• Title/Summary/Keyword: Inside-out method

Search Result 481, Processing Time 0.035 seconds

A Study on The Housing Condition and Planning for The Suburban Housing Complexes (단지형 도시근교주거의 실태 및 주거계획에 관한 연구)

  • Song Bin-Na;Ju Seo-Ryeung
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.141-150
    • /
    • 2005
  • The purpose of this study is to understand the present status of life style and housing demands of residents in Yoing-in and Kwang-Ju in Kyung-Ki province, Korea. Field study methods were carried out practically using participant observation method and open-ended interview method, and the data were gotten by sketch, recording, photograph and memo. As a result, the followings were proposed. First, it was necessary to hide or reduce of the neighborhood's noise or direct view because those people thought the invasion of the privacy problem was very severe. The master planning of the complex method could be an alternative plan for this kind of problems. Second, it was needed to be the planning that could follow up the out-door friendly situations. To achieve this, the in between living space are needed that connected the outside and inside of the house. Third, the planning of the housing space should flexible for each participant's needs of the future. To achieve this, each unit in the suburban housing complexes should be fixed to the each character of the people's various needs.

A Study on the Development of the EMf System Using Personal Computer (개인용 컴퓨터를 이용한 근전도(EMG) 시스템 개발에 관한 연구)

  • 조승진;김민수
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.243-248
    • /
    • 1990
  • EMG (eleltromyographic) signals are generated by contracting muscle and detected in and out side of muscle in the form of random signals. In the measurement of muscle fatigue, the mean frequency of EMG signals using spectrum analysis is an important parameter in diagonosis of muscle disease and in sports medicine fields. In this study, the degree of spectral transfer to lower frequency caused by accumulation of Latic acid inside the muscle is estimated. The new spectral analysis method using 2"d order hAaximum Entropy Method was applied to estimate the mean frequency and we confirmed that this new method yields fast and reliable estimation.tion.

  • PDF

Optimum Design of Surface Aerator Using Response Surface Method (반응표면 기법을 이용한 생물반응조 표면포기기 최적설계)

  • Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.47-55
    • /
    • 2010
  • In this study, we optimized the shape of the surface aerator that will be installed in a biological reactor using the response surface method. Response surfaces of mass flow rate, impeller torque, mass flow rate per impeller torque are generated and used to track the optimum shape of the aerator. MOGA(Multi-Objective Genetic Algorithm)method is adopted to find the optimum results. By increasing the mass flow rate per impeller torque, increase of oxygen supply efficiency to a reactor is anticipated. To verify the usability of the surface aerator, PIV measurements on flow fields inside a scale-downed biological reactor model are carried out.

An Analysis of Partial Discharge by the Optimum Method of Threshold Value (기준치(Threshold Value) 최적화 기법을 이용한 부분방전 해석)

  • Choi, I.H.;Yun, J.W.;Kweon, D.J.;Jung, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2277-2279
    • /
    • 1999
  • We have investigated the characteristic analysis of ultrasonic in case of occurring partial discharge in experimental steel chamber. This study presents the discriminative method of partial discharge by optimum threshold value. We have carried out the experiments of measuring partial discharge numbers between ultrasonic sensor and transducer with changing distance and barrier inside steel chamber. After the measured data were trasformed A/D conversion by GPIB, we used the optimum method of threshold value for counting numbers of partial discharge.

  • PDF

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

A study on Reinforcement Methods to Improve the Usability of the H-beam Backfill Installation Part in Top-Down Construction Method (역타공법 뒷채움재 설치 구간의 사용성 개선을 위한 보강 방안 연구)

  • Shim, Hak-Bo;Jeon, Hyun-Soo;Seok, Won-Kyun;Park, Soon-Jeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.180-180
    • /
    • 2021
  • Recently, structural damage and defect has occurred in the H-beam backfill installation part of Top-Down construction method. In order to secure structural safety and usability in the adjacent section of the backfilling method, It turns out that it is necessary to analyze by dividing into various cases. The H-beam backfill installation section is divided into the case of adding a vertical plate inside the slab, adding a shear stud, adding a reinforcing bar, changing the thickness of the pressure plate, and filling the H-beam backfill with mortar. Ansys modeling was performed and an appropriate solution was suggested by analysis.

