scale for late school-age children. Results: The Cronbach's alpha coefficient of 24 items was .893 indicated a high internal consistency of the instrument, 2) Through factor analysis, 5 factors were extracted. These factors were labeled as 'relational experience', 'positive attitude', 'satisfaction/ hope', 'pursuit of goal', and experience of family love. These factors explained 52.311% of the total variance. Conclusion: The MOL scale for late school-age children can be used in nursing programs to improve the meaning of life. Studies on difference in meaning of life for late school-age children are needed for reverification.

  • PDF

Reliability and Validity of an Instrument for Adolescents Meaning in Life Scale(AMIL) (청소년 대상 생의 의미 측정도구의 신뢰도 및 타당도 검증)

  • Kang, Kyung-Ah;Kim, Shin-Jeong;Song, Mi-Kyung;Sim, Song-Yong
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.5
    • /
    • pp.625-634
    • /
    • 2007
  • Purpose: The purpose of this study was to test the reliability and validity of an MIL instrument for adolescents. Method: The research design was a three-phase, methodological study. 1) The original 46 items of the Meaning in Life (MIL) Scale were reviewed and corrected partially by 20 adolescents. 2) The content was validated by an expert panel (n=15) and adolescents (n=5). 3) The instrument was validated by survey (n=468). Finally, 33 items were chosen for the adolescents meaning in life(AMIL) scale. Results: Cronbach's alpha coefficient of the 33 items was .92, confirming the high internal consistency of the instrument. 2) Eight factors were extracted through factor analysis: 'experience of love', 'making efforts for goal', 'awareness of essential being', 'awareness of self limitation', 'feeling of satisfaction', 'relation experience', 'positive thinking', and 'hope'. These factors explained 58.26% of the total variance. Conclusion: AMIL Scale was identified as a tool with a high degree of reliability and validity. The tool can therefore be effectively utilized to assess the degree of meaning of life in caring areas for adolescents. Studies on AMIL of different adolescent subjects are needed for further verification.

The Development of Client Satisfaction Instrument in Home Care Service (가정간호서비스에 대한 대상자 만족도 측정도구 개발)

  • Park, Hyun-Tae;Park, Jung-Ho
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.8 no.2
    • /
    • pp.159-170
    • /
    • 2001
  • Client(patient) satisfaction has been used for a variety of purposes in different settings, yet, those receiving home care services have been the focus of few satisfaction studies. Satisfaction is considered an indicator of quality of care and is also being used to assess the performance of home care providers and home health care delivery at multiple levels. The aim of this study was to develop the tool for evaluating client satisfaction in several aspects with home care service while maintaining or achieving acceptable reliability and validity. Firstly, Client Satisfaction Instrument made preliminary of 43 items composed basic 6 criteria and 7 indicators, based on a review of literature, quality improvement and client satisfaction findings in home care. Secondly, there were consisted in two expert panel groups who were made in professionals of research and practice in home care field. The tool was modified to 6 criteria and 7 indicators, 25 items after reviewing by two expert panel groups. The content validity index of the tool was above 0.8 and the results of internal consistency was more than 0.8 in all items. Finally. The Client Satisfaction Instrument in Home Care Service was made up 6 criteria such as client satisfaction of nurses's instruction of home care educational need. knowledge/technique/attitude of homecare nurses's performance. interpersonal relationship and emotional support of nurse. easiness of homecare accessibility, continuity of homecare service. overall efficacy of homecare use, 7 indicators. and 25 items. The results of evaluating client satisfaction will be able to contribute in quality improvement and service marketing in home care.

  • PDF

A Study on Designing of a Menu Structure for the Instrument Cluster IVIS using Taguchi Method (다구찌 방법을 이용한 Instrument Cluster 상의 IVIS 메뉴 설계에 대한 연구)

  • Hong, Seung-P.;Kim, Seong-M.;Park, Sung-Joon;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • The growth of function in vehicle needs complex display and control system, the In-Vehicle Information System(IVIS). Although current IVISs are widely implemented in commercial vehicles, a new form of IVIS has been recently studied in order to reduce drivers' workloads. The purpose of this study is to suggest an appropriate menu structure of a new type IVIS, to be implemented on the instrument cluster panel, using Taguchi's parameter design. In the research, firstly, functions were selected that are appropriate to control through the instrument cluster among existing functions of current IVISs by quantitative evaluation of ergonomic principles. Then, menu structure alternatives were extracted by investigating priorities to those functions selected. Finally, menu structure alternatives were evaluated through an experiment and suggest the most appropriate one by applying Taguchi's parameter design. Taguchi method was used not only for planning an experiment but also evaluating alternatives. SN ratios were a key value to evaluate the alternatives and to find the most proper one. Through the research, the most appropriate menu structure for the instrument cluster IVIS was finally suggested among the alternatives and it is expected that the results of this research could provide a guideline to the instrument cluster IVIS.

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

The Effect of Private Health Insurance on Health Care Utilization: Evidence from Korea Health Panel (2008~2010) (민간의료보험이 의료 이용에 미치는 영향: 한국의료패널(2008-2010)을 이용한 Two-Stage 분석)

  • You, Chang-Hoon;Kang, Sung-Wook;Choi, Ji-Heon;Oh, Eun-Hwan;Kwon, Young-Dae
    • The Korean Journal of Health Service Management
    • /
    • v.8 no.2
    • /
    • pp.101-113
    • /
    • 2014
  • This paper examined the effects of private health insurance(PHI) on the health care utilization among the Korean. The used data was the three waves of Korea Health Panel (2008, 2009, 2010), and the number of subjects was 13,951 persons. Authors employed two-stage least square panel model where the instrument variables for controlling for endogeneity of PHI were number of insurance planner per 100,000 in resident area and whether subject worked on financial profession. The results showed that healthcare expenditure of outpatients who purchasing PHI was higher than that of outpatients without PHI, and there was no difference in admission between the two groups. This article recommended the Korean government to monitor the effects of PHI on the health care utilization in order to improve the efficiency of health care finance.