Numerical Analysis on the Flow Characteristics Considering the Inspiratory Flow Rate in a Human Airway (수치해석 기법을 이용한 호흡 유량에 따른 사람의 기도 내 유동 특성 연구)

  • Sung, Kun Hyuk;Ryou, Hong Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.177-183
    • /
    • 2012
  • The inspiratory flow rate of a human is changed with the amount of the workload. The flow characteristic is affected by the inspiratory flow rate. In the flow field of airway, the both of turbulence intensity and secondary flow affect the deposition pattern of particles which is important for the drug-aerosol targeting. Thus the analysis of the flow characteristic in a human airway is important. The purpose of this study is to investigate the effects of the inspiratory flow rate on the flow characteristics in a human airway. The tubular airway is consistent with the oral cavity, pharynx, larynx and trachea. The relatively inspiratory flow rate is used at each case of human states regarding the workload. By the effect of geometric airway changes, transition to turbulent airflow after the larynx can occur with relaminarization further downstream. The low Reynolds number k-${\omega}$ turbulence model is used for analysis with flow regime. As the inspiratory flow rate is larger, the turbulence kinetic energy and secondary flow intensity increase in airway. On the other hand, the area of recirculation zone is smaller.

The Effect of Twenties Female Caffeine Addiction on Cardiorespiratory Capacity (카페인 중독이 20대 성인 여성의 심장호흡기계능력에 미치는 영향)

  • Yoon, Young-Jeoi
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.8
    • /
    • pp.197-202
    • /
    • 2020
  • In this study, we investigate the effect of twenties female caffeine addiction on cardiorespiratory capacity. For this study, we divided 35 female students at H university into caffeine addict group(n=17) and none caffeine addict group(n=18). Measure maximal oxygen uptake, maximal energy consumption and METs using Cycle Ergometer to assess cardiac capacity. Measure peak inspiratory pressure, peak inspiratory flow rate, peak inspiratory capacity, average inspiratory pressure, average inspiratory flow rate, average inspiratory capacity using Power Breathe K5 to assess respiratory capacity. As a result, cardiac capacity showed a statistically significant decrease in maximal oxgen uptake and METs compared caffeine addict group to none caffeine addict group(p<.001). respiratory capacity showed a statistically significant decrease in peak inspiratory pressure(p<.05), peak inspiratory flow rate(p<.01), average inspiratory pressure(p<.01), average inspiratory flow rate(p<.01), compared caffeine addict group to none caffeine addict group. Combining the results of the study, we could see that caffeine addiction reduces the cardiorespiratory capacity in twenties female. Therefore, it could be used as a basis date to prevent caffeine addiction for twenties female.

The Immediate Effect of Inspiratory Muscle Training with Whole Body Vibration on Pulmonary Function of Stroke Patients (전신진동이 결합된 흡기근 훈련이 뇌졸중 환자의 폐 기능에 미치는 즉각적인 효과)

  • Park, Si-Hyun;Seo, Dong-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.4
    • /
    • pp.29-37
    • /
    • 2017
  • PURPOSE: This study investigated the immediate effect of inspiratory muscle training with whole-body vibration on the pulmonary function of subacute stroke patients. METHODS: All participants (n=30) were allocated to the following groups: (1) the inspiratory muscle training group with whole-body vibration (n=10), wherein the patients received inspiratory muscle training with whole-body vibration comprising 3minutes of vibration per session and respiratory training of 30 times and 2 sessions for one day. (2) the inspiratory muscle training group with visual feedback (n=10), wherein the patients received inspiratory muscle training with visual feedback. (3) the inspiratory muscle training group (n=10), wherein the patients received inspiratory muscle training. RESULTS: After the experiment, the inspiratory muscle training group with whole-body vibration exhibited significantly higher forced vital capacity, forced expiratory volume at 1 second, peak inspiratory flow rate, maximal inspiratory pressure, and chest expansion (p<.05), compared to the other groups. Inspiratory muscle training group with whole-body vibration had significantly higher peak expiratory flow rate and maximal voluntary ventilation than the other groups (p<.05). CONCLUSION: These results show that pulmonary function, maximal inspiratory pressure, and chest expansion were significantly better in the inspiratory muscle training group with whole-body vibration than in the other groups. Thus, this treatment will help recovery of pulmonary function in stroke patients.

