• Title/Summary/Keyword: Installed performance

Search Result 2,743, Processing Time 0.045 seconds

Load Balancing Algorithm for Parallel Computing of Design Problem involving Multi-Disciplinary Analysis (다분야통합해석에 기반한 설계문제의 병렬처리를 위한 부하분산알고리즘)

  • Cho, Jae-Suk;Chu, Min-Sik;Song, Yong-Ho;Choi, Dong-Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.327-332
    • /
    • 2007
  • An engineering design problem involving Multi-Disciplinary Analysis(MDA) generally requires a large amounts of CPU time for the entire design process, and therefore Multiple Processing System (MPS) are essential to reduce the completion time. However, when applying conventional parallel processing techniques, all of the CAE S/W required for the MDA should be installed on all the servers making up NIPS because of characteristic of MDA and it would be a great expense in CAE S/W licenses. To solve this problem, we propose a Weight-based Multiqueue Load Balancing algorithm for a heterogeneous MPS where performance of servers and CAE S/W installed on each server are different of each other. To validate the performance, a computational experiments comparing the First Come First Serve algorithm and our proposed algorithm was accomplished.

  • PDF

Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table (조리대에 급기구를 가진 주방 레인지후드의 배기 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.

Performance Test of Noise Reducers Installed on Noise Barrier (방음벽 상단의 소음감소기 성능 평가)

  • Kang, Daejoon;Lee, J.W.;Gu, J.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.570-574
    • /
    • 2013
  • The use of noise barrier is being increased to reduce the environmental noise in these days. Also, many noise reducers installed at the top of noise barrier are developed for improving the efficiency of noise reduction. So we evaluate the performance of the noise reducers and compare the results among the others. Results of field tests show that the insertion loss due to the noise reducers is up to 10.6 dB.

  • PDF

Installation and Performance Evaluation of 100kWp PV System in Tibet (중국 티베트지역의 100kWp급 태양광발전시스템 실증연구)

  • Kim, Seok-Ki;Yun, Jae-Ho;Lee, Jeong-Chul;Aha, Se-Jin;Yoon, Kyung-Hoon;Song, Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.125-129
    • /
    • 2006
  • This paper presents the isolation and performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module by using Koreans solar cells, constructed site and built control house.

  • PDF

KOMPSAT-2 Terminal for Polar Station (K2PS) Development by KARI

  • Koo, In-Hoi;Kang, Ji-Hoon;Bae, Hee-Jin;Ahn, Sang-Il
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.409-416
    • /
    • 2008
  • Recently, KARI developed "KOMPSAT-2 Terminal for Polar Station" which is high performance system newly required for stimulating KOMPSAT-2 application. The KOMPSAT-2 Terminal for Polar Station consists of one receiving system and two processing systems. The receiving system has been installed at Svalbard Satellite Station located at Norwegian Svalbard island. and the two receiving systems have been installed at Kongsberg Satellite Service AS located at Tromso Norway and Spot Image SA located at Toulouse France respectively. In this paper overall items of KOMPSAT-2 Terminal for Polar Station, which includes requirements, designs and operation concepts, are to be addressed with the verification result on its performance.

Study of Earthquake Resilient RC Shear Wall Structures

  • Jiang, Huanjun;Li, Shurong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.211-218
    • /
    • 2021
  • A new type of earthquake resilient reinforced concrete (RC) shear wall structure, installed with replaceable coupling beams and replaceable corner components at the bottom of wall piers, is proposed in this study. At first, the mechanical behavior of replaceable components, such as combined dampers and replaceable corner component, is studied by cyclic loading tests on them. Then, cycling loading tests are conducted on one conventional coupled shear wall and one new type of coupled shear wall with replaceable components. The test results indicate that the damage of the new type of coupled shear wall concentrates on replaceable components and the left parts are well protected. Finally, a case study is introduced. The responses of one conventional frame-tube structure and one new type of structure installed with replaceable components under the wind and the earthquake are compared, which verify that the performance of new type of structure is much better than the conventional structure.

Installation and Performance Test of Cooling System for the KEPCO HTS Power Cable (한전 초전도 전력케이블 냉각시스템 설치 및 시험)

  • Yang, H.S.;Kim, D.L.;Lee, B.S.;Choi, Y.S.;Ryoo, H.S.;Sohn, S.H.;Lim, J.H.;Hwang, S.D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.82-85
    • /
    • 2007
  • A cooling system for a 22.9kV, 1.25kA 100m HTS power cable has been installed and tested. The cooling system consists of decompression cooling system with the cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. This paper describes the outline of the installed cooling system and performance test results.

Test Results of Dual-Use Wide-Area Differential GPS System for Extending the Operational Coverage

  • Kap Jin Kim;Jae Min Ahn
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.3
    • /
    • pp.307-314
    • /
    • 2023
  • Wide-Area Differential Global Positioning System (WADGPS) is a system that operates a number of reference stations to provide correction information to improve the accuracy of GPS users, and it is available to service users within the area where the wide-area reference stations are installed. Recently, as positioning information has been used in various applications, the need for WADGPS for precise navigation in long-distance spaced areas where the wide-area reference stations cannot be installed has been raised. This paper tested the user navigation performance outside the wide-area reference stations of the WADGPS system, which serves both GPS Precise Positioning Service (PPS) and Standard Positioning Service (SPS) users. Static and dynamic tests were conducted using vehicles, and as a result, position accuracy improvement through WADGPS was confirmed even at points hundreds of kilometers outside the network area of the wide-area reference stations. Through this, the performance of the PPS/SPS correction system and the possibility of expanding the service area were confirmed.

Heat/Mass Transfer on Effusion Plate with Circular Pin Fins for Impingement/Effusion Cooling System with Intial Crossflow (초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 원형핀이 설치된 유출면에서의 열/물질전달 특성)

  • Hong Sung Kook;Rhee Dong-Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.828-836
    • /
    • 2005
  • Impingement/effusion cooling technique is used for combustor liner or turbine parts cooling in gas turbine engine. In the impingement/effusion cooling system, the crossflow generated in the cooling channel induces an adverse effect on the cooling performance, which consequently affects the durability of the cooling system. In the present study, to reduce the adverse effect of the crossflow and improve the cooling performance, circular pin fins are installed in impingement/effusion cooling system and the heat transfer characteristics are investigated. The pin fins are installed between two perforated plates and the crossflow passes between these two plates. A blowing ratio is changed from 0.5 to 1.5 for the fixed jet Reynolds number of 10,000 and five circular pin fin arrangements are considered in this study. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The results show that local distributions of heat/mass transfer coefficient are changed due to the installation of pin fins. Due to the generation of vortex and wake by the pin fin, locally low heat/mass transfer regions are reduced. Moreover, the pin fin prevents the wall jet from being swept away, resulting in the increase of heat/mass transfer. When the pin fin is installed in front of the impinging let, the blockage effect on the crossflow enhances the heat/mass transfer. However, the pin fin installed just behind the impinging jet blocks up the wall jet, decreasing the heat/mass transfer. As the blowing ratio increases, the pin fins lead to the higher Sh value compared to the case without pin fins, inducing $16\%{\~}22\%$ enhancement of overall Sh value at high blowing ratio of M=1.5.