• Title/Summary/Keyword: Inspection reliability

Search Result 620, Processing Time 0.025 seconds

A Study on the Impact of Forklift Institutional, Technical, and Educational Factors on a Disaster Reduction (지게차의 제도적, 기술적, 교육적 요인이 재해감소에 미치는 영향에 관한 연구)

  • Young Min Park;Jin Eog Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.770-778
    • /
    • 2023
  • Purpose: In order to reduce forklift industrial accidents, it is necessary to classify them into institutional, technical, and educational factors and conduct research on whether each factor affects disaster reduction. Method: Descriptive statistical analysis, validity analysis, reliability analysis, and multiple regression analysis were conducted using SPSS 18 program based on an offline questionnaire based on a 5-point Likert scale. Result: As a result of multiple regression analysis, it was found that institutional, technical, and educational factors, which are independent variables for disaster reduction, explain about 62.5% of the variance in disaster prevention, which is the dependent variable. The regression model verification was found to be statistically significant with F=118.775 and significance probability p<0.01. Conclusion: First, there is a need to prevent disasters by including electric forklifts weighing less than 3 tons in the inspection system. Second, there is a need to make it mandatory to install front and rear cameras and forklift line beams to prevent forklift collision disasters. Third, there is a need to conduct special training related to forklifts every year, and drivers and nearby workers need to be included in the special training for forklifts.

Evaluation of Harmless Crack Size of SCM822H Steel by Double Shot Peening (이중 쇼트 피닝에 의한 SCM822H 강의 무해화 균열 크기 평가)

  • Jin-Woo Choi;Seo-Hyun Yun;Yung-Kug Kwon;Gum-Hwa Lee;Ki-Woo, Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1011-1017
    • /
    • 2023
  • In this study, the harmless crack size (ahml) by double shot peening (DSP) using shot balls with different diameters was evaluated on carburized, quenched-tempered SCM822H steel. The minimum crack size (aNDI) detectable by non-destructive inspection was also evaluated. The relationship between the crack size (a25,50) that reduces the fatigue limit by 25% and 50% and ahml was evaluated. The residual stress of DSP was greater in SP(0.6+0.08) than SP(0.8+0.08) and appeared deeper in the depth direction. In addition, the hardness below the surface appeared larger. The fatigue limit of DSP increased 2.07 times and 1.95 times compared to non-SP. All ahml of the DSP specimen was determined at the depth (a). The compressive residual stress distribution affects ahml, and the ahml of SP(0.6+0.08), which has a large compressive residual stress and a high fatigue limit, appeared large. ahml of SP(0.6+0.08) introduced deeper than the residual stress of SP(0.8+0.08) is larger in the range of As=1.0-0.3. Since the residual stress in the thickness direction has a greater effect on ahml than the residual stress at the surface, it is necessary to introduce it more deeply. The relation of ahml, a25,50, and aNDI were evaluated in the point for safety and reliability.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

Reducing error rates in general nuclear medicine imaging to increase patient satisfaction (핵의학 일반영상 검사업무 오류개선 활동에 따른 환자 만족도)

  • Kim, Ho-Sung;Im, In-Chul;Park, Cheol-Woo;Lim, Jong-Duek;Kim, Sun-Geun;Lee, Jae-Seung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.295-302
    • /
    • 2011
  • To n the field of nuclear medicine, with regard to checking regular patients, from the moment they register up to the doctor's diagnosis, the person in charge of the checks can find errors in the diagnosis, reexamine, reanalyze the results or save images to PACS. Through this process, the results obtained from the readings are delayed due to checks and additional tests which occur in hospitals, causing patient satisfaction and affected reliability. Accordingly, the purpose is to include visual inspection of the results to minimize error, improve efficiency and increase patient satisfaction. Nuclear medicine and imaging tests from examines at Asan Medical Center, Seoul, from March 2008 to December 2008, were analyzed for errors. The first stage, from January 2009 to December 2009, established procedures and know-how. The second stage from January 2010 until June 2010 conducted Pre-and Post-filtering assessment, and the third stage from July 2010 until October 2010 consisted of cross-checks and attaching stickers and comparing error cases. Of 92 errors, the 1st, 2nd and 3rd stage had 32 cases, and there were 46 cases after the 4th stage, with the overall errors reduced by 74.3% from 94.6%. In the field of general nuclear medicine, where various kinds of checks are performed according to the patient's needs, analysis, image composition, differing images in PACS, etc, all have the potential for mistakes to be made. In order to decrease error rates, the image can continuously Cross-Check and Confirm diagnosis.

