• Title/Summary/Keyword: Installed performance

Search Result 2,745, Processing Time 0.028 seconds

Numerical Study on Performance Evaluation of Impact Beam for Automotive Side-Door using Fiber Metal Laminate (자동차 측면 도어의 섬유금속적층판을 적용한 임펙트 빔의 수치해석에 의한 성능 평가)

  • Park, Eu-Tteum;Kim, Jeong;Kang, Beom-Soo;Song, Woo-Jin
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.158-164
    • /
    • 2017
  • The fiber metal laminate is a type of hybrid materials laminated thin metallic sheets with fiber reinforced plastic sheets. The laminate has been researched or applied in automotive and aerospace industries due to their outstanding impact absorbing performance in view of light weight aspect. Specially, the replacement of side-impact beam as the fiber reinforced plastic has been researched actively. The objective of this paper is the primitive investigation in the development of side-door impact beam using the fiber metal laminate. First, the three-point bending simulations were conducted to decide the shape of impact beam using the numerical analysis. Next, two cases impact beam (pure DP 980 and fiber metal laminate) were installed in the side-door, and then the bending tests (according to FMVSS 214S) were simulated using the numerical analysis. It is noted that the side-door impact beam can be replaced with the fiber metal laminate sufficiently based on the numerical analysis results.

An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House (단독주택용 태양열/지열 융복합시스템의 태양열 급탕성능 평가)

  • Baek, Namchoon;Han, Seunghyun;Lee, Wang Je;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.581-586
    • /
    • 2015
  • In this study, an analysis was performed on the performance of the solar water heating system with geo-thermal heat pump for a detached house. This system has a flat plate solar collector ($8\;m^2$) and a 3 RT heat pump. The heat pump acts as an auxiliary heater of the solar water heating system. These systems were installed at four individual houses with the same area of $100\;m^2$. The monitoring results for one year are as follows. (1) The average daily operating time of the solar system appeared to be 313 minutes in spring (intermediate season), and 135 minutes and 76 minutes in winter and summer respectively. The reason for the short operating time in summer is the high storage temperature due to low water heating load. The high storage temperature is caused by a decrease in collecting efficiency as well as by overheating. (2) The geothermal heat pump as an auxiliary heater mainly operates on days of poor insolation during the winter season. (3) Despite controlling for total house area, hot water consumption varies greatly according to the number of people in the family, hot water usage habits, etc. (4) The yearly solar fraction was 69.8 to 91.5 percent, which exceeds the maximum value of 80% as recommended by ASHRAE. So the solar collector area of $8\;m^2$ appeared to be somewhat greater for the house with an area of $100\;m^2$. (5) The observed annual efficiency of solar systems was relatively low at 13.5 to 23.6%, which was analyzed to be due to the decrease in thermal efficiency and the overheating caused by a high solar fraction.

Early Age Behavior of Thin Bonded Continuously Reinforced Concrete Overlay on Aged Jointed Plain Concrete Pavement (노후 줄눈 콘크리트 포장 보수를 위한 얇은 연속 철근 콘크리트 덧씌우기 포장의 초기거동 평가)

  • Ryu, Sung-Woo;Nam, Jung-Hee;Kim, Ki-Heun;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.121-132
    • /
    • 2009
  • Thin bonded continuously reinforced concrete overlay(CRCO) was constructed on He existing jointed plain concrete pavement(HCP) surface at Seo-Hae-Ahn express highway in South Korea in order to evaluate its applicability and performance. Two sections of road were considered for this evaluation. In the first section, the concrete overlayer was placed and cut down to the existing layer to form transverse joints while CRCO was constructed on top of the existing layer in the second section. Early strength concrete(Type III) was utilized for both overlay sections. The depth of milling and the thickness of overlaid layer were 5 cm and 10 cm, respectively. Several vibrating wire gauges(VWG) were installed to evaluate the performance of CRCO with respect to curling, delamination, and crack propagation. As a result of the strength test, it was found that strength of the material reaches the design criteria within 1-3 days. Analysis with vibrating wire gauge(VWG) showed CRCO effectively restricts joint movement. High adhesive strength also was observed from the material regardless of length of aging. Meanwhile, transverse cracks were observed on the middle of the section where JPCP overlay was applied whereas arbitrarily cracks in transverse direction were observed on the section where CRCP was applied.

