• 제목/요약/키워드: Instantaneous operation

검색결과 134건 처리시간 0.024초

저속박용디젤기관의 순간회전속도 변동에 관한 연구 (Instantaneous Speed Variation of Crankshaft on a Low Speed Marine Diesel Engine)

  • 최재성;이진욱;이상득;조권회
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.138-144
    • /
    • 2007
  • The variation of the crankshaft speed in a multi-cylinder engine is determined by the resultant gas pressure torque and the torsional deformation of the crankshaft. Under steady state operation, the crankshaft speed has a quasi-periodic variation. For the diagnosis the engine instantaneous speed versus crankshaft angle is utilized. This paper describes a simple measurement method of the engine instantaneous speed versus crankshaft angle using the teeth on the flywheel of the crankshaft. Two non-contacting magnetic pickup combinations detect the crank angle and TDC position for the data acquisition. The results from experiments on a 6 cylinder marine diesel engine demonstrate that the crankshaft speed variation are detected with good resolution. And the crankshaft speed variation is investigated according to the operation conditions. Also, it is confirmed that the engine output measured by EMS can be evaluated larger than the actual value due to TDC position error caused by instantaneous speed variation.

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

Graphical Representation of the Instantaneous Compensation Power Flow for Single-Phase Active Power Filters

  • Jung, Young-Gook
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1380-1388
    • /
    • 2013
  • The conventional graphical representation of the instantaneous compensation power flow for single-phase active power filters(APFs) simply represents the active power flow and the reactive power flow which flowing between the power source and the active filter / the load. But, this method does not provide the information about the rectification mode and the compensation mode of APFs, especially, the loss for each mode was not considered at all. This is very important to understand the compensation operation characteristics of APFs. Therefore, this paper proposes the graphical representation of the instantaneous compensation power flow for single-phase APFs considering the instantaneous rectification mode and the instantaneous inversion mode. Three cases are verified in this paper - without compensation, with compensation of the active power 'p' and the fundamental reactive power 'q', and with compensation of only the distorted power 'h'. To ensure the validity of the proposed approach, PSIM simulation is achieved. As a result, we could confirm that the proposed approach was easy to explain the instantaneous compensation power flow considering the instantaneous rectification mode and the instantaneous inversion mode of APFs, also, Total Harmonic Distortion(THD)/Power Factor (P.F) and Fast Fourier Transform(FFT) analysis were compared for each case.

직분식 단기통 디젤기관 피스톤의 순간온도 측정에 관한 실험적 연구 (An Experimental Study on the Measurement of the Instantaneous Surface Temperature of the Piston of the DI Mono Cylinder Diesel Engine)

  • 이재순;이현구;강태경;이응래;정인곤;안병태
    • 한국자동차공학회논문집
    • /
    • 제6권1호
    • /
    • pp.196-204
    • /
    • 1998
  • For the experimental measurement of instantaneous surface temperature of the piston of the DI mono cylinder diesel engine, the instantaneous temperature proves, data acquisition system, and grass-hopper type linkage system were developed. The instantaneous temperatures on the piston bowl, crown, lands and skirt were measured and analyzed, and the following conclusions were derived ; (i) The crank angle for the maximum instantaneous temperature during one cycle varies and moves back and forth by the measuring positions and engine speeds. (ii) The engine speeds, the positions of the measuring points and the cooling water temperature had an effect on the instantaneous temperature amplitude. (iii) The instantaneous temperature suing phenomena appeared on the temperature profiles of the piston crown, top and second land of ring, but on the temperature profiles of the parts of the third land of the fing and skirt, they didn't appear, (iv) The isothermal lines in the piston were acquired through the operation of the finite elements method using the measured temperatures as the boundary conditions.