The Necessity and Requirement of Trial Lens Set Standardization (검안렌즈 표준화의 필요성과 규격에 관한 연구)

  • Park, Sang-Yeul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.217-223
    • /
    • 2006
  • The purpose of this study is to provide improvements and standards of trial lens, in a situation that there is a lack of standards of trial lens set that have been used for self-conscious refraction test after helm refraction test at about 5,000 opticians, ophthalmologic clinics and hospitals, and contact-lens shops, that there is a lot of discrepancies between refraction specified and the actual power, and that there is no regulation of optical tolerance error. For the study, opticians who have used Trial lens set were asked to participate in a questionnaire survey through continuing education, and divided into those who have used domestic lens and those who have used imported lens, 5 opticians each for less than 5 years, 5 to 10 years, more than 10 years. The measurement of both refraction specified and the actual diopter was compared to Japan Industrial Standards(JIS T4402). As a result of comparative analysis, more than 80% of respondents have had reliability on the refraction of trial lens they had used, indicating that they have never measured the refraction specified and the actual diopter after buying them. Besides, Korean Industrial Standards(KS P4402) has been imperfect in diopter range since it was legislated in 1979. More than 95% of respondents have been unsatisfied with optometry. Also, it has indicated that refraction error is more frequent in long-term-used trial lens. The conclusion is that it is necessary to standardize trial lens set and that it is required to add lens to lens set provided under KS P4402. Moreover, it is necessary to have supervisory agency for a standardization of trial lens. I hope that both domestic lens and imported lens, as in German and Japan, will be tested to find whether they meet optical tolerance error and standard trial lens will be distributed. Good optic inspection is required for the improvement and management of eye health and optical function, and the same standard trial lens set should be used. whoever is tested. Also, I hope that trial lens set will be specified within standards and tolerance error.

  • PDF

Evaluation of Usefulness of SPECT-CT at the Examination of Digestive System Leakage Patients (소화기계 Leakage 환자 검사 시 SPECT-CT의 유용성 평가)

  • Ham, Jun Cheol;Oh, Shin Hyun;Choi, Yong Hoon;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.98-102
    • /
    • 2018
  • Purpose When examining patients with digestive system Leakage, it is not easy to distinguish between bile leakage and bleeding only with Planar images. I would like to evaluate the utility of leakage of bile, confirmation of gastrointestinal bleeding and location discrimination using SPECT-CT. Materials and Methods SPECT-CT was performed according to the request of the reading room after acquiring Planar image for a total of 13 patients, including 8 patients suspected of bile leakage and 5 patients suspected of gastrointestinal bleeding, among patients visiting this specification went. We used Symbia T16 from SIEMENS and Discovery 670 from GE. Planar and SPECT-CT images were evaluated with a score of 1 to 10 by 4 experienced nuclear medicine doctors. Using the sensitivity and the specificity, the evaluation of the inspection by the ROC curve was carried out. The final diagnosis was confirmed by follow-up observation as a result of reoperative surgery. Results The sensitivity, specificity and accuracy of SPECT-CT were 91.7%, 100% and 94.2%, respectively. Planar images were 83.3%, 68.8% and 78.8%, respectively. Planar images showed lower diagnostic accuracy compared to SPECT-CT (78.8%, 94.2%, p<0.05). Moreover, the reliability of the diagnosis of SPECT-CT by ROC curve analysis showed a more useful result than the Planar image (p<0.05). Conclusion SPECT-CT had high sensitivity and specificity for diagnosis of biliary leakage and gastrointestinal bleeding and location discrimination. When SPECT-CT is additionally performed together with Planar images, it may be considered to improve bile leakage and diagnosis of gastrointestinal bleeding patients and position discrimination evaluation. There is usefulness depending on the patient's age and position, but consideration of additional CT exposure may be done sufficiently.

