• Title/Summary/Keyword: Instrument Development

Search Result 1,464, Processing Time 0.029 seconds

The development of tube voltage meter using the semiconductor (반도체소자를 이용한 관전압계의 개발)

  • Seon, Jong-Ryul;Shin, Dae-Chul
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.71-75
    • /
    • 2002
  • According to this study, we can make the radiation check meter which have not supply because of high cost and import barrier and lengthen its life by means of repairing of radiation bomb and equipment. We can make better medical service. In my study, I used the photodiod, photoelectron, among semiconductor detectors which have a excellent detect capacity and are low cost and small size. I set up this equipment in June 1, 2002, used 640 mA remote operative fluorography equipment, which make the grade as capacity test. I used the standard measuring instrument which took proofs from a agency, now it was using in measuring agency. The comparative measuring instrument used in same condition. I took the standard which was gauged with a connecting measuring instrument. Using a existing unconnected measuring instrument, I compared the accuracy with new unconnected one. As a result, three score are within the standard. For the detailed analysis, I took the average of percentage average error. So standard instrument was -0.02, comparable was -0.22, and new one was -0.17. New one took a closer measured value with standard than comparable one. In more study, I think to take more accurate value. I expect that my study will be a base of measuring instrument, with low cost, supply of this instrument increase, I expect to decrease radiation bomb and maintain, repair and manager better.

  • PDF

Development of Wireless Measurement System of Somatic Informations for Stockbreeding Automatization(I) -Development of Single-Channel Wireless Instrument for Measuring Temperature- (축산자동화를 위한 가축의 생체정보 무선 계측장치의 개발(I) -단일채널 체온 무선 계측장치의 개발-)

  • Lee, S.K.;Min, Y.B.;Kim, T.K.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.4
    • /
    • pp.363-371
    • /
    • 1991
  • It is important to measure the somatic informations for stockbreeding automatization. This study was carried out for the development of wireless measurement system of temperature in living animals. New method to measure somatic temperature was developed using the single-channel wireless instrument. This system was constructed by oscillator, temperature sensor, wireless transmitter and receiver circuit, single processing circuit, and microcomputer. Two types of sensor were used and compared to measure the temperature. The thermistor sensor was more sensitive and accurate than platinum resistance sensor, however both sensors were performed efficiently. The single-channel wireless measurement systems developed could measure the somatic temperature successfully and offered a versatile system.

  • PDF

A Survey of Teaching Effectiveness and the Development of an Evaluation Instrument for Clinical Education (임상실습지도자의 효율성 조사와 임상평가도구 개발)

  • Kwon, Mi-Ji
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.1
    • /
    • pp.177-186
    • /
    • 2002
  • The purpose of this study was to contribute to the development of clinical instruction by students ratings of teaching effectiveness in clinical education. The instrument used in this study was teaching effectiveness of clinical nursing by Yu and modified evaluation method by Kern and Mickelson. The results were are follows 1. Among the 12 categorial components of clinical teaching effectiveness, the highest satisfaction was 'encouraging to think for themselves' and the lowest was 'attitude of teacher and evaluation' 2. To compare teaching effectiveness between sex, 'resource for student' and 'professional competence' showed statistical significance. 3. To compare teaching effectiveness among clinical practice stage, 'encouraging' 'role model', 'professional competence', 'organization of subject mater' and 'attitude of teacher and evaluation' showed statistical significance. 5. Interrater ICCs for evaluation method did not showed statistical significance and interitem ICCs showed statistical significance. This article presents goal of clinical education, development of clinical instructor's educational program and a standardized method to measure clinical performance.

  • PDF

Development of Wireless Instrument for Measuring Cattle's Somatic Information for Stockbreeding Automatization(II) - Development of Single-Channel Wireless Instrument for Measuring Sphygmus - (축산자동화를 위한 가축의 생체정보 무선 계측장치 개발(II) - 단일채널 무선 맥박 계측장치 개발 -)

  • Lee, S.K.;Min, Y.B.;Kim, T.K.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 1992
  • It is important to measure the somatic informations for stockbreeding automatization. This study was carried out for the development of wireless measurement system of sphygmus in living animals. In meauring sphygmus counting with the single-channel telemety system, a LED-photo transistor sensor showed more sensitivity to the change of blood pressure than a piezo-electric sensor based pressure sensor. The LED-photo transistor sensor resulted ${\pm}1.29%$ of measurement error of sphygmus counting. In the process of transmitting and receiving the blood pressure signal for counting sphygmus, noises were mixed with, and the noises made the counting almost impossible. Auto-correlation analysis technique was applied to the signal data to extract the sphygmus information, and the technique was proved to be very effective.

  • PDF

A Study on a Development of Hybrid(Magnesium & Steel) Structure for Application of Cockpit Module (Cockpit Module용 Hybrid Structure개발에 관한 연구)

  • 박병구;이정환;김영삼;한성수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.166-170
    • /
    • 2002
  • A hybrid structure composed of magnesium and steel is Instrument Panel structure used for the basement of cockpit module components. For that reason, A hybrid structure has to be designed for satisfying components assembly design facility and styling. There are various models of If like steel structure assembly, however having been applied normally, but magnesium structure assembly selected far saving weight down. This paper introduces a hybrid structure having advantages between steel and magnesium structure and presents a CAE technical solution based on a development project. furthermore, it provides desired direction of the future development is suggested.

The Child Psychological Well-being Scale : Development and Validity (아동의 심리적 복지척도 개발과 타당화 연구)

  • Choi, Jin Won;Lee, So Hee
    • Korean Journal of Child Studies
    • /
    • v.23 no.4
    • /
    • pp.227-248
    • /
    • 2002
  • The purpose of this study aimed at establishing the validity and reliability regarding the instrument of assessing child psychological well-being. The child psychological well-being rating scale contained 3 dimensions (sense of competency, sense of relation, sense of improvement) 8 variables (sense of control, sense of achievement, sense of confidence, sense of acceptance, sense of intimacy, sense of balance, sense of morale, sense of hope) and 4 rating scale of 80 items. After the scale development, the estimates of reliability for the scale were high. Cornbach ${\alpha}$ was .962 and generalizability was .875. And concurrent validity, criteria related validity, and discriminant validity appeared to be evident sufficiently to the validity of child psychological well-being instrument. The significance of the present study was intended to apply scale validity procedure by using generalizability.

  • PDF

A Study on the Development of EKG Monitor in Operating Room (수술실용 EKG Monitor의 개발에 관한 연구)

  • 김원기;박용재
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.31-34
    • /
    • 1982
  • The development of biomedical instrument that is widely used in hospital played a important role in engineering with advance of electronic engineering. We have initiated the development of EKG monitor which is basically used in biomedical equipment, and then accomplished it especially considered patient safety.

  • PDF