• 제목/요약/키워드: Installations Condition

검색결과 39건 처리시간 0.029초

경관조명기구의 설치에 대한 기준노임 산정에 관한 연구 (A study on the Assessment of Standard Wages for Constructing Luminaries for Landscope Lighting)

  • 유동길;이복희;이석연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 2008
  • Recently, landscape lighting is more and more installing in many places such as park, cultural heritages, large-scale structures, bridges, apartment, and so on. However, there is no the government-set official estimation for standard wages constructing luminaries for landscape lighting. The cost of construction is estimated based on the standard wages of related-similar installations such as internal lighting fixtures or the designer's subjective decision. Sometimes, it is overestimated or underestimated. In this paper, the fundamental process for estimating the standard wages constructing luminaries for landscape lighting is studied. The estimation method of standard wages constructing lighting fixtures was examined on the basis of the type and capacities of luminaries, installation places, type and shapes of installation auxiliary materials, worker's skill, and etc. As a result, some results obtained in this work were significantly, different with the standard wages for internal electric wiring published by Korea Electric Association. In the future, to improve the accuracy of the estimation of the standard wages for constructing luminaries for landscope lighting, detailed factors related to the installation condition and dimensions and types of luminaries should be considered.

  • PDF

적외선 열화상의 기상조건에 의한 영향 분석 (Analysis on the Effects by Weather Conditions of Infrared Thermography)

  • 임용배;최명일;김기현;박치현;배석명;조성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.99-102
    • /
    • 2007
  • Infrared thermography is one of the most valuable and cost-effective diagnostic techniques for predictive maintenance on electrical systems. For the installations, the thermography can identify major problems, which if left unattended could lead to breakdowns. The result thermal images depend upon operator skills, inspection technique, and weather conditions. When the thermographer is applied to remote monitoring, the conditions of the systems are not perfectly analyzed because operators are hard to know the weather effects of the installed place. Therefore, this paper defines the effect by weather conditions these factors will influence the final results. The purpose of this paper is to define the weather effects that a thermographer needs to consider for successful condition analysis.

  • PDF

아파트 전기설비에서의 고조파 실태 분석 연구 (A Study on the Harmonic of the electrical Installations in Apartment Housing)

  • 이기홍;성세진
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.105-110
    • /
    • 2001
  • 본 연구에서는 아파트의 각종 전력설비에서 고조파 실태와 영향을 파악하기 위하여 이를 측정하고 분석하였다. 그 결과 세대에 전력을 공급하는 전등전열변압기에서는 제5고조파, 동력변압기에서는 제5고조파 및 제7고조파가 많이 발생되는 것으로 분석되었다. 또한 아파트 수변전설비의 인입점에서 측정한 전압의 종합왜형률(THD) 은 평균 2.4[%]로서 비교적 양호한 것으로 나타났으나, 향후 가전기기의 대용량화 추세에 따라 아파트의 전력설비 계획에서도 고조파에 대한 고려가 필요한 것으로 분석되었다.

  • PDF

열열화된 PVC 케이블의 부분방전 진단 (Partial Discharge Diagnosis of Thermal Degradated PVC Cable)

  • 송기태;이성일
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.208-214
    • /
    • 2011
  • In this thesis, the partial discharge according to applied voltage and variations of cross-sectional area and length of the conductor related to general condition for using cable was measured in order to study degradation diagnosis for 2-Core cable of the PVC insulator used in industrial fields for other safety installations. Also the thermal degradation conditions under various installation circumstances of cables were studied by assuming degradation conditions with each different degradation rate (50%, 67%, 100%) such as variation in degradated temperature, thermal exposure time, normal state, partially degradated state and overall degradated state for thermal degradation diagnosis. The quantity of electric discharge (V-Q) according to applied voltage was measured for measurement of inception voltage and extinction voltage. The quantity of electric discharge and the number of electric discharge (Q-N) were measured with applied voltage kept constantly. In addition, pictures were taken using SEM (scanning electron microscope) to compare the surface of external insulator to degradated state of internal insulator according to thermal degradation temperature and also compare the surface of external insulator to degradated surface state of internal insulator according exposure time of cables to thermal stress.

Structural health monitoring of high-speed railway tracks using diffuse ultrasonic wave-based condition contrast: theory and validation

