• Title/Summary/Keyword: Installation criteria

Search Result 298, Processing Time 0.033 seconds

A Study on Establishment of Technical Guideline of the Installation and Operation for the Efficient Bio-gasification Facility of Fig Manure and Food Waste(I): (가축분뇨 병합처리 바이오가스화를 위한 설계 및 운전 기술지침 마련 연구(I): 현장조사 결과 중심으로)

  • Lee, Dongjin;Moon, HeeSung;Son, Jihwan;Bae, Jisu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.91-100
    • /
    • 2017
  • The purpose of this study is to provide a design and operation technical guideline for meeting the appropriate design criteria to bio-gasification facilities treating organic wastes. In accordance with the government's mid-to long-term policies on bio-gasification and energization of organic wastes, the expansion of the waste-to-energy (WTE) facilities is being remarkably promoted. However, because of the limitation of livestock manure containing low-concentration of volatile solids, there has been increased in combined bio-gasification without installing new anaerobic digestion facilities. The characteristics and common problems of each treatment processes were investigated for on-going 13 bio-gasification facilities. The seasonal precision monitoring of chemicophysics analysis on anaerobic digestor samples was conducted to provide guidelines for design and operation according to the progress of bio-gasification treatment. Consequently, major problems were investigated such as large deviation of organic materials depending on seasons, proper dehumidification of biogas and pretreatment of hydrogen sulfide.

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

Review of 2010 Major Medical Decisions (2010년 주요 의료 판결 분석)

  • Lee, Jung-Sun;Seo, Young-Hyun;Yoo, Hyun-Jung
    • The Korean Society of Law and Medicine
    • /
    • v.12 no.1
    • /
    • pp.177-225
    • /
    • 2011
  • Verdicts related to major medical litigation given by the Seoul Central District Court, the Seoul High Court and the Supreme Court in 2010 were analyzed. It's shown that in cases of the medical negligence regarding the occurrence of neonatal cerebral palsy, the plaintiff claims were dismissed using criteria proposed by associations of Obstetrics and Gynecology and Pediatrics in US, and thereof the burden of plaintiffs to prove the medical negligence has increased. In addition, in case of that the expected survival period of infants gets longer, payments for treatment and nursing after survival period determined by judges are made and it was judged to compensate it as a periodical indemnity. In case for the explanation obligation the most frequently mentioned in the medical litigation, in addition to cases of invoking the existing theory of explanation obligation, verdicts to mention the instructions of theory regarding instruction explanation obligation and the possibility of compensation for damages on property are given. Particularly, in cases for a liability of reparation by exaggerating the effects and not disclosing the risks related to treatment with stem cells, even if the treatment not approved by Food and Drug Administration is in violation of the Pharmaceutical Affairs Law, it's not illegal as violation in Pharmaceutical Affairs Law itself. But there is a certain verdict to present the possibility of an extension of the theory of explanation obligation by acknowledging the liability of reparation caused by illegal acts with no explanations of effects and risks of treatment with stem cell by doctors and pharmaceutical companies. In an incident in which a mental patient fell and died through the opened door of the roof at the hospital, a liability of reparation was acknowledged due to defects in structure installation management and this verdict drew an attention since the overall management responsibility about patients including structures was acknowledged to the hospital besides the obligations on medical practice. In case of the verdict without giving the opportunity to state the opinion with respect to the main legal issues, the responsibility of the court was emphasized since the court did not fulfill the explanation obligations. There were some cases in which payments for nursing and caring to a patient in vegetative state during the plastic surgery was admitted. However, in dental-related incidents, the proportion of cases in which plaintiff won was low since the difficulty of proving may be reflected. In the area of administrative litigation, unlike the existing position regarding arbitrary medical charge cover collected from patients in hospital, the verdict to admit the legitimacy of collection of medical treatment was given and attracted the attention of people. Verdict in which the expression related to medical advertisement was not exaggerated disposed the original verdict and pointed out the problem of excessive regulations on medical advertisement. The effort to analyze the trend of verdicts of court through reviewing the decisions and to organize should be continued, but the full decision should be disclosed as a base, and people and systems to enable the all time monitoring should be prepared.

  • PDF

A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers (성능위주설계자들의 화재실 범위 설정 방식에 따른 소요피난안전시간(RSET) 비교 및 오차산정에 관한 연구)

  • Baek, Sona;Choi, Jun-Ho;Hong, Won-Hwa;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • The Installation, Maintence, and Safety Control of Fire-fighting Systems Act of South Korea regulates that over 30-storey high-rise buildings including underground spaces should vitally perform the Performance-based Design to minimize property damage and personal injury as a fire risk assessment in advance. Therefore a PBD designer such as a fire safety professional engineer evaluate occupant's life safety by a scientific methodology. In order to evaluate the life safety, fire safety designers calculate the Required Safety Egress Time (RSET) which does not have the legal criteria regarding the standard method of calculation yet. So this way has been showing different results depending upon the designer's choice, knowledges and experiences. In this study, RSET calculation methods by six designers respectively were analysed from the thirteen reports of real performance based design projects conducted in Busan for a last five years. In particular, the Response Time calculation methods which have the most powerful effect for figuring the RSET are compared with the other designer's to deduce an error value.