  • PDF

Reliability Evaluation of ACP Component under a Radiation Environment (방사선환경에서 ACP 주요부품의 신뢰도 평가)

  • Lee, Hyo-Jik;Yoon, Kwang-Ho;Lim, Kwang-Mook;Park, Byung-Suk;Yoon, Ji-Sup
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.4
    • /
    • pp.309-322
    • /
    • 2007
  • This study deals with the irradiation effects on some selected components which are being used in an Advanced Spent Fuel Conditioning Process (ACP). Irradiation test components have a higher priority from the aspect of their reliability because their degradation or failure is able to critically affect the performance of an ACP equipment. Components that we chose for the irradiation tests were the AC servo motor, potentiometer, thermocouples, accelerometer and CCD camera. ACP facility has a number of AC servo motors to move the joints of a manipulator and to operate process equipment. Potentiometers are used for a measurement of several joint angles in a manipulator. Thermocouples are used for a temperature measurement in an electrolytic reduction reactor, a vol-oxidation reactor and a molten salt transfer line. An accelerometer is installed in a slitting machine to forecast an incipient failure during a slitting process. A small CCD camera is used for an in-situ vision monitoring between ACP campaigns. We made use of a gamma-irradiation facility with cobalt-60 source for an irradiation test on the above components because gamma rays from among various radioactive rays are the most significant for electric, electronic and robotic components. Irradiation tests were carried out for enough long time for total doses to be over expected threshold values. Other components except the CCD camera showed a very high radiation hardening characteristic. Characteristic changes at different total doses were investigated and threshold values to warrant at least their performance without a deterioration were evaluated as a result of the irradiation tests.

  • PDF

Task-Visual Information Map to Develop AR Navigators of Construction Equipment (건설장비 AR 네비게이터 개발을 위한 작업-시각정보 맵 도출)

  • Song, Sujin;Kang, Hojun;Kim, Hanbeen;Moon, Taenam;Shin, Do Hyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.3
    • /
    • pp.116-124
    • /
    • 2016
  • Work efficiency of earth work which is one of the main works occurring in construction site mainly depends on the performance of individual operators of earth work equipment. Consequently, the skill of individual operators of earth work equipment can significantly affect overall construction schedules. Many invisible areas inevitably exist in construction site because of the nature of construction site where occlusions occur from structures being built, installed or moving equipment, moving workers, etc. The lack of visual information regarding tasks critically impedes the effective performance of operators of earth work equipment. AR (Augmented Reality) is a computer technology that superimposes virtual objects onto the real world scene. This characteristic of AR may address the lack of visual informations in earth work process, thus helping to improve the work efficiency of operators of earth work equipment. The purpose of this study is to present a task-visual information map that identifies visual informations required in tasks of earth work and which of the tasks are suitable for AR technology. This study focuses on visual informations in tasks of earth work with excavators. The map was created based on the investigations on the problems of each task of earth work with excavators and visual informations required to address the problems. Through the map, four visual informations were found to be suitable for AR technology to improve the work efficiency of excavator operators. Based on the findings of this study, AR systems for excavators can be developed more effectively.

Design and fundamental test on the cargo pump sump scaled model of tankers (탱크선 카고 펌프장 축소모델 설계 및 기초 실험)

  • Lee, Jo-Yeon;Kim, Seung-Jun;Chen, Zhenmu;Singh, Patrick Mark;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.31-35
    • /
    • 2017
  • The internal flow of a pump system that is installed in the interior of large vessels such as tankers is largely affected by the water level and flow conditions of the pump sump. However, the performance of the pump is generally evaluated with the consideration of only the performance of the pump itself, without considering the pumping station operating environment. Therefore, if the pump is affected by the incoming flow that exhibits vortex and swirl, the occurrence of vortex and swirl accompanied with air may cause problems with the pump sump. This effect of flow condition can lead to a decrease in efficiency, increase in vibration, and noise generation in the pump. In this study, to investigate the internal flow of the pump sump according to several water levels, a pump sump scale-model was designed and constructed. The frequency of vortex occurrence and the shape of the vortex were investigated according to the different water levels of a fundamental test. The Class C vortex type, which has a larger volume of air intake to the pump, was confirmed by the higher occurrence frequency at a relatively lower water level.