  • Wang, Kai;Cao, Wuxiong;Su, Zhongqing;Wang, Pengxiang;Zhang, Xiongjie;Chen, Lijun;Guan, Ruiqi;Lu, Ye
    • Smart Structures and Systems
    • /
    • 제26권2호
    • /
    • pp.227-239
    • /
    • 2020
  • Despite proven effectiveness and accuracy in laboratories, the existing damage assessment based on guided ultrasonic waves (GUWs) or acoustic emission (AE) confronts challenges when extended to real-world structural health monitoring (SHM) for railway tracks. Central to the concerns are the extremely complex signal appearance due to highly dispersive and multimodal wave features, restriction on transducer installations, and severe contaminations of ambient noise. It remains a critical yet unsolved problem along with recent attempts to implement SHM in bourgeoning high-speed railway (HSR). By leveraging authors' continued endeavours, an SHM framework, based on actively generated diffuse ultrasonic waves (DUWs) and a benchmark-free condition contrast algorithm, has been developed and deployed via an all-in-one SHM system. Miniaturized lead zirconate titanate (PZT) wafers are utilized to generate and acquire DUWs in long-range railway tracks. Fatigue cracks in the tracks show unique contact behaviours under different conditions of external loads and further disturb DUW propagation. By contrast DUW propagation traits, fatigue cracks in railway tracks can be characterised quantitatively and the holistic health status of the tracks can be evaluated in a real-time manner. Compared with GUW- or AE-based methods, the DUW-driven inspection philosophy exhibits immunity to ambient noise and measurement uncertainty, less dependence on baseline signals, use of significantly reduced number of transducers, and high robustness in atrocious engineering conditions. Conformance tests are performed on HSR tracks, in which the evolution of fatigue damage is monitored continuously and quantitatively, demonstrating effectiveness, adaptability, reliability and robustness of DUW-driven SHM towards HSR applications.

승강기작업자 안전사고예방을 위한 안전관리 개선 방안 (Safety Management Improvement Plan for Elevator Worker Safety Accident Prevention)

  • 김범상;박범
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.23-29
    • /
    • 2020
  • Korea's elevator industry is one of the world's eighth-largest industrial sectors and the third largest in the world by new installations. This year, the number of elevators has exceeded 700,000, and the number of new installations is 30,000-40,000 every year. However, the news of elevator-related accidents is reported continuously through the media and the accident rate is not decreasing. In particular, among the recent accidents related to elevators, accidents related to elevator workers are increasing, causing social problems. This year, the National Assembly's Environmental Labor Relations Commission's National Auditors lost five lives a year and 12 elevator workers were killed in fall and stenosis accidents during the installation, maintenance and replacement of the elevators for about two years since 2018. It took place to adopt the representatives of four domestic elevator companies as witnesses. An elevator worker is a collective term for workers involved in the design, manufacturing, installation, replacement, maintenance, inspection, management, and supervision related to the elevator industry, and the related accidents are called elevator worker accidents. Analysis of elevator-related accidents in the past has shown that the fault of the user accounted for 70% of the total, and the fault of the worker accounted for about 2.5%, and the accident occurred to the user or the user due to carelessness of the worker during the lift-related work. Currently, elevator-related accidents are reported by the Korea Elevator Safety Agency under Article 48 of the Elevator Safety Management Act under the Ministry of Interior and Safety. If deemed necessary for the prevention and prevention of recurrence of an elevator accident, the cause and condition of the elevator accident may be investigated. However, the current draft law is limited only to elevators after installation inspection, and is separated from the Ministry of Employment and Labor's data on accidents occurring in the manufacturing and installation stages related to the elevator industry. This study analyzes the recent safety accidents of elevator workers and prepares safety measures to prevent them through the risk analysis, and also draws out the problems and improvements of the current elevator worker accident investigation to find the elevator worker accident rate that is on the increase trend.

국방 시뮬레이션에서 무기효과 데이터 획득을 위한 MSDL의 확장 (An Extension of MSDL for Obtaining Weapon Effectiveness Data in a Military Simulation)

  • 이상진;오현식;김도형;이예림;이순주
    • 한국시뮬레이션학회논문지
    • /
    • 제30권2호
    • /
    • pp.1-9
    • /
    • 2021
  • 국방 모델링 및 시뮬레이션에서 교전상황을 모의할 때 바람의 방향이나 세기, 온도, 장애물과 같은 다양한 요소들이 탄의 명중률에 영향을 줄 수 있다. 이러한 요소는 명중확률 값과 표적의 탄착위치에 영향을 줄 수 있기 때문에, 신뢰성 있는 무기효과 데이터를 얻기 위해서는 이러한 요소들을 고려해야 한다. 본 연구는 신뢰성 있는 무기효과 데이터 계산을 위한 시나리오 설정을 위해 군사 시나리오 정의 언어인 MSDL(Military Scenario Definition Language)의 확장을 제안한다. 기존 MSDL의 요소 중 무기효과 데이터를 산출과 관리에 영향을 주는 요소인 시나리오 식별자(ScenarioID), 환경(Environment), 조직(Organizations), 그리고 설치(Installations)의 하위에 일부 요소를 추가하고, 해당 무기효과 데이터를 효율적으로 획득하기 위하여 적용하기 위하여 교전결과 처리 요소(DamageAssessment)와 실험계획 요소(DesignOfExperiments)를 추가하였다. 확장된 MSDL을 사용한 시뮬레이션 시나리오는 무기효과 데이터 산출을 위한 실험 시나리오 설정에서 교전에 영향을 주는 요소를 쉽게 반영할 수 있다. 확장된 MDSL은 무기체계 효과분석을 위한 실행환경인 AddSIM 4.0의 시나리오 설정 기능으로 반영되었으며, 이는 신뢰성 있는 무기효과 데이터 산출에 활용될 것이다.