  • PDF

인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석 (Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods)

  • 김윤호;윤병도;이병순
    • 대한전기학회논문지
    • /
    • 제41권6호
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF

태양광 발전용 순시치 전류제어형 인버터의 특성 해석 (Analysist of Instantaneous Current Tracking Control Inverter Characteristics for Photovoltaic System)

  • 조금배;김한성
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.770-778
    • /
    • 1994
  • In this paper, the photovoltaic inverter system with instantaneous sinusoidal current tracking control is proposed to improve the utilization factor of photovoltaic power system which would be connected utility interactive system. The proposed inverter is designed to track maximum power point by two-state value control method and utility interactive operation, and to decrease output harmonics component. Optimal operating region is described by state space averaging method, and present tracking condition of standard guide line. The experimental result shows the effectiveness of inverter system using the instantaneous control method.

Measurement of suction air amount at reciprocating engine under stationary and transient operation

  • Kubota, Yuzuru;Hayashi, Shigenobu;Kajitani, Shuichi;Sawa, Norihiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1037-1042
    • /
    • 1990
  • The air-fuel ratio of an internal combustion engine must be controlled with accuracy for the improvements of exhaust emission and fuel consumption. Therefore, it is necessary to measure the exact instantaneous amounts of fuel and suction air, so we carried out the experiments for measuring the air flow velocity in a suction pipe of an internal combustion engine using three types of instantaneous air flowmeter. The results obtained can be summarized as follows: (1) The laminar-flow type flowmeter is able to measure both the average and the instantaneous flow rate, but it is necessary to rectify the pulsating air flow in the suction pipe. (2) The a spark-discharge type flow velocity meter is able to measure the instantaneous air velocity, but it is necessary to choose the suitable electrode form and the spark character. (3) The tandem-type hot-wire flow velocity meter indicates the instantaneous flow velocity and its flow direction.

  • PDF

Actiwatch 를 이용한 철도소음에 의한 수면방해의 정량적 평가 (Assessment of Sleep Disturbance on Night-time Instantaneous Railway Noise by using Actiwatch)

  • 홍지영;김재환;임창우;김규태;성동원;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.759-763
    • /
    • 2006
  • The World Health Organization(WHO) has recommended population of sleep disturbance as one of the environmental health indicators. But the percentage of respondents who felt highly sleep disturbed, that is, %HSD can???thave application to sleep disturbance from instantaneous noise. Therefore, this study has been carried out to present the technique for assessing sleep disturbance on instantaneous noise quantitatively. The study of sleep disturbance on night time instantaneous railway noise has been undertaken. Noise monitor has been in operation from 22 hours to 7 hours during 6 nights at 12 locations. To assess instantaneous noise induced sleep disturbance, it was decided to measure body movement by actiwatch. %motility was used as indicators of sleep disturbance. %motility is the expected value of probability of motility value during 7 epochs (105s) of any noise event. The measures of instantaneous motility have been related to measures of instantaneous railway noise events. The relationship shows that %motility is a good predictor for assessing sleep disturbance and Korean is more sensitive to noise than European although the railway noise have been considered in this study. This study can be extended to assessing long-term sleep disturbance and give a guideline far policy decision.

  • PDF

시간영역에서 순시 유효/무효전력을 이용한 마이크로그리드의 단독운전 판단 (Islanding Detection for a Micro-Grid based on the Instantaneous Active and Reactive Powers in the Time Domain)

  • 이영귀;김연희;정태영;김태현;강용철
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.22-27
    • /
    • 2012
  • Correct and fast detection of a micro-grid (MG) islanding is essential to the MG since operation, control and protection of the MG depend on an operating mode i.e., an interconnected mode or an islanding mode. When islanding occurs, the frequency of the point of common coupling (PCC) is not the nominal frequency during the transient state owing to the frequency rise or drop of generators in the MG. Thus, the active and reactive power calculated by the frequency domain based method such as Fourier Transform might contain some errors. This paper proposes an islanding detection algorithm for the MG based on the instantaneous active and reactive powers delivered to the dedicated line in the time domain. During the islanding mode, the instantaneous active and reactive powers delivered to the dedicated line are constants, which depend on the voltage of the PCC and the impedance of the dedicated line. In this paper, the instantaneous active and reactive powers are calculated in the time domain and used to detect islanding. The performance of the proposed algorithm is verified under various scenarios including islanding conditions, fault conditions and load variation using the PSCAD/EMTDC simulator. The results indicate that the algorithm successfully detects islanding for the MG.