Inspiratory Muscle Strengthening Training Method to Improve Respiratory Function : Comparison of the Effects of Diaphragmatic Breathing with Upper Arm Exercise and Power-Breathe Breathing (호흡 기능 향상을 위한 들숨근 강화 훈련 방법 : 위팔운동을 동반한 가로막 호흡과 파워브리드 호흡의 효과 비교)

  • Lee, Keon-Cheol;Choo, Yeon-Ki
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Purpose : It was to compare changes in respiratory function (pulmonary function, inspiratory function) after four weeks of inspiratory muscle strengthening training (diaphragmatic breathing with upper arm exercise, Power-Breathe breathing) for 36 healthy people. Methods : Subjects were randomly assigned to diaphragmatic breathing with upper arm exercise (Group I) and Power-breathe breathing (Group II) was conducted by the protocol for four weeks five times per week. As the main measurement method for comparison between groups For pulmonary function, Forced Vital Capacity (FVC) and Forced Expiratory Volume at One second (FEV1) were used, and for inspiratory function, Maximum Inspiratory Capacity (MIC), Maximum Inspiratory Pressure (MIP), and Maximum Inspiratory Flow Rate (MIFR) were used. Results : In changes in pulmonary function between groups, FVC and FEV1 showed no significant difference, and in inspiratory function changes, MIC showed no significant difference, but in MIP and MIFR, Group B significantly improved over Group A. Conclusion : The progressive resistance training using the Power-breath device applied to the inspiratory muscle did not show a significant difference in the increase in the amount of air in the lungs and chest cage compared to the diaphragmatic breathing training accompanied by the upper arm exercise. However, by increasing the air inflow rate and pressure, it showed a more excellent effect on improving respiratory function.

The effect of resistance inspiratory muscle training on respiratory function in stroke (저항성 들숨근 훈련이 뇌졸중 환자의 호흡기능에 미치는 영향)

  • Lee, So Yun;Han, Jin Tae
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.3
    • /
    • pp.1-11
    • /
    • 2020
  • Background: The purpose of this study was to investigated the effects of threshold resistance inspiratory muscle training on respiratory function in chronic stroke patients. Design: Randomized Controlled Trial Methods: Eighteen patient with stroke were randomly assigned to the experimental group (n=9) and control group (n=9) all testing and training. The experimental group underwent threshold resistance inspiratory muscle training with resistance adjusted of maximal inspiratory pressure, 60 breathing a day and general physical therapy 30 minutes a day, 5 times a week for 4 weeks. The control group was taken general respiratory muscle training and general physical therapy for 4 weeks in the same way. Respiratory function, walking ability were evaluated before and after the intervention. Statistical significance of the results were evaluated by ANCOVA between control group and experimental group after intervention. Results: There was a significant increase in FVC and FEV1 in the experimental group in pulmonary function tests (p<0.05). There was a significant difference with the maximum inspiratory pressure and the maximum inspiratory flow rate between experimental and control group (p<0.05). There was no significant difference with the maximum inspiratory capacity between experimental and control group (p>0.05) but the maximum inspiratory capacity of experimental group some increased than that of control group. Conclusion: These finding gave some indications that the threshold resistance inspiratory training may benefit on pulmonary function in people with stroke, and it is feasible to be included in rehabilitation interventions with this population.

Analysis of correlation between the inspiratory capacity of the National softball players and the bone density, bon mass, muscle power, muscle endurance (국가대표 소프트볼선수들의 흡기능력과 골밀도 및 골 질량 그리고 체간의 근력 및 근지구력의 상관관계 분석)

  • Kim, Hyun Chul;Park, Ki Jun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.1
    • /
    • pp.95-104
    • /
    • 2020
  • PURPOSE: A prospective study was conducted to investigate the correlation between the inspiration ability, bone mineral density, lumbar muscle strength, and muscular endurance for the national softball athletes in the national training center. METHODS: The general characteristics of study subjects, inspiration ability, bone mineral density, muscle strength, and muscular endurance data were analyzed using descriptive statistics. In addition, the Pearson product moment correlation was performed to investigate the correlation between the inspiratory capacity, bone mineral density, muscle strength, and muscular endurance. RESULTS: The inspiration, flow rates, and volume were not correlated with the bone mass and bone mineral density. Inspiration and the flow rates and volume were not correlated with the bone mass and bone mineral density. On the other hand, inspiration was correlated with the Extensor muscles (r=.464, p=.006) at an angular velocity of 60°/s and the flexors (r=.463, p=.006) and extensor muscles (r=.615, p<.001) at an angular velocity of 180°/s. The flow rate was also correlated with the extensor muscles (r=.444, p=.009) at an angular velocity of 60°/s and with flexor muscles (r=.432, p=.011) and extensor muscles (r=.589, p<.001) at an angular velocity of 180°/s. Finally, the volume was correlated at the extensor muscles at an angular velocity of 180°/s (r=.534, p=.001). CONCLUSION: The correlation between the inspiratory capacity, bone mineral density, muscle strength, and muscular endurance of softball athletes did not correlate with the bone mass and bone density. On the other hand, the lumbar muscle strength increased with increasing inspiratory capacity.