A Study on the Analysis of Difference between IT and Non-IT Companies on the Smart Work Environment Continuous Use Intention - Focusing on Korean Small and Medium Enterprises (스마트워크 환경에서 지속사용의도에 대하여 IT기업과 비IT기업 간의 차이분석에 관한 연구 -한국 중소기업을 중심으로)

  • Jung, Soo-Yong;Shin, Yong-tae
    • Journal of Digital Convergence
    • /
    • v.16 no.3
    • /
    • pp.249-259
    • /
    • 2018
  • This research had intended to find out regarding the present influences of the Smart Work on the intention to use continuously with the staff members working in the small- and medium-sized enterprises as the subject. And, finally, it had intended to find out about the Smart Work environments of the IT corporations and the non-IT corporations. For this research, the questionnaire survey data were collected from the staff members working at the small- and medium-sized enterprises. Through the questionnaire survey data that were collected, an empirical analysis was carried out. And, through the reliability analysis, the feasibility analysis, the discriminatory feasibility analysis, and the inspection of the degree of suitableness of the structural equation model, finally, the research model was verified and, finally, a difference analysis of the IT corporations and the non-IT corporations was carried out. Regarding the results of the analysis of the research, it appeared that the factors of the job efficiency and the job autonomy of the special characteristics of the job had the positive influences on the usefulness and the job satisfaction, which were the parameters and which were perceived. And it appeared that the time flexibility of the job form could not have any influences on the usefulness and the job satisfaction, which were the parameters and which were perceived. And it appeared that the spatial flexibility had the influences on the job satisfaction only. The perceived usefulness, which was a parameter, had the positive influences on the job satisfaction and the intention to use continuously. And, finally, the job satisfaction had the positive influences on the intention to use continuously. And it appeared that there were the differences, too, between the IT corporations and the non-IT corporations. It is thought that, through the results of this research and through the Smart Work environment, the positive influences on the workers and the organizations could be induced and that a better working environment than previously can be provided to the workers to fit the special characteristics of the corporations.

Optimization for Underwater Welding of Marine Steel Plates (선박용 강판의 수중 용접 최적화에 관한 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 1984
  • Optimizing investigation of characteristics of underwater welding by a gravity type arc welding process was experimentally carried out by using six types of domestic coated welding electrodes for welding of domestic marine structural steel plates (KR Grade A-1, SWS41A, SWS41B,) in order to develop the underwater welding techniques in practical use. Main results obtained are summarized as follows: 1. The absorption speed of the coating of domestic coated lime titania type welding-electrode became constant at about 60 minutes in water and it was about 0.18%/min during initial 8 minutes of absorption time. 2. Thus, the immediate welding electrode could be used in underwater welding for such a short time in comparison with the joint strength of in-atmosphere-and on-water-welding by dry-, wet-or immediate-welding-electrode. 3. By bead appearance and X-ray inspection, ilmenite, limetitania and high titanium oxide types of electrodes were found better for underwater-welding of 10 mm KR Grade A-1 steel plates, while proper welding angle, current and electrode diameter were 6$0^{\circ}C$, above 160A and 4mm respectively under 28cm/min of welding speed. 4. The weld metal tensile strength or proof stress of underwater-welded-joints has a quadratic relationship with the heat input, and the optimal heat input zone is about 13 to 15KJ/cm for 10mm SWS41A steel plates, resulting from consideration upon both joint efficiency of above-100% and recovery of impact strength and strain. Meanwhile, the optimal heat input zone resulting from tension-tension fatigue limit above the base metal's of SWS41A plates is 16 to 19KJ/cm. Reliability of all the empirical equations reveals 95% confidence level. 6. The microstructure of the underwater welds of SES41A welded in such a zone has no weld defects such as hydrogen brittleness with supreme high hardness, since the HAZ-bond boundary area adjacent to both surface and base metal has only Hv400 max with the microstructure of fine martensite, bainite, pearlite and small amount of ferrite.

