• 제목/요약/키워드: Installed performance

검색결과 2,743건 처리시간 0.028초

지진격리 구조물의 지진모니터링 시스템 개발 (The Development of Seismic Monitoring for a Base-Isolated Building System)

  • 김성훈;조대승;박해동;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.247-251
    • /
    • 2001
  • Nowadays, base isolation systems such as lead-rubber bearing, elastomer bearing and sliding bearing have been installed to the various structures to prevent the disaster from seismic. The performance of base isolation system have been well proved by model-scale experiments and numerical analysis. However. the seismic response data measured at real large base-isolated structures is still insufficient. This paper presents a seismic monitoring system, acquiring real-time acceleration signals up to 32 channels, displaying time history and spectrum of the signals, storing the acquired data at a PC hard disk, and replaying the saved data. Moreover, the system can be operated without any limitation for monitoring period by automatic management of stored data file. The developed system has been installed at a real base-isolated building using lead-rubber bearings and we expect its seismic response data with ground motion signal can be well licquired in case of earthquake occurrence.

  • PDF

CFD analysis of the effect of different PAR locations against hydrogen recombination rate

  • Lee, Khor Chong;Ryu, Myungrok;Park, Kweonha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권2호
    • /
    • pp.112-119
    • /
    • 2016
  • Many studies have been conducted on the performance of a passive autocatalytic recombiner (PAR), but not many have focused on the locations where the PAR is installed. During a severe accident in a nuclear reactor containment, a large amount of hydrogen gas can be produced and released into the containment, leading to hydrogen deflagration or a detonation. A PAR is a hydrogen mitigation method that is widely implemented in current and advanced light water reactors. Therefore, for this study, a PAR was installed at different locations in order to investigate the difference in hydrogen reduction rate. The results indicate that the hydrogen reduction rate of a PAR is proportional to the distance between the hydrogen induction location and the bottom wall.

수중 하베스트형 빙축열시스템의 축방냉 특성 실험 (Experiment on the Charge and Discharge of Thermal Energy for Under-Water Harvest-Type Ice Storage System)

  • 김재돌
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.11-17
    • /
    • 2002
  • This paper is concerned with the development of a new method for making, separating ice and storage floated ice by installing an evaporation plate at under-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating an ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. Developed new harvest-type method shows good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, however these components are not necessary in a new method. In this study ice storage systems are experimentally investigated to study the charge and discharge of thermal energy. The results show the applicable possibility and performance enhancement of a new type.

지중열교환기의 지중열전도도 성능 분석 (Performance Analysis of Ground Thermal Conductivity by Ground Heat Exchanger)

  • 김영준;최재상;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2005
  • The objectives of this paper are to estimate the ground thermal conductivity by ground heat exchangers in two different places - Chooncheon and Wonjoo, and to analyze the effect of ground thermal conductivity on the ground thermal diffusivity and the size of the ground heat exchanger. In Chooncheon area, a single-U type HDPE pipe (25mm diameter) with borehole diameter of 150mm, length of 150m is installed. In Wonjoo area, a single-U type HDPE pipe (40mm diameter) with borehole diameter 150mm, length of 200m is installed. It is found that the ground thermal conductivities are estimated as 2.69 $W/m^{\circ}C$ and 2.99 $W/m^{\circ}C$ in Chooncheon and Wonjoo, respectively. It is also found that the ground heat exchanger size is reduced by 8.6% with 25% increase of ground thermal conductivity, and increase by 11.8% with 25% decrease of ground thermal conductivity.

  • PDF

우수토실에 설치된 월류수 제어를 위한 유입유량조절장치의 개선효과 (Improvements of Inflow Controller Installed in Storm Overflow Diverging Tank for CSOs Control)

  • 임봉수;박윤해;김태응
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.428-435
    • /
    • 2015
  • This study was carried out to evaluate the performance of a inflow controller for the control of combined sewer overflows (CSOs). Because of the inflow controller could be adjusted manually by predicting the maximum amount of peak flow, the mechanical adjustment of this controller was higher than the existing fixed-type controller in field application. Standardizing the relationship between the flow and the clearance and angle of an inlet cover plate on the inflow conditions can selected to the optimum conditions for the on-site. It was concluded that BOD pollutant loading at the region in which inflow controller was installed had shown the removal efficiency rate of 42%.