Inspiratory Flow Rate for the Evaluation of Bronchodilator in Patients with COPD (만성폐쇄성폐질환 환자에서 기관지확장제 흡입에 대한 흡기환기지표의 반응)

  • Baik, Jae-Joong;Park, Keon-Uk;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.342-350
    • /
    • 1995
  • Background: Although there are improvements of clinical symtoms after bronchodilator inhalation in COPD patients, it has been noted that there was no increase of $FEV_1$ in some cases. $FEV_1$ did not reflect precisely the improvement of ventilatory mechanics after bronchodilator inhalation in these COPD patients. The main pathophysiology of COPD is obstruction of airway in expiratory phase but in result, the load of respiratory system is increased in inspiratory phase. Therefore the improvement of clinical symptoms after bronchodilator inhalation may be due to the decrease of inspiratory load. So we performed the study which investigated the effect of bronchodilator on inspiratory response of vetilatory mechanics in COPD patients. Methods: In 17 stable COPD patients, inspiratory and expiratory forced flow-volume curves were measured respectively before bronchodilator inhalation. 10mg of salbutamol solution was inhaled via jet nebulizer for 4 minutes. Forced expiratory and inspiratory flow-volume curves were measured again 15 minutes after bronchodilator inhalation. Results: $FEV_1$, FVC and $FEV_1$/FVC% were $0.92{\pm}0.34L$($38.3{\pm}14.9%$ predicted), $2.5{\pm}0.81L$($71.1{\pm}21.0%$ predicted) and $43.1{\pm}14.5%$ respectively before bronchodilator inhalation. The values of increase of $FEV_1$, FVC and PIF(Peak Inspiratory Flow) were $0.15{\pm}0.13L$(relative increase: 17.0%), $0.58{\pm}0.38\;L$(29.0%) and $1.0{\pm}0.56L$/sec(37.5%) respectively after bronchodilator inhalation. The increase of PIF was twice more than $FEV_1$ in average(p<0.001). The increase of PIF in these patients whose $FEV_1$ was not increased after bronchodilator inhalation were 35.0%, 44.0% and 55.5% respectively. Conclusion: The inspiratory parameter reflected improvement of ventilatory mechanics by inhaled bronchodilater better than expiratory parameters in COPD patients.

  • PDF

Determination of Minimal Pressure Support Level During Weaning from Pressure Support Ventilation (압력보조 환기법으로 기계호흡 이탈시 최소압력보조(Minimal Pressure Support) 수준의 결정)

  • Jung, Bock-Hyun;Koh, Youn-Suck;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.380-387
    • /
    • 1998
  • Background: Minimal pressure support(PSmin) is a level of pressure support which offset the imposed work of breathing(WOBimp) developed by endotracheal tube and ventilator circuits in pressure support ventilation While the lower applied level of pressure support compared to PSmin could induce respiratory muscle fatigue, the higher level than PSmin could keep respiratory muscle rest resulting in prolongation of weaning period during weaning from mechanical ventilation PSmin has been usually applied in the level of 5~10 cm$H_2O$, but the accurate level of PSmin is difficult to be determinated in individual cases. PSmin is known to be calculated by using the equation of "PSmin = peak inspiratory flow rate during spontaneus ventilation$\times$total ventilatory system resistance", but correlation of calculated PSmin and measured PSmin has not been known. The objects of this study were firstly to assess whether customarily applied pressure support level of 5~10 cm$H_2O$ would be appropriate to offset the imposed work of breathing among the patients under weaning process, and secondly to estimate the correlation between the measured PSmin and calculated PSmin. Method : 1) Measurement of PSmin : Intratracheal pressure changes were measured through Hi-Lo jet tracheal tube (8mm in diameter, Mallinckroft, USA) by using pulmonary monitor(CP-100 pulmonary monitor, Bicore, USA), and then pressure support level of mechanical ventilator were increased until WOBimp was reached to 0.01 J/L or less. Measured PSmin was defined as the lowest pressure to make WOBimp 0.01 J/L or less. 2) Calculation of PSmin : Peak airway pressure(Ppeak), plateau airway pressure(Pplat) and mean inspiratory flow rate of the subjects were measured on volume control mode of mechanical ventilation after sedation. Spontaneous peak inspiratory flow rates were measured on CPAP mode(O cm$H_2O$). Thereafter PSmin was calculated by using the equation "PSmin = peak inspiratory flow rate$\times$R, R = (Ppeak-Pplat)/mean inspiratory flow rate during volume control mode on mechanical ventilation". Results: Sixteen patients who were considered as the candidate for weaning from mechanical ventilation were included in the study. Mean age was 64(${\pm}14$) years, and the mean of total ventilation times was 9(${\pm}4$) days. All patients except one were males. The measured PSmin of the subjects ranged 4.0~12.5cm$H_2O$ in 14 patients. The mean level of PSmin was 7.6(${\pm}2.5\;cmH_2O$) in measured PSmin, 8.6 (${\pm}3.25\;cmH_2O$) in calculated PSmin Correlation between the measured PSmin and the calculated PSmin is significantly high(n=9, r=0.88, p=0.002). The calculated PSmin show a tendancy to be higher than the corresponding measured PSmin in 8 out of 9 subjects(p=0.09). The ratio of measured PSmin/calculated PSmin was 0.81(${\pm}0.05$). Conclusion: Minimal pressure support levels were different in individual cases in the range from 4 to 12.5 cm$H_2O$. Because the equation-driven calculated PSmin showed a good correlation with measured PSmin, the application of equation-driven PSmin would be then appropriate compared with conventional application of 5~10 cm$H_2O$ in patients under difficult weaning process with pressure support ventilation.

