• 제목/요약/키워드: Insoluble hexavalent chromium

검색결과 6건 처리시간 0.021초

국내 크롬 및 그 화합물의 노출실태 및 노출기준 개정 제안 (Proposals to Revise the Occupational Exposure Limits for Aluminum in Korea)

  • 김승원;피영규;백용준;정태진;한정희
    • 한국산업보건학회지
    • /
    • 제34권2호
    • /
    • pp.166-178
    • /
    • 2024
  • Objectives: The 12 occupational exposure limits(OELs) for chromium and its compounds in Korea were set by applying the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs). However, this is significantly different from the TLVs after the existing TLVs were integrated and withdrawn in 2018, so it is necessary to review the revision. Methods: Various documents related to chromium OELs were reviewed, including the ACGIH TLV Documentations for chromium and its compounds. A field survey was conducted targeting workplaces handling chromium and its compounds. Based on this, a revised OELs were proposed and a socio-economic evaluation was conducted. Results: The OELs for chromium compounds in Korea was first enacted in 2002, and in 2007, the OELs for chromium (hexavalent) compounds (insoluble) was lowered from 0.05 mg/m3 to 0.01 mg/m3. In 2008, the OELs for strontium chromate was newly established as 0.0005 mg/m3, and in 2018, the OELs for calcium chromate was newly established as 0.001 mg/m3. Total chromium and hexavalent chromium were measured for each of 6 samples at 2 welding sites, 4 plating sites, and 2 spray coating sites. When omparing the average of the results measured by ICP, a total chromium analysis method, and the analysis results by IC, a hexavalent chromium analysis method, only workplace 4 was the same, and total chromium was evaluated more, and total chromium was evaluated at 0.0004 to 0.0027 mg/m3. And hexavalent chromium was evaluated as non-detection ~ 0.0014 mg/m3. Amendment ①: The exposure standard for hexavalent chromium is not divided into water soluble, insoluble, chromium ore processing, and other hexavalent chromium compounds, and is integrated into 0.01 mg/m3, which is the level of chromium (hexavalent) compound (insoluble)., OELs for chromium (metal) and chromium (trivalent) compounds are integrated into chromium (trivalent) compounds, and the exposure level is maintained. Amendment ②: As in the amendment ①, the OELs are integrated, but the level is lowered to 0.005 mg/m3, which is the OELs of OSHA, and there is a grace period of 4 years. Amendment ③: As in the amendment ①, the OELs are integrated, but the level is lowered to 0.0002 mg/m3, which is the exposure standard of ACGIH, and there is a grace period of 5 years. Conclusions: Amendment ①: The change in the OELs is insignificant, so the cost required is small, and the benefit/cost ratio is greater than 1, so there is no problem in applying the amendment. Amendment ②: In all scenarios except chromium 6(insoluble), the benefit/cost ratio is greater than 1, so it is thought that there will be no major problem in applying the amendment. Amendment ③: Since the benefit/cost ratio is less than 1 in all scenarios, it is thought that the total social benefit that can be obtained when applying the amendment is not large.

전처리방법에 따른 불용성 6가 크롬 분석에 관한 연구 (Pretreatment Effect on the Analysis of Insoluble Hexavalent Chromium)

  • 이은정;노재훈;원종욱;전미령;조명화;김치년
    • 한국산업보건학회지
    • /
    • 제6권2호
    • /
    • pp.292-300
    • /
    • 1996
  • Hexavalent chromium($Cr^{+6}$) compounds are considered to be particularly hazardous, primarily because of the associated risk of allergic reaction and cancer. The analytic method of hexavalent chromium such as the s-diphenylcarba-zide(DPC) method and all ether previously used methods are often made uncertain due to significant interferences from organic components. This report can provide a technique for the more rapid and simple determination of total hexavalent chromium. than other currently using methods. The s-diphenylcarbazide method proposed by the U.S. National Institute for Occupational Safety and Health has low recovery rate(15.67 - 48.20%) due to interference, iron chloride and nickel chloride. A microwave oven technique has high recovery rate(about 70%) of insoluble hexavalent chromium. For the difference of ionic charges of $Cr^{+3}$-ethylenediamine tetraacetic acid(EDTA) chelate and $CrO_4{^{-2}}$, we could detect them simultaneously by ion exchanged high performance liquid chromatography. The confirmation of $Cr^{+3}$ and $Cr^{+6}$ were checked by fraction collector and flameless atomic absorption spectrometer. We observed that the small amount of hexavalent chromium is converted to trivalent chromium due to enhancement of chromium reduction by $Fe^{+3}$ or $Ni^{+2}$. As a result of this study, on the analysis of insoluble hexavalent chromium with microwave oven was used for, it may be better and more precise analysis after pretreatment by 2% NaOH-3% $Na_2CO_3$ and then analysis UV-spectrophotometer. It should be done for various studies on insoluble hexavalent chromium on the basis work environmental monitoring so called welding, painting etc.

  • PDF

용해도에 따라 노출기준이 다른 금속화합물의 정량방법 고찰 (Review of the Determination Methods for Metal Compounds with Different Occupational Exposure Limits Depending on Solubility)

  • 박승현;노지원;장미연
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.87-98
    • /
    • 2020
  • Objective: The purpose of this study was to propose a sequential procedure for the simultaneous analysis of soluble and insoluble metal compounds. Methods: Methods for sampling and analyzing metal compounds such as ISO standards, NIOSH methods, HSE methods, and OSHA methods were reviewed. Results: Some metals have different OELs depending on the solubility of the compound. Therefore, we should take into account these characteristics and perform an exposure assessment. Soluble metal compounds are first extracted from the filter, and then the filter is digested by acids to analyze residual insoluble components. The extraction of soluble compounds can be completed by agitation for about 60 minutes with a leach solution (water) in a water bath at 37℃. For the analysis of insoluble compounds, the sample filter and the filtration filter remaining after the extraction of the soluble compounds are analyzed. This allows simultaneous determination of soluble and insoluble metal compounds. For hexavalent chromium compounds, soluble hexavalent chromium can first be extracted from the filter by using sulfate buffer. The insoluble hexavalent chromium remaining in the filter can then be extracted using carbonate buffer. Conclusion: Workers are often exposed to many hazardous substances with different exposure limits at industrial sites. The OELs for compounds of the same metal can be set differently depending on solubility. This study can help evaluate a worker's exposure to metal compounds by suggesting methods for the simultaneous determination of soluble and insoluble metal compounds.

