• 제목/요약/키워드: Instrument Accuracy

검색결과 336건 처리시간 0.025초

모터 구동장치를 위한 DSP기반 3상 전력품질분석 시스템 (A DSP based Three Phase Power Quality Analyzer for Motor Drives)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.661-664
    • /
    • 2000
  • This paper presents a digital instrument for the power quality analysis in three phase power system where current waveform is non-sinusoidal. It is based on C31 DSP and on a special high-speed data acquisition system. Voltage and current waveforms are acquired and processed by using a simple average power algorithm, The paper also goes on to discuss the performance of an instrument prototype both in terms of accuracy and speed of measurement.

  • PDF

이중단방향 반송파 거리측정기 비행성능 분석 (Flight Performance of a Dual One-Way Carrier Phase Ranging Instrument)

  • 김정래
    • 한국항공운항학회지
    • /
    • 제17권1호
    • /
    • pp.52-57
    • /
    • 2009
  • One of the error sources for microwave ranging is the instability of the oscillator that drives the microwave signals. Dual one-way ranging (DOWR) minimizes the oscillator effect by combining two one-way carrier phase signals from two transmitter/receiver instrument. The DOWR is first implemented in the GRACE (Gravity Recovery and Climate Experiment) satellites. Direct evaluation of the DOWR is not possible due to its extremely high accuracy. The flight performance of the GRACE DOWR is analyzed by applying several indirect methods. Comparison with the design noise level is discussed.

  • PDF

측정기의 효율적 운영에 관한 실증적 연구

  • 유현종;정수일
    • 건설안전기술
    • /
    • 통권48호
    • /
    • pp.64-74
    • /
    • 2009
  • Measurement is a essential part in all kinds of industry, especially in manufacturing. But until now, measurement hasn't been located to the core of manufacturing in domestic. This improvement guide line for the multilateral problems of measuring instrument investigation of small and medium-sized enterprises. To use measuring treat it must be accustomed with the structure, the performance, the method. must be corrected periodically. The correcting-schedule is established with accuracy, stability, purpose, condition, and frequency.

  • PDF

비접촉식 센서를 이용한 초장축 롤러 측정 장치 개발에 관한 연구 (A Study on the Development of Measuring System for Extra Long Roller Using Non-contact Sensor)

  • 김웅;이춘만;이문재;박성진
    • 한국정밀공학회지
    • /
    • 제27권4호
    • /
    • pp.33-39
    • /
    • 2010
  • Manufacturing accuracy of a precision instrument was essential to stability and efficiency of the product. Accordingly, geometrically accuracy management of precision instrument was very becoming the technique in order to design and manufacturing for machine. In this study, Measuring System is developed for extra long roller using non-contact sensor. Futhermore, It's studied by Geometric Tolerance. Exact roundness is obtained to Least Squares method from the reference circle of measured data. Measuring System is analyzed point of measurement and straightness of extra long roller is evaluated by FEM.

Accuracy-improvement simulation of self-mixing semiconductor laser range finder driven by reshaped modulation current

  • Shinohara, Shigenobu;Nobunaga, Kazuhiko;Yoshida, Hirofumi;Ikeda, Hiroaki;Miyata, Masafumi;Nishide, Ken-ichi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1021-1026
    • /
    • 1990
  • Accuracy improvement of a self-mixing semiconductor laser range finder is predicted by simulation, in which the laser modulation current is reshaped to give an ideal triangular waveform of the optical frequency change. The maximum range measurement error of less than 0.1% in a wide range of O.1m to 1m is expected by the reshaping of the modulation current. Experimental verification of the effect of current reshaping on the linearization of the derivative of the optical frequency change curve is given.

  • PDF

임피던스 방법을 이용한 뇌혈류량 측정기기의 개발( I ) (Development of Rheoencephalograph(I))

  • 김덕원;김정래
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권1호
    • /
    • pp.25-32
    • /
    • 1989
  • In this study, Rheoencephalography( REG ) was designed and constructed. Using the cons- tructed instrument cerebral blood flow(CBF) of left and right brain, CBF change by posture, and reproducibility were studied. Followings are important results. Relative CBF could be measured noninvasively and continuously. Since reproducibility of the constructed REG was found to be quite high (4%), the accuracy of the instrument itself was proved. REG can be easily applied for testing the effect of drugs for the patients with cerebral vessel diseases since it is quite sensitive to the relative changes of CBF. Various cerebral diseases can be diagnosed by analyzing the REG waveforms. The area of restricted cerebral blood vessels can be located by arranging the electrode configuration. Comparative studies with the standard techinques of measuring CBF are needed to verify the accuracy of REG. Further studies on optimal electrode configuration and various artifacts are also necessary.