  • PDF

The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP (Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과)

  • Chin, Jae-Yong;Lim, Chae-Man;Koh, Youn-Suck;Park, Pyung-Whan;Choi, Jong-Moo;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.201-209
    • /
    • 1996
  • Background : Auto-PEEP which develops when expiratory lung emptying is not finished until the beginning of next inspiration is frequently found in patients on mechanical ventilation. Its presence imposes increased risk of barotrauma and hypotension, as well as increased work of breathing (WOB) by adding inspiratory threshold load and/or adversely affecting to inspiratory trigger sensitivity. The aim of this study is to evaluate the relationship of auto-PEEP with WOB and to evaluate the effect of PEEP applied by ventilator (external PEEP) on WOB in patients with auto-PEEP. Method : 15 patients, who required mechanical ventilation for management of acute respiratory failure, were studied. First, the differences in WOB and other indices of respiratory mechanics were examined between 7 patients with auto-PEEP and 8 patients without auto-PEEP. Then, we applied the 3 cm $H_2O$ of external PEEP to patients with auto-PEEP and evaluated its effects on lung mechanics as well as WOB. Indices of respiratory mechanics including tidal volume ($V_T$), repiratory rate, minute ventilation ($V_E$), peak inspiratory flow rate (PIFR), peak expiratory flow rate (PEFR), peak inspiratory pressure (PIP), $T_I/T_{TOT}$, auto-PEEP, dynamic compliance of lung (Cdyn), expiratory airway resistance (RAWe), mean airway resistance (RAWm), $p_{0.1}$, work of breathing performed by patient (WOB), and pressure-time product (PTP) were obtained by CP-100 Pulmonary Monitor (Bicore, USA). The values were expressed as mean $\pm$ SEM (standard error of mean). Results : 1) Comparison of WOB and other indices of respiratory mechanics in patients with and without auto-PEEP : There was significant increase in WOB ($l.71{\pm}0.24$ vs $0.50{\pm}0.19\;J/L$, p=0.007), PTP ($317{\pm}70$ vs $98{\pm}36\;cm$ $H_2O{\cdot}sec/min$, p=0.023), RAWe ($35.6{\pm}5.7$ vs $18.2{\pm}2.3\;cm$ H2O/L/sec, p=0.023), RAWm ($28.8{\pm}2.5$ vs $11.9{\pm}2.0cm$ H2O/L/sec, p=0.001) and $P_{0.1}$ ($6.2{\pm}1.0$ vs 2.9+0.6 cm H2O, p=0.021) in patients with auto-PEEP compared to patients without auto-PEEP. The differences of other indices including $V_T$, PEFR, $V_E$ and $T_I/T_{TOT}$ showed no significance. 2) Effect of 3 cm $H_2O$ external PEEP on respiratory mechanics in patients with auto-PEEP : When 3 cm $H_2O$ of external PEEP was applied, there were significant decrease in WOB ($1.71{\pm}0.24$ vs $1.20{\pm}0.21\;J/L$, p=0.021) and PTP ($317{\pm}70$ vs $231{\pm}55\;cm$ $H_2O{\cdot}sec/min$, p=0.038). RAWm showed a tendency to decrease ($28.8{\pm}2.5$ vs $23.9{\pm}2.1\;cm$ $H_2O$, p=0.051). But PIP was increased with application of 3 cm $H_2O$ of external PEEP ($16{\pm}2$ vs $22{\pm}3\;cm$ $H_2O$, p=0.008). $V_T$, $V_E$, PEFR, $T_I/T_{TOT}$ and Cdyn did not change significantly. Conclusion : The presence of auto-PEEP in mechanically ventilated patients was accompanied with increased WOB performed by patient, and this WOB was decreased by 3 cm $H_2O$ of externally applied PEEP. But, with 3 cm $H_2O$ of external PEEP, increased PIP was noted, implying the importance of close monitoring of the airway pressure during application of external PEEP.

  • PDF

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.