자기공명영상진단기(磁氣共鳴影像診斷機)(MRI)의 보유현황(保有現況) 및 이용실태(利用實態)에 관한 조사연구(調査硏究) -부산시내(釜山市內) 3개(個) 병원(病院)을 중심(中心)으로- (A Study on the Status of Installation and Utilization of Magnetic Resonance Imaging in Korea)

  • 김경배;이만재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권2호
    • /
    • pp.37-47
    • /
    • 1992
  • Magnetic Resonance Imaging(MRI) is one of the most expensive and sophisticated diagnostic tool and has been hailed as the most exciting event in medical imaging "since the introduction of X-rays", but a major disadvantage, high cost, is coming into focus especially in our country. To determine the status of distribution of MR imagers in Korea and to serve as a basic material for an efficient utilization of this Imaging machine, a retrospective survey of nationwide and regional(3 hospitals in Pusan) installations was performed. The results were as follows : 1. As of April 30, 1991, a total of 33 MRI units(24 for superconducting, 6 for permanent and 3 for resistive units) were set up and operated. 91% of the units were distributed in big cities with no one installation in 7 provinces among 12 provinces in our country. 85% of the units were imported. 2. Although 42.4% of the units were operated in Seoul, Taejeon had the best condition for the distribution of this imaging machine per population, hospital, and bed in Korea. 3. In Pusan : a) 5 units were operated with all superconducting magnet and medium magnetic field in type of machine. b) 80.1 % of the examinations were central nervous system(CNS). c) MRI examination occupied 1.4% of all radiographic examinations and the patients referred from other hospitals were composed of 23.4%% of all patients. 4. The average days under operating of MRI unit a week in Puasn were higher(5.5) than that of Seoul(4.5), but the average number of examinations and hours a week and a day, respectively(33, 8.4), was less than that of Seoul(57, 12.9). 5. The patients with positive MRI findings in a hospital(B) in Pusan was 74.5% on an average.

  • PDF

고도처리장의 Bioindicator (Bioindicator in Advanced Wastewater Plants)

  • 이찬형;문경숙;진익렬
    • 한국미생물·생명공학회지
    • /
    • 제33권1호
    • /
    • pp.56-64
    • /
    • 2005
  • 고도처리장의 효율적 운영을 위해 원생동물의 분포를 조사하고 수질자료의 예측을 위한 bioindicator의 가능성을 분석하였다. 원생동물 종류별 개체수 분포는 출현빈도가 높으면 개체수도 많은 편으로 관찰되었다. Aspidisca, Trachelophyllum, Vorticella, Cinetochiluum, Oikomonas, Epistylis의 출현빈도는 $95\%$이상이었다. 처리장의 원생동물 분포는 유입수의 성상과 운영조건 차이 등이 세균의 증식에 영향을 미치고 변화된 세균분포에 적합하게 원생동물 분포가 이루어진다고 판단된다. 미생물분포와 통계결과는 처리장마다 다르므로 여러 처리장보다는 단일처리장에 적용되는 지표개발이 처리장의 효율적 운영에 기여할 수 있다. 요인분석결과 요인적재량의 형태와 요인의 해석이 유사하였다. 고도처리공법이 유사하고, 유입수의 성상이 비슷하여 처리장운영에 관여하는 요인이 비슷하게 나타난 것으로 판단된다. 상관분석과 회귀방정식을 이용함으로 처리장 수질변화를 미리 예상할 수 있다. 처리장의 원생동물 분포, 유출수질, 운영조건 자료들이 충분히 확보되면 원생동물 분포를 가지고 운영현황 및 가까운 미래의 수질예측이 가능해진다. 수질예측이 가능함으로 운영조건의 조기변동으로 처리수질을 양호하게 유지할 수 있다.

고도폐수처리장에서 원생동물을 이용한 수질예측 (Protozoa as an Indicator of Effluent Quality at Advanced Wastewater Treatment Plants)

  • 이찬형;문경숙;박상정;이은주;조재근;진익렬
    • 대한환경공학회지
    • /
    • 제28권4호
    • /
    • pp.389-396
    • /
    • 2006
  • 고도폐수처리장의 원생동물의 분포를 주별로 조사하였다. 통계방법을 이용하여 원생동물의 개체수와 운영조건, 유출수질을 분석하였다. 유입수의 성상과 처리장의 운영조건에 영향을 받아 처리장별로 원생동물 분포가 다르게 나타났다. 통계분석을 통해, 원생동물의 분포로 현재 운영중인 처리장의 운영조건을 알 수 있고 가까운 미래의 유출수질을 예측할 수 있었다. 처리장의 원생동물 분포, 유출수질, 운영조건 자료들이 충분히 확보되면 원생동물 관찰에 의해 처리장의 운영현황 및 가까운 미래의 수질예측이 가능해진다. 수질예측이 가능함으로 운영조건을 조기변동 하여 처리수질을 양호하게 유지할 수 있다. 장기적으로는 가장 좋은 유출수질때 나타나는 원생동물의 분포를 얻을 수 있도록 처리장의 운영조건을 변경함으로 좋은 유출수질을 얻을 수 있다.