Hexavalent Chromium Reduction by Bacteria from Tannery Effluent

  • Batool, Rida;Yrjala, Kim;Hasnain, Shahida
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권4호
    • /
    • pp.547-554
    • /
    • 2012
  • Chromium is generated from several industrial processes. It occurs in different oxidation states, but Cr(III) and Cr(VI) are the most common ones. Cr(VI) is a toxic, soluble environmental contaminant. Some bacteria are able to reduce hexavalent chromium to the insoluble and less toxic Cr(III), and thus chromate bioremediation is of considerable interest. An indigenous chromium-reducing bacterial strain, Rb-2, isolated from a tannery water sample, was identified as Ochrobactrum intermedium, on the basis of 16S rRNA gene sequencing. The influence of factors like temperature of incubation, initial concentration of Cr, mobility of bacteria, and different carbon sources were studied to test the ability of the bacterium to reduce Cr(VI) under variable environmental conditions. The ability of the bacterial strain to reduce hexavalent chromium in artificial and industrial sewage water was evaluated. It was observed that the mechanism of resistance to metal was not due to the change in the permeability barrier of the cell membrane, and the enzyme activity was found to be inductive. Intracellular reduction of Cr(VI) was proven by reductase assay using cell-free extract. Scanning electron microscopy revealed chromium precipitates on bacterial cell surfaces, and transmission electron microscopy showed the outer as well as inner distribution of Cr(VI). This bacterial strain can be useful for Cr(VI) detoxification under a wide range of environmental conditions.

국제표준규격에 의한 입자상 물질 중 발암성 금속의 평가 (Evaluation of Carcinogenic Metals in Particulate Using New ISO Standard Method)

  • 박지영;윤충식;하권철
    • 한국산업보건학회지
    • /
    • 제18권2호
    • /
    • pp.99-107
    • /
    • 2008
  • We quantified the human carcinogenic metals (chromium, nickel) in fumes from flux cored arc welding using stainless steel (FCAW/SS) wires. Zinc and calcium were also quantified because of their possibility of zinc chromate and calcium chromate, respectively. Welding was performed in an American Welding Society standard fume collection chamber. Insoluble and soluble forms of metals were analyzed by ISO 15202 method. Total chromium (insoluble+soluble) content and total nickel content were lower in FCAW/SS fumes (4.65%, 1.05%, respectively)than in stainless steel content (ca. 18%, 8%,respectively). Insoluble fraction in total chromium was 79.8 (range 64.5~95.1)% and 94.4(range 90.1~98.1)% in total nickel. Atomic emission spectroscopy used in this study does not differentiate the chromium valence status while ACGIH defines its carcinogenicity according to the valence status. From this study and previous study, we estimated the hexavalent chromium content in FCAW/SS was 0.2~1.1% and about 85% of them was soluble. The content of zinc and calcium, which can be existed as chromate forms, was low (0.02 %, 0.04% respectively) in FCAW/SS. Exposure assessment for zinc chromate and calcium chromate is possible because chromium in both compounds is used as a surrogate even though it is not well known that what compounds of zinc and calcium are formed in welding fume.

고농도 6가 크롬 도금 폐수 처리 (Treatment of high hexavalent chromium plating wastewater)

  • 강창덕;심상준;황석훈
    • 청정기술
    • /
    • 제7권1호
    • /
    • pp.75-80
    • /
    • 2001
  • 본 연구에서는 강산성 상태에 있는 고농도의 6가 크롬 도금 폐수를 환원 및 중화의 방법으로 처리하였다. 환원제로는 강산성 상태에서 급격히 빠른 속도로 6가 크롬을 3가 크롬으로 환원시키는 황산제일철($FeSO_4$)이 사용되었고, 원수의 크롬농도에 대해 몰비로 3배의 양이 필요한 것으로 확인되었다. 환원된 3가 크롬은 석회석이 충진되어 있는 회분식 석회석탑에서 폭기에 의해 중화되었고, pH 5.0 이상으로 중화되었을 때 효과적으로 불용성의 크롬수산화물 플럭으로 형성되어 제거되는 것을 확인할 수 있었다. 이와 같은 결과들을 기초로 환원조, 석회석탑, 침전/여과조로 이루어진 6가 크롬 제거 연속공정을 개발하였고, 이 공정을 통해 6가 크롬 폐수의 연속적인 처리를 실행하였다. 석회석탑 내에서의 pH 조건이 pH 5.0 부근에서 일정하게 유지되었고, 그것으로 인해 불용성의 크롬 수산화물 플럭이 효과적으로 형성되었다. 석회석탑에서 침전조로 유도된 플럭은 침전조 내부에 부착된 1450 매쉬 크기의 기공을 지닌 금속 분리막에 의해 최종 처리수와 분리되었고, 막 여과 가동 30분 후부터 배출 허용기준을 만족시키는 크롬 농도 0.25~0.90 mg/l의 최종 처리수를 얻을 수 있었다. 막의 역세척 주기는 초기에 급격히 감소하였고, 이후에는 안정적으로 유지되었다.

  • PDF