A Study on Connection of Fuel Processor and NG blower for Small Commercial Fuel Cell System (건물용 연료전지 시스템용 연료처리장치와 연료승압 블로워 연계 특성에 관한 연구)

  • Kim, Jaedong;Jang, Sejin;Kim, Bonggyu;Kim, Jinwook;Han, Sienho;Park, Dalryung
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.36-44
    • /
    • 2017
  • The small commercial fuel cell is a new energy system that produces electricity and heat through electrochemical reaction between air and hydrogen. In Korea, hundreds of domestic small commercial fuel cell systems have been installed and operated every years and many parts in fuel cell systems depend on overseas products. KOGAS(Korea Gas Corporation) has developed the fuel processor which is an important part of fuel cell system and has evaluated the long-term durability. And KOGAS has evaluated domestic and overseas NG blower and fuel processor connected to NG blower. The fuel processor developed by KOGAS have maintained an efficiency of 76% and constant performance over 3,000 hours. The NG blower developed in Korea showed similar characteristics as overseas NG blower in the evaluation of power consumption according to rear pressure and outside temperature. The fuel processor module, fuel processor connected to BOP showed excellent performance.

Studies on Raw-Water Source Heat Pump Equipped with Thermal Storage Tank in Water Treatment Facility (정수장 내 축열조 설치 원수열원 히트펌프의 성능분석)

  • Oh, Sun Hee;Yun, Rin;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.467-472
    • /
    • 2013
  • A raw-water source heat pump equipped with a thermal storage tank was dynamically simulated by TRNSYS, and the results were verified by using the data from a heat pump installed in the Seongnam water treatment facility. The average coefficient of performance (COP) of the raw-water source heat pump based on simulation was 4.97 and 3.17 in the cooling and heating season, respectively. When the volume of the thermal storage tank was changed from 5 to $20m^3$, the highest COP was found at a size of $10m^3$. Considering the regional locations of raw-water source heat pumps at Seoul, Incheon, Gangneung, and Gwangju, Seoul showed the lowest electric power consumption in the cooling season and the highest in the heating season. When a comparison of the performance between the present system and that of a water-air heat pump was conducted, the present system showed lower electric power consumption by 25% than that of a water-air heat pump.

Performance test of double swirl burner for the development of pilot scale compact gasifier (컴팩트 석탄 가스화기 개발을 위한 이중선회버너 운전 평가)

  • Kang, Suk-Hwan;Ryu, Jae-Hong;Chung, Seok-Woo;Jung, Woo-Hyun;Yoo, Sang-Oh;Lee, Do-Yeon;Yun, Yongseung;Lee, Jin-Wook;Kim, Gyoo-Tae;Yi, Min-Hoe
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.96-104
    • /
    • 2013
  • Coal gasification is considered as one of the best alternatives among clean coal technology and new concept next generation technologies are under being developed to achieve low cost as well as high efficiency. In this study we have developed double swirl multi-burner as part of the development of low cost compact gasifier. We installed new concept multi-burner with pulverized coal distributor to the body of existing gasifier for burner test. Gasification test was performed under the condition of $6.4{\sim}7.2kg/cm^2$ and $1170{\sim}1300^{\circ}C$ by using Indonesian ABK (sub-bituminous) coal to get operation condition of new concept multi-burner. Our interest was focused to ensure a stable operating condition rather than the gasifier performance evaluation. As a result, we were able to achieve the carbon conversion of 84% and the cold gas efficiency of 52.1% at the stable operating conditions.

OPTICAL PROPERTY AND ALIGNMENT OF KAO WIDE FIELD TELESCOPE (NEOPAT-3) (광시야 망원경 3호기 (NEOPAT-3)의 광학계 특성 및 조정)

  • Yuk, In-Soo;Kyeong, Jae-Mann;Yoon, Joh-Na;Yoon, Jae-Hyuck;Yim, Hong-Suh;Moon, Hong-Kyu;Han, Won-Yong;Byun, Yon-Ik;Kang, Yong-Woo;Yu, Sung-Yeol
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.417-428
    • /
    • 2004
  • We have investigated the optical property of the KAO(Korea Astronomy Observatory) wide field telescope (named NEOPAT-3; Near Earth Object and Satellite Patrol-3) and aligned optical system. The NEOPAT-3 is restricted to V,R,I-filters because of the refractive property of the correcting lens system. Because of the fast focal ratio, the optical performance of the NEOPAT-3 is very sensitive to its alignment factors of the optical system. To make the spot radius smaller than $8{\mu}m$ in rms over 2degree${\times}2$degree field, the optical system must satisfy the following conditions: 1) The tilt error between detector plane and focal plane should be less than 0.05degree. 2) The decenter error between the primary mirror and the correcting lens system should be less than 1mm. 3) The distance error between the primary mirror and the correcting lens system should be less than 2.3mm. In order to align the optical system accurately, we measured the aberrations of the telescope quantitatively by means of curvature sensing technique. NEOPAT-3 is installed temporary on the roof of the TRAO(Taeduk Radio Astronomy Observatory) main building to normalize system performance and to develop automatic observation.