철도신호설비용 낙뢰방호장치의 건설 (Construction of Lightning Protection System for Railway Signaling Equipments)

  • 최규형;서석철;최세완
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1193-1198
    • /
    • 2004
  • This paper describes the lightning protection system for railway signaling equipments installed at subway car depots in Seoul metropolitan Rapid Transit Cooperation. Several measures for improving lightning protection performance are adopted; newly organized grounding system for neutral line of power system, rolling method to minimize damages induced by direct lightning strike, new measures to reduce voltage differences between the signaling equipments and the ground, and improvement of grounding system. The proposed system has greatly reduced the grounding resistance and also the voltage difference between the signaling equipments and the ground, and has prevented the accident related with lightning surges since it was installed. The proposed approach can be viewed as a useful alternative of dealing with lightning protection for railway signaling equipments.

  • PDF

무인 자율 주행 차량 시스템 설계 및 제어에 관한 연구 (A Study on the Design and Control Method for Unmanned Ground Vehicle System)

  • 문희창;박명욱;김정하
    • 제어로봇시스템학회논문지
    • /
    • 제16권5호
    • /
    • pp.446-455
    • /
    • 2010
  • The research presented covers the design and control method of unmanned ground vehicle (UGV). An electric vehicle is used and is driven by DC motor. The power system on the UGV has been adjusted and actuators have been installed for steering and brake automation. A toggle switch is implemented to easily switch between manual and autonomous states. The UGV state is monitored by a velocity sensor, as well as steering and brake position sensors. An emergency stop device was designed and installed to quickly and safely stop the UGV. Different control methods, including the PID controller, were studied for improved steering responsiveness, and results were confirmed through experimentation. Satisfactory performance was achieved and several possible areas of future research have arisen.

초고층공동주택 국소배기용 입상덕트시스템의 제어성능평가에 관한 연구 (Study on the Control Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;안정헌
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.103-108
    • /
    • 2009
  • Local exhaust system used in toilet and cooking place of low-rise public house installed roof ventilator at terminal of stack. There are many high riser public houses in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser public house depends on stack effect. But Neutral pressure level represents in a terminal of stack with air tightness for the best exhaust efficiency. Thereby, lower floors have the worst indoor air quality. This paper focuses mainly on the exhaust efficiency improved by roof fan with motor installed in high riser public house. It is observed there is higher exhaust efficiency than the existing natural roof ventilator.

전기철도 교/직 절연구분장치의 절연열화 현상 (Insulation Deterioration of AC/DC Section Insulators for Electric Railroad Catenary.)

  • 최규형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.16-22
    • /
    • 2003
  • While passing through the AC/DC section insulators installed at electric railroad catenary, some electric trains undergo mis-operation of main circuit breaker after AC/DC change-over operation. This paper provides insulation resistance measurements of AC/DC section insulators, which confirm the insulation levels of section insulators are below the standard of insulators. The insulation deterioration and pantograph arrangement on the electric train can produce voltage impression on section insulator which induces mis-operation of main circuit breaker To mitigate the insulation deterioration of the section insulator installed at underground railroads, the section insulators have been cleaned periodically, but section insulator structure should be modified to make the section insulator performance perfect. Based on the above analysis, effective modification method of AC/DC section insulator is provided.

교량시설물 안전관리 네트워크 구축을 위한 기존 시스템 연계방안 연구 (Connection method on pre-installed bridge monitoring system for bridge structure safety network)

  • 박기태;이우상;주봉철;황윤국
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.469-472
    • /
    • 2008
  • In general, structures in service gradually lose original performance according to time due to initial defects in design and construction, or exposure to unfavorable external conditions such as repeated loading or deteriorating environment, and in extreme cases, may collapse in large disaster. Therefore, in order to maintain the serviceability of structures at optimal level, advanced structure measuring system which can inform optimal time point and method of maintenance is required in addition to accurate prediction of residual life the structure by periodic inspection. To guarantee the safety level of bridge structure and to prevent from disaster, the integration of safety network for bridge structures are needed. Therefore in this study, to enhance the effectiveness of safety network for bridge, the connection methodologies between safety network and pre-installed bridge monitoring system are investigated.

  • PDF