• 제목/요약/키워드: Installation

검색결과 12,517건 처리시간 0.032초

해양설비용 정밀 모니터링 센서의 개발 및 특성 분석 (The Development and Characteristics Analysis of High Precision Monitoring Sensor for the Marine Installation)

  • 조정환;고성원
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.101-106
    • /
    • 2013
  • This paper proposes the new high precision monitoring sensor for the Marine Installation. Among variety of sensor network systems, wireless information transmission through the marine is one of the enabling technologies for the development of future marine-observation systems and sensor networks. Applications of marine monitoring range from oil industry to aquaculture, and include instrument monitoring, pollution control, climate recording, prediction of natural disturbances. For these marine applications to be available, however, the provision of precise location information using monitoring sensor is essential. In this paper, the dynamic characteristics for obtaining the location information of monitoring sensor is analyzed. The theoretical and experimental studies have been carried out. The presented results from the above investigation show considerably excellent performance for the Monitoring for the Marine Installation.

케이블 포설장력 특성에 대한 실험적 고찰 (The experimental investigation on the characteristics of the cabling tension)

  • 김동훈;한진우
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.49-53
    • /
    • 2009
  • If you are installing communications cables in the pipeline based on the kind of cable installation tension within the allowed range of the tension must be maintained. The tension of the installation affected by the cable types, cable jacketed status, cross-sectional shape of the pipeline, the substance present in the pipeline, pipeline linear, the direction of the cable is installed. Depending on the size of the cable installation tension fatal influence on the quality of communication, or, at worst, the cable can be cut. In this paper, test bed for building a pipeline and using optical cable and such cable tension was measured. Freedom of access to the pipeline used in the experiment, and installed in conjunction with the cable tension was measured. It possible for the cable installation to determine whether a duplicate, and have compared the actual measured tension value and the theoretical expression.

  • PDF

무인신호위반단속장비 설치에 따른 사고감소효과 예측 (Prediction on the Accident Reduction Effects of the Red Light Cameras Installation)

  • 김태영;백태헌;박병호
    • 한국도로학회논문집
    • /
    • 제14권6호
    • /
    • pp.67-73
    • /
    • 2012
  • PURPOSES : This study deals with the effects on the installation of RLC(Red Light Camera). The objective is to analyze the effects of accident reduction after the installation of RLC. METHODS : In pursuing the above, the study uses the 703 accident data occurred at the 64 intersections which RLC are installed or not installed. RESULTS : The main results are as follows. First, Poisson RLC accident model developed in this study is analyzed to be statistically significant. Second, using the above developed model, 33 intersections among 40 intersections are predicted to have the decreasing effects of accidents after the installation of RLC. Finally, the reduction effects are analyzed to be affected by ADT and the number of left-turn lane. CONCLUSIONS : This study is expected to improve the efficiency of RLC and to help in decision-making of RLC installation.

입도에 따른 지오그리드의 시공손상계수 산정 (Evaluation of Installation Damage Factor for Geogrid with Particle Size)

  • 임성윤;송창섭
    • 한국농공학회논문집
    • /
    • 제52권3호
    • /
    • pp.113-120
    • /
    • 2010
  • Reduction factor for installation damage required to calculate design strength of geogrid used in MSEW(mechanically stabilized earth wall) design is usually obtained in the field test simulating real construction condition. However, damages occurred in geogrid during backfill work are influenced by many factors such as polymer types, unit weight per area, backfill construction method and gradation of backfill material and field test considering these factors demand lots of time and costs. In this study, factors affecting installation damage are analyzed and empirical method to evaluate reduction factor for installation damage using maximum particle size in backfill material is suggested.

Long-Term Performance of Geosynthetic Reinforcement Materials with Field Installation Condition

  • Jeon, Han-Yong;Mok, Mun-Sung;Cho, Seong-Ho;Byun, Sung-Weon;Lee, Joon-Seok
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.305-306
    • /
    • 2003
  • In the case of the geosynthetics usage to soil structure, there are some damages by compaction. And these damages by the installation compaction result in the unexpected changes of short and long term properties of the structure. So in the case of index test, there are some problems to the exact evaluation on the installation damage. Therefore, to the more definite evaluation on the installation damage of geosynthetics, the real site installation damage test is encouraged. (omitted)

  • PDF

철도노반 보강용 지오그리드의 크리프 및 손상이 장기 인장강도에 미치는 영향평가 (Assessments of the Combined Effect of Installation Damage and Creep on the Long-Term Design Strength of Geogrid for Railroad Reinforcement)

  • 이도희;박태순;조삼덕;이광우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1156-1161
    • /
    • 2004
  • The factors affecting the long-term design strength of geogrid for railroad reinforcement can be classified into factors on creep deformation, installation damage, temperature, chemical degradation, biological degradation. Especially, creep deformation and installation damage are considered as main factors to determine the long-term design strength of geogrid. This paper describes the results of a series of experimental study, which are carried out to assess the combined effect of installation damage and creep deformation for the long-term design strength of geogrid reinforcement. In this study, a series of field tests are carried out to assess installation damage of a various geogrids according to different fill materials, and then creep tests are conducted to assess the creep properties of both undamaged and damaged geogrids.

  • PDF

전기설비 취약지역에서의 분진에 의한 사고영향 분석 (The Accident Analysis Caused by Dust of Electrical Installation in Vulnerable Area)

  • 김영석;송길목;김종민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.345-348
    • /
    • 2008
  • In this paper, we investigated a dust pollution and spot survey of electrical installation in vulnerable area. From the survey results, we know that the dust was easily accumulated in cabinet panel because the cabinet panel cover was opened and the management of installation was not good. Although the dust pollution was not difference, the possibility of accident become increased by dust in salt area. Thus, it is necessary to variation of cabinet panel shape to prevention of electrical disaster in dust occurrence and another protection devices.

  • PDF

지중송전선로 병행지선 최적 설치 방안에 관한 연구 (A Study on Optimal Installation Method of Earth Continuity Conductor on Underground Power Cable Systems)

  • 정채균;강지원;윤종건;김양상
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1689-1694
    • /
    • 2009
  • In a previous paper, the characteristics of ECC (earth continuity conductor) have been analysed for reducing the level of induced sheath voltage considering the dimension and position of ECC, the spacing between ECC and three phase cables, and the use of two ECC conductors at the single point boned section of underground power cable system. From these results, the study conditions for optimal installation has been selected such as installation section, conductor size and etc. In this paper, 5 cases which are set by possible installation conditions are tested based on previous research results. Finally, the optimal installation method of ECC is selected on underground power cable systems.

유원시설 전기설비 설치에 대한 국내외 규정 비교 분석 (Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride)

  • 김기현;김종민;김한상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

지하구내 수.변전설비 안전실태 조사 (A Research on the Safety Condition of Power Utilities Installed on Underground Premises)

  • 정종욱;정진수;이건호;김영석;배석명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.410-413
    • /
    • 2006
  • This paper describes the safety condition of power utilities installed on underground premises when flooding occurs. As advance preparations, the statistical data were investigated based on the rainfall trend; the flooding damage; the power utilities installation; the electric shock accidents, and domestic md foreign regulations pertaining to the power utilities installation on underground premises were also compared and analyzed. After the preliminaries, the safety condition of underground power utilities was inspected at site and the results were reflected on considering countermeasures. Based on the further studies, the regulations closely related to the underground power utilities installation can be modified.

  • PDF