• Title/Summary/Keyword: Inspection Criteria

Search Result 377, Processing Time 0.027 seconds

A Research Study on Seoul Region School Nutritionists' Perception of HACCP System, CCP Control Standards & Performance Conditions and Sanitation & Safety Inspection - Focusing on CCP 1 & CCP 2 - (서울지역 학교 영양(교)사의 HACCP 시스템 CCP 관리기준 수행실태 및 위생·안전점검에 대한 인식 조사 연구 - CCP 1과 CCP 2를 중심으로 -)

  • Kim, Gyoung-Mi;Lee, Ae-Rang
    • The Korean Journal of Food And Nutrition
    • /
    • v.27 no.3
    • /
    • pp.447-457
    • /
    • 2014
  • A research was conducted on Seoul regional elementary, middle, and high school nutritionists to study about their perception of HACCP control standards & performance conditions and sanitation & safety inspection, to seek for more efficient methods of school meals' sanitation system settlement. All surveys were distributed and collected via email. A total of 305 survey papers were collected, and out of these, 300 school results were analyzed. As for CCP 1 performance conditions, 43.3% of the nutritionist put emphasis on temperature control for cooking duration and 71.0% said that they manage both temperature and PHF food control. In CCP 2 stage, 65.8% of the nutritionists maintained the food's temperature, and 56.7% documented the recordings after cooking. A total of 79.3% of the schools scored above 90 points on school meal sanitation & safety inspection, 3.72 points on necessity for revisions, 3.38 points on objectivity, and 3.34 points on reliability. As for these results, a clear CCP control criteria as well as training must be set. Also, because the necessity of revision for sanitation & safety inspection is higher than reliability and objectivity, appropriate complementary measures must be taken.

Exploring the Causal Relationships in the Criteria for Excellence Performance of China

  • Ma, Yizhong;Ree, Sang-Bok
    • International Journal of Quality Innovation
    • /
    • v.9 no.3
    • /
    • pp.145-162
    • /
    • 2008
  • Since the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China published the GB/T19580-2004: Criteria for Excellence Performance of China, many enterprises in China have adopted the Criteria to enhance their organization business management and to assess or self-assess organization performance. On the bases of both the Criteria for Excellence Performance of China and the survey data from China Association for Quality (CAQ), this paper systematically explores the relationships among 'leadership', 'strategy planning', 'customer and market', 'information, analysis and improvement', 'resources management', 'process management', and 'performance results' by using structural equations modeling and validates some of the anecdotal beliefs in quality management. This quantitative analysis provides a guideline for organizations in China to identify causal linkage among core value of total quality management and to identify strengths, deficiency, and opportunities to enhance competitive advantages and ensure the future business success.

A Study on the Mismatch of Time and Frequency Domain for Vibration Criteria of Sensitive Equipment (고정밀 장비의 진동허용규제치에 대한 시간 및 주파수 영역에서 나타나는 불일치 문제에 관한 연구)

  • 이홍기;김강부;전종균;백재호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1376-1383
    • /
    • 2001
  • Modem technology depends on the reliability of extremely high technology equipments. In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a sub-micrometer. This equipment requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga and tera class semiconductor wafers. This high technology equipments require very strict environmental vibration standard, vibration criteria, in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria of high sensitive equipment should be represented in the form of 'exactness' and 'accuracy', because this is used as basic data for the design of building structure and structural dynamics of equipment. This paper deals with the properties of time and frequency domain in order to obtain more improved vibration criteria for high sensitive equipment.

  • PDF

Development of Welding Quality Vision Inspection System for Sinking Seat (차량용 싱킹시트의 용접품질 비젼 검사 시스템 개발)

  • Yun, Sang-Hwan;Kim, Han-Jong;Moon, Sang-In;Kim, Sung-Gaun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1553-1558
    • /
    • 2007
  • This paper presents a vision based autonomous inspection system for welding quality control of car sinking seat. In order to overcome the precision error that arises from a visible inspection by operator in the manufacturing process of a car sinking seat, this paper proposes the MVWQC (machine vision based welding quality control) system. This system consists of the CMOS camera and NI machine vision system. The image processing software for the system has been developed using the NI vision builder system. The geometry of welding bead, which is the welding quality criteria, is measured by using the captured image with median filter applied on it. Experiments have been performed to verify the proposed MVWQC of car sinking seat.