  • PDF

A Study on the Prevention of Cracks on the Trepan Area of Motor Bearing

  • Lee, Kyung-Won;Ban, Jae-Sam;Kang, Heyong-Seon;Cho, Kyu-Zong
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.215-220
    • /
    • 2003
  • Trepan prevents the wear of the inside part of a bearing when the initial shaft rotates. It continuously contacts with the eccentric part of the shaft in rotation and is loaded repeatedly. Therefore, even if an early crack of a trepan part is small, the crack may progress by the repeated load. If the crack progresses, very small chips come out. This Is put in the rotor and prevents the rotation of the compressor, There can be leaks in a microgroove and extreme wear can occur due to lack of oil on the surface contact part. Therefore, this study was carried out to compare and investigate the trepan strength and deflection characteristics between trepan locations and dimension changes using the finite element method and search a motor bearing for a model with bigger stiffness of a trepan part and the same deflection.

Study on the Optimal Shape of Low Noise, New Concept Fan for Refrigerator (냉장고용 저소음 신형상홴의 최적 형상에 관한 연구)

  • 정용규;김창준;백승조;전완호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.645-650
    • /
    • 2002
  • In this paper, new concept, low noise axial fan was developed. The fan was designed to operate at high-pressure condition inside the refrigerator. This fan - we call it Alpha fan - has small turbo blades at trailing edge of axial fan. These turbo blades make alpha fan operate at high pressure and low noise condition. In order to find out the optimal value of design parameters, 6-sigma method was used. The design parameters are ratio between inner and outer diameter, Height, Install angle and Install position of turbo blade. Optimal value of turbo blade was found out and the noise generated from this fan is reduced about 3dB(A).

  • PDF

Prediction of Particulate Matter Being Accumulated in a Diesel Particulate Filter (디젤 매연 필터에서 퇴적되는 입자상 물질의 퇴적량 예측)

  • Yu, Jun;Chun, Je-Rok;Hong, Hyun-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.3
    • /
    • pp.29-34
    • /
    • 2009
  • Diesel particulate filter (DPF) has been developed to optimize engine out emission, especially particulate matter (PM). One of the main important factors for developing the DPF is estimation of soot mass being accumulated inside the DPF. Evaluation of pressure drop over the DPF is a simple way to estimate the accumulated soot mass but its accuracy is known to be limited to certain vehicle operating conditions. The method to compensate drawback is adoption of integrating time history of the engine out PM and burning soot. Present study demonstrates current status of the soot estimation methods including the results from the engine test benches and vehicles.

SEARCHING FOR THE PROPER SEATING METHOD OF SEAMLESS BANDS WITH UNIFORMLY COATED CEMENT (접착용 시멘트의 균일한 도포를 위한 교정용 밴드 장착방법의 모색)

  • Kim, Hyung-Jun;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.491-497
    • /
    • 2006
  • Orthodontic seamless bands are frequently used in pediatric dentistry. In the process of seating bands with luting cement coated inside, not uniformed coating might bring about various problems such as enamel decalcification and/or gingivitis, and this clinical trial was made to review several band-seating methods to exclude these risks. One kind of band luting cement and one size of seamless bands were used on the resin replicas of an extracted maxillary and mandibular 1st molar with three different seating methods 1. seating the band with the luting cement coated only inside the band, 2. seating the band with the luting cement coated inside the band and on axial surfaces of the teeth, 3. seating the band with the adhesive tape on the occlusal opening of the band and the luting cement coated only inside the band. After cement was completely set, bands were peeled off from the teeth and the status of cement coating was evaluated. With this experiment more uniformed coating of the luting cement was found in latter two groups. These methods are thought more appropriate to almost completely rule out the risk of unevenly coated cement beneath the bands by conventional method.

  • PDF