  • PDF

A Study on the Evaluating Standards On-Line Service for Archives (기록관의 온라인 서비스 향상을 위한 웹사이트 평가기준설계에 관한 연구)

  • Lee, Yoon-Ju
    • The Korean Journal of Archival Studies
    • /
    • no.16
    • /
    • pp.147-200
    • /
    • 2007
  • Archives provide users with easier and more convenient access to and use of archival data through their Internet websites. Now, archival websites function not only as a tool of information provision or marketing, or as a gateway of Internet-based materials, but also as cyber space for all services of archives, providing users with information and knowledge and direct accessibility to the services in the archives. At present, Korean archives are proceeding with establishing websites or upgrading existing websites, and the use rates and reliability of web services by users are becoming higher. However, although there have been various studies for the evaluation of general websites, few are found with regard to the evaluation of archival websites. It is necessary for archival websites that provide information service to users of every stripe to make more efforts and have more interest in user-centered convenience, right to know, and information provision-centered service. Accordingly, needless to say, it is necessary to study evaluation criteria of websites so that high quality archival websites can be established. With this background, this study establishes evaluation criteria for archival websites, which are appropriate to their objectives and functions and directly evaluates archives, presenting ways to establish and redevelop archival websites. More detailed purposes are as follows: First, analyzes existing theories of evaluation through reviews on previous literature and elicits evaluation criteria for websites, which are appropriate to archives; Second, based on the elicited evaluation criteria for archival websites, examines the current state of domestic archival websites through analytic evaluation; and Third, presents ways to improve archival websites that may be helpful in establishing or improving them in the future. The expectancy effects of this study are as follows: First, it will be helpful when one wishes to identify the current state of archival websites and to improve or redevelop existing websites, or to develop online service through website; Second, it will function as a checklist when a developer who is to establish an archival website wishes to develop evaluation criteria; and Third, it may be used as an inspection tool when an archives contracts out the establishment of its website.

Numerical Analyses for Evaluating Factors which Influence the Behavioral Characteristics of Side of Rock Socketed Drilled Shafts (암반에 근입된 현장타설말뚝의 주면부 거동에 영향을 미치는 변수분석을 위한 수치해석)

  • Lee, Hyuk-Jin;Kim, Hong-Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6C
    • /
    • pp.395-406
    • /
    • 2006
  • Drilled shafts are a common foundation solution for large concentrated loads. Such piles are generally constructed by drilling through softer soils into rock and the section of the shaft which is drilled through rock contributes most of the load bearing capacity. Drilled shafts derive their bearing capacity from both shaft and base resistance components. The length and diameter of the rock socket must be sufficient to carry the loads imposed on the pile safely without excessive settlements. The base resistance component can contribute significantly to the ultimate capacity of the pile. However, the shaft resistance is typically mobilized at considerably smaller pile movements than that of the base. In addition, the base response can be adversely affected by any debris that is left in the bottom of the socket. The reliability of base response therefore depends on the use of a construction and inspection technique which leaves the socket free of debris. This may be difficult and costly to achieve, particularly in deep sockets, which are often drilled under water or drilling slurry. As a consequence of these factors, shaft resistance generally dominates pile performance at working loads. The efforts to improve the prediction of drilled shaft performance are therefore primarily concerned with the complex mechanisms of shaft resistance development. The shaft resistance only is concerned in this study. The nature of the interface between the concrete pile shaft and the surrounding rock is critically important to the performance of the pile, and is heavily influenced by the construction practices. In this study, the influences of asperity characteristics such as the heights and angles, the strength characteristics and elastic constants of surrounding rock masses and the depth and length of rock socket, et. al. on the shaft resistance of drilled shafts are investigated from elasto-plastic analyses( FLAC). Through the parametric studies, among the parameters, the vertical stress on the top layer of socket, the height of asperity and cohesion and poison's ratio of rock masses are major influence factors on the unit peak shaft resistance.