A study on the Improvement of Design Guideline for the Use Enhancement of Privately Owned Public Space (공개공지(公開空地) 효용성(效用性) 제고(提高)를 위한 설계지침(設計指針) 개선(改善) 방안(方案))

  • Park, Jung-Lim;Kim, Hyun-Jun;Kwon, Young-Hyoo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.3
    • /
    • pp.115-141
    • /
    • 2011
  • In urban space, public space is publicly or privately owned space freely accessible by the public. Privately owned public space to the public hosts small-scale rest facilities to serve the public in buildings of certain purposes and sizes for the sake of pleasant urban environment. The Building Act and building ordinances formulate a set of criteria for management and easement of construction standards as well as the area. When creating privately owned public space, one can get incentives through the easement of floor space index and height limit. The purposes of this study were to investigate and analyze privately owned public open space, which is freely accessible by the public, and its adjacent streets and to propose plans to improve the regulations for securing privately owned public space for more rational and practical legal applications. The study then proposed some plans to help to increase the quality of privately owned public space including applying the coefficient to suggest the type of privately owned public space fit for the features of the streets and measure the appropriate utility level differently and distinguishing the mandatory items according to the facility regulations in privately owned public space from the ones qualified for additional points in case of installation. The types of privately owned public open space should be applied differently and the content of facilities intended should be different according to whether it will serve as a resting place or grant more importance on traffic by walking, depending on the features of its adjacent streets. The privately owned public space, the frontage space of building, and the adjacent sidewalks should become a whole and be regarded as one space from the integrated perspective. The results of the study claim further significance in that it investigated privately owned open space and roadside across Seoul. They will serve as useful data to solve the problems with the privately owned public space of the city, which destroys spatial continuity by focusing on the quantitative increase of privately owned open space and creating individual privately owned open spaces and builds high-rise buildings alienated from the existing spaces, and to increase the quality of future privately owned public space.

The Systematization of Waste Landfill Site Selection Process utilizing GIS (GIS를 활용한 쓰레기 매립지 입지 선정과정의 체계화 연구)

  • Han, Ji Youn
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.21-30
    • /
    • 2014
  • Waste landfill site which is the facility usually rejected by communities is generally perceived as one of the serious social problems. It causes serious conflicts between interested parties from the beginning of the site selection process and produces various difficulties throughout the installation process. This study suggests the systematization and standardization of the landfill site selection process to reduce those problems and to objectify the process. The study process and results are as follows. First, the landfill site selection process was divided into 4 general phases rather than more specific fragmented phases and the requirements for each phase were suggested accordingly. This can make the process clearly organized and bring the standardization of the process by increasing the applicability of each phase for various situations. Second, the utilization of GIS(Geographic Information System) and PAPRIKA (Potentially All Pairwise RanKings of all possible Alternatives) among the various MCDA(Multi-Criteria Decision Analysis) methods was suggested as the objective and scientific method. Third, the hypothetical case study on the landfill site selection process of Cheongju city was conducted based on the information above and the results show the practicability and objectivity of the newly defined landfill site selection process in this study.

A study on taxation of foreign corporation's Permanent Establishment (고정사업장의 과세에 관한 연구: 플랜트 건설.판매기업의 사례를 중심으로)

  • Suh, Jung-Rog
    • Management & Information Systems Review
    • /
    • v.29 no.3
    • /
    • pp.71-96
    • /
    • 2010
  • This article firstly reviewed Permanent Established(PE) concept of OECD and UN model tax treaty and compared it with that of Korean Corporate Income Tax Law(CITL). The various factors regarding profit like ways of deciding the local source profit, scope and calculation method which will be imputed to PE were also reviewed. Based on above, standard PE judgement basis and calculation method of local source profit were also studied by using actual cases in foreign corporation which performs plant construction & sales in Korea. Accordingly to properly solve the conflict regarding international tax and to protect the tax authority against the foreign corporation in Korea, by standing on equality, I now propose followings for the better concept of PE in Korea. Firstly, the article that a building site or construction or installation project constitutes a PE only if it lasts more than 6 months should be modified to reflect OECD model convention's criteria of 12 months. Second, the scope of 'subordinate attorney' which is regarded as PE under CITL is now including 'holding-delivery attorney', 'order attorney', and 'assurance attorney' as well as 'contract attorney'. This is overly limit the activities of foreign corporation. It had better be loosened only to include 'contract attorney' as OECD provisions. Third, the CITL limits the cases of preparatory and/or auxiliary place which is not regarded as PE, thus limit the foreign corporations' business by expanding the concept of PE. This had better be eased. Fourth, in deciding the amount of local source profits, the CITL stipulates to split the profits by the relevant contribution of transaction parties through 'profit split method'. To solve the conflict, the ways of profit split must be better clarified through providing object and detailed standard and basis.