  • PDF

Reliability-Based Managing Criteria for Cable Tension Force in Cable-stayed Bridges (신뢰성에 기초한 사장교 케이블 장력 관리기준치 설정)

  • Cho, Hyo-Nam;Kang, Kyung-Koo;Cha, Cheol-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.129-138
    • /
    • 2005
  • This paper presents a methodology for the determination of optimal managing criteria for cable tension force in cable-stayed bridges using acceleration data acquired by monitoring system. There are many long span bridges installed with monitoring system in Korea. The monitoring systems are installed to diagnose abnormal behavior or damages in bridges and to warn these to bridge management agency. In cable-stayed bridges, the cable tension force could be an important indicator of abnormal behavior because of the geometric configuration of the cable-stayed bridge. If the management value of cable tension force is set too high or too low, then the monitoring system could not warn properly for the abnormal behavior of a bridge. Generally, the management value is set by empirical or engineering judgment, but in this paper, a new methodology for the determination of managing criteria for cable tension force is proposed based on the probability distribution model for tension force and reliability analysis. The proposed methodology is applied to a real concrete cable-stayed bridge in order to investigate its applicability.

On the Improvement for Design Methods of Luminaire Supports Based on the Structural Safety (구조안전성 기반의 가로등주 설계개선방안)

  • Jung, Soo Hyung;Shim, Jae Soo;Choi, Hyun Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.45-55
    • /
    • 2012
  • The road luminaires have been treated as subsidiary electric apparatuses in the road although they are indispensable facilities which people use the road safely. Because of this misunderstanding, there are not many researches on luminaire supports against the wind loads. Therefore, a typhoon has overturned or damaged many luminaire supports without having sufficient structural safeties. The purpose of this study is to review the current design criteria and to suggest the improvement of design methods based on the structural safety and compatible with the site conditions of luminaire supports. The stress concentration around the inspection hole, which causes the collapse of luminaire supports, is analyzed and stress reduction method is suggested with the improved design methods.

A Study on the Improvement of Member Evaluation Method in the Condition Evaluation of Reinforced Concrete Buildings (철근콘크리트 건축물의 상태평가 중 부재평가방법 개선에 관한 연구)

  • Woo, Hye-Sung;Yi, Waon-Ho;Hwang, Kyung-Ran;Lee, Kwan-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.85-91
    • /
    • 2021
  • Type 1 and type 2 buildings must regularly conduct precise safety inspections and precise safety diagnosis for the safety and maintenance of facilities, and the safety grade of the building is determined according to the results of the implementation. In addition, the cycle of inspection and diagnosis is determined according to the safety grade of the building. In order to determine the safety grade of the building, a precise safety inspection conducts condition evaluation, and a precise safety diagnosis conducts condition evaluation and safety evaluation. Therefore, since the inspection and diagnosis cycle is determined according to the safety grade of the building, the condition evaluation and safety evaluation must be precise. However, in the case of member unit evaluation, which is the first step in evaluating the current condition, the evaluation grade is determined by using the representative value of the measurement result, and this may result in an error in the evaluation grade. To solve this problem, this study analyzed evaluation criteria for each evaluation item and presented evaluation criteria using inequalities to respond to measurement results and evaluation scores. In addition, we present a functional formula that can reflect performance scores for each evaluation item.

A Study on the Certification Criteria fot Personal Watercraft Using Electric Power Propulsion (전기 동력 추진식 수상오토바이 인증기준 개발 연구)

  • Kang, Dae-Kon;Kim, Shin-Hyo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.67-72
    • /
    • 2017
  • This study developed an electric power propulsion personal watercraft by combining a battery and an electric system from the domestic automobile industry with water motorcycle from marine leisure industry in a convergence of technology. It also developed a safety inspection plan and type approval standard for personal watercraft that use electric power propulsion. For the registration and production of the electric power PWC (Personal Watercraft), a safety inspection standard (draft) and type approval standard (draft) have been established. PWC that use this electric power propulsion certification standard have been divided into two categories according to the use of gasoline engines as related to the ship's electrical system. The contents of these safety inspections standards is divided into 7 categories, and their purpose is to confirm the facilities used for the safe operation of PWC. Type approval is divided into 7 categories and is intended to ensure the safe production of PWC. This is basic data can be used to establish criteria for safety inspection and type approval of electric power propulsion vessels and to guide the production of the environmentally friendly PWC in Korea.

Review of Revised KOLAS Standard Regulations for Test and Calibration Laboratories: General Requirements for a Competence of Management System (KOLAS 시험 및 교정기관 운영을 위한 개정된 표준 규정 리뷰: 적격성에 대한 일반 요구사항)

  • Kim, Hee Sun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.334-337
    • /
    • 2020
  • Korea Laboratory Accreditation Scheme (KOLAS) introduces a new standard for test and calibration laboratories to operate management system and to produce valid results in accordance with the requirements of KS Q ISO/IEC 17025. The standard is based on the national standard law for the accreditation of test, inspection and calibration laboratories. International Laboratory Accreditation Cooperation (ILAC) has recently established its new criteria. The accredited test and calibration laboratories should complete the transition of their management system by November 2020 following KS Q ISO/IEC 17025:2017. A total of 899 of test, inspection and calibration laboratories in Korea are influenced by the transition policy. This paper summarized general requirements for a competence of laboratory management system.