  • PDF

배터리의 잔여 수명 평가를 위한 고압 임피던스 분광장치의 개발. (Development of the High Voltage EIS Instrument for the Evaluation of the Residual Useful Life of the Batteries)

  • Farooq, Farhan;khan, Asad;Lee, Seung June;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 추계학술대회
    • /
    • pp.216-217
    • /
    • 2019
  • The battery powered electric vehicle (EV) is one of most promising technologies in 21st century. Though the lithium batteries are playing an important role in the EVs, they are only applicable until their capacities reach 80%, the end of its useful first life. Yet, these batteries can live a second life such as Energy Storage Systems (ESS). In order to utilize the Residual Useful Life (RUL) of the batteries the State of Health (SOH) of them needs to be estimated by a nondestructive test such as Electrochemical Impedance Spectroscopy (EIS) technique. Though many kinds of different EIS instruments are commercially available, most of them can only test a battery module less than 10V and the price of the instrument is very high. In this paper a low-cost EIS instrument suitable for measuring the impedance spectrum of the high voltage battery module is proposed and its validity is verified through the experiments. In order to prove the accuracy of the developed EIS instrument its measured impedance spectrum is compared with the results obtained by a commercial instrument. The Chi Square value calculated between two impedance spectrum measured by both developed and commercial instruments are less than 2%, which prove the strong correlation between two results.

  • PDF

A Wide-range Tunable Wavelength-stabilization Technique for Semiconductor Lasers

  • Chen, Han;Qiao, Qinliang;Min, Jing;He, Cong;Zhang, Yuanyuan
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.384-390
    • /
    • 2021
  • This paper presents a wide-range tunable wavelength-locking technology based on optoelectronic oscillation (OEO) loops for optical fiber sensors and microwave photonics applications, explains the theoretical fundamentals of the design, and demonstrates a method for locking the relative wavelength differences between a leader semiconductor laser and its follower lasers. The input of the OEO loop in the proposed scheme (the relative wavelength difference) determines the radio-frequency (RF) signal frequency of the oscillation output, which is quantized into an injection current signal for feedback to control the wavelength drift of follower lasers so that they follow the wavelength change of the leader laser. The results from a 10-hour continuous experiment in a field environment show that the wavelength-locking accuracy reached ±0.38 GHz with an Allan deviation of 6.1 pm over 2 hours, and the wavelength jitter between the leader and follower lasers was suppressed within 0.01 nm, even though the test equipment was not isolated from vibrations and the temperature was not controlled. Moreover, the tunable range of wavelength locking was maintained from 10 to 17 nm for nonideal electrical devices with limited bandwidth.

산림지역 수목의 기하학적 구조 측정을 위한 휴대용 라이다 장비의 활용성 평가 (Assessment on the Applicability of a Handheld LiDAR for Measuring the Geometric Structures of Forest Trees)

  • 최승운;김태근;김종필;김성재
    • 한국지리정보학회지
    • /
    • 제25권2호
    • /
    • pp.48-58
    • /
    • 2022
  • 본 연구에서는 흉고직경, 수고 등 산림지역 수목의 기하학적 구조 측정을 위한 휴대용 라이다 장비의 활용성을 평가하였다. 휴대용 라이다 장비의 정확도를 파악하기 위하여 태백산국립공원 내 대상지역(30m×30m)을 선정하고 매목조사를 통해 흉고직경과 수고를 측정하였다. 또, 라이다 장비의 활용성에 대한 객관적인 평가를 위해 편향, 평균제곱근오차, 절대평균오차, 상관계수 등 4가지 통계지표를 활용하였다. 분석결과, 흉고직경의 경우 매목조사와 휴대용 라이다 장비를 이용한 측정치가 거의 유사한 것으로 나타났으며, 휴대용 라이다 장비는 기존의 조사방식을 대체하기에 충분하였다. 그러나, 매목조사에 의한 수고 측정치는 다양한 오차를 포함하고 있어 라이다의 정확도를 파악하기에는 한계가 있었다. 향후 보다 신뢰성 있는 수고 측정방법을 통해 수집된 자료로부터 라이다 장비의 정확도를 평가하는 연구가 필요할 것으로 생각된다.

Compact and precision range finder using self-mixing semiconductor laser

  • Shinohara, Shigenobu;Andou, Minoru;Yoshida, Hirofumi;Ikeda, Hiroaki;Miyata, Masafumi;Yoshida, Jun-Ichi;Nishide, Ken-Ichi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.972-978
    • /
    • 1989
  • Proposed is improved compact self-mixing type semiconductor-laser range finder, which measures mode-hop time interval (MHI). Measurement error caused by the fluctuation of MHI is greatly reduced by averaging many contiguous MHI's. The main cause of measurement error 1.5% at ranges from 0.1m to 0.8m is attributed to the optical phase change of a returned light from a focusing lens. Accuracy improvement by stabilization of the returned light is suggested.

  • PDF