  • PDF

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power Generation and Stream - Results of the Field Investigation (바이오가스 이용 기술지침 마련을 위한 연구(I) - 현장조사 결과 중심으로)

  • Moon, HeeSung;Bae, Jisu;Park, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.55-64
    • /
    • 2018
  • The purpose of this study is to provide a design and operation technical guideline for meeting the appropriate design criteria to biogas utilization treating organic wastes. In accordance with the government's mid-to long-term policies on bio-gasification and energization of organic wastes, the expansion of the waste-to-energy (WTE) facilities is being remarkably promoted. However, because of the limitation of livestock manure containing low-concentration of volatile solids, there has been increased in combined bio-gasification without installing new anaerobic digestion facilities. The characteristics and common problems of each treatment processes were investigated for on-going 11 bio-gasification facilities. The seasonal precision monitoring of chemicophysics analysis on anaerobic digestor samples was conducted to provide guidelines for design and operation according to the progress of biogas utilization. Consequently, Major problems were investigated such as large deviation of organic materials depending on seasons, proper dehumidification of biogas, pretreatment of hydrogen sulfide, operation of power generation and steam. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure), research the facilities problem through field investigation.

A Quantitative Risk Analysis of Related to Tower Crane Using the FMEA (타워크레인의 정량적 위험성 평가가법에 관한 연구(FMEA 기법 위주))

  • Shim, Kyu-Hyung;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.34-39
    • /
    • 2010
  • The purpose of this study is to suggest objective evaluation model as a plan to utilize as opportunity in establishing judgment standard of mutual inspection criteria and to upgrade inspection ability by reviewing and analyzing level of danger and importance in advance based on inspection results of inspection institutions regarding tower cranes used in construction fields. Tower crane is a mechanical device transporting construction supplies and heavy materials to places over 20~150M high from the ground for the period ranging from a short time of 2~3 months to two years after being installed in construction sites in vicinity of buildings or structures and is an important facility indispensable for construction sites. However, since use period after installation is short and professional technical ability of technicians working on-site about of tower crane is poor, systematic and quantitative safety management is not carried out As a part of researches on procedure of RBI(Risk Based Inspection) possible to apply to Knowledge Based System based on knowledge and experiences of experts as well as to tower cranes for solving these problems, quantitative RPN(Risk Priority Number) was applied to RPN utilizing technique of FMEA(Failure Mode and Effect Analyses). When general RBI 80/20 Rule was applied parts with high level of risks were found out as wire rope, hoist up/down safety device, reduction gear, and etc. However, since there are still many insufficient parts as risk analyses of tower crane were not established, it is necessary for experts with sufficient experiences and knowledge to supplement active RBI techniques and continuous researches on tower cranes by sharing and setting up data base of important information with this study as a starting point.

Structural Capacity Evaluation of System Scaffolding using X-Type Advanced Guardrail (교차가새형 선행 안전난간을 적용한 시스템비계의 구조 성능 평가)

  • Park, J.D.;Lee, H.S.;Shin, W.S.;Kwon, Y.J.;Park, S.E.;Yang, S.S.;Jung, K.
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.49-58
    • /
    • 2020
  • In domestic construction sites, when installing steel pipe scaffolding and system scaffolding, the guardrails are installed after the installation of the work platforms. This conventional guardrail system (CGS) is always exposed to the risk of falls because the safety railing is installed later. In order to prevent fall disasters during erecting and dismantling scaffolds, it is necessary to introduce the advanced guardrail system (AGS) which installs railings in advance of climbing onto a work platform. For the introduction of the AGS, the structural performance of the system scaffolding applying the CGS and the AGS was compared and evaluated. The structural analysis of the system scaffold (height: 31 m and width: 27.4 m) with AGS confirmed that structural safety was ensured because the maximum stress of each element of the system scaffolding satisfies the allowable stress of each element. As a result of performance comparison of CGS and AGS for each element, the combined stress ratio of vertical posts in AGS was 6.4% lower than that of CGS. In addition, in the case of ledger and transom, the combined stress ratios of AGS and CGS were almost the same. The compression test of the assembled system scaffolding (three-storied, 1 bay) showed that the AGS had better performance than the CGS by 9.7% (8.91 kN). The cross bracing exceeds the limit on slenderness ratio of codes for structural steel design. But the safety factor for the compressive load of the cross bracing was evaluated as meeting the design criteria by securing 3 or more. In actual experiments, it was confirmed that brace buckling did not occur even though the overall scaffold was buckled. Therefore, in the case of temporary structures, it was proposed to revise the standards for limiting on slenderness ratio of secondary or auxiliary elements to recommendations. This study can be used as basic data for the introduction of AGS for installing guardrails in advance at domestic construction sites.