• Title/Summary/Keyword: Input-output Efficiency

Search Result 1,246, Processing Time 0.023 seconds

A 3-Bridge LLC Resonant Converter with Wide Input/Output Voltage Gain Characteristics (넓은 입·출력 전압이득 특성을 갖는 3 브리지 LLC 공진컨버터)

  • Yoo, Sang-Jae;Jang, Ki-Chan;Kim, Eun-Soo;Jeon, Yong-Seog;Kook, Yoon-Sang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.142-151
    • /
    • 2020
  • This paper presents a DC/DC LLC resonant converter with wide input/output voltage gain characteristics and its control method for efficiency improvement. For a wide input/output voltage gain characteristics without designing small transformer magnetization inductance, the proposed converter changes the topology into three modes of operation according to the main switch switching pattern. In each operating mode, variable LINK voltage modulation and frequency modulation were performed to control output voltage and improve operating efficiency. A prototype of a 5-kW DC/DC LLC resonant converter was built and tested to verify the validity and applicability of the proposed converter.

Soft switching high power factor buck converter using loss less snubber circuit (무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터)

  • 구헌회;변영복;김성철;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

A Study on the Output Voltage and Efficiency of the Single-Phase Z-Source Inverters According to Duty Ratio (듀티 비에 따른 단상 Z-소스 인버터의 효율과 출력 전압에 관한 연구)

  • Hong, Seung-Pyo;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.8-19
    • /
    • 2011
  • This paper was compared for the output voltage and efficiency of the single-phase Z-source inverter(ZSI) according to shoot through duty ratio D. The eight single-phase ZSI in this study are typical ZSI, Embedded ZSI(EZSI), Improved ZSI(IZSI), Quasi ZSI(QZSI), Series ZSI, Trans ZSI(TSI), Switched inductor ZSI(SL-ZSI) and Extended boost ZSI (exZSI). The eight ZSI are divided into two Groups. ; Group-1 which is ZSI with the ordinary voltage boost factor B, and Group-2 which is ZSI with the maximum voltage boost factor B. For the execution of the proposed study, the PSIM simulation was achieved under the condition of input DC voltage=150[V] of ZSI, load =30[${\Omega}$] and 60[Hz] output filter. The output voltage and efficiency of each ZSI were calculated within the limits of D=0.1~0.4. As a result, the output peak voltage of Group-2 was suddenly increased in a specified duty ratio D, and its efficiency was rapidly decreased. On the contrary, Group-1 shown the output and efficiency characteristics without sudden change compared to Group-2 despite the duty ratio increase. The efficiency of the Group-2 was sharply declined at duty ratio D of the most output voltage, but, in case of Group-1, the efficiency was slightly declined. Finally, the input DC current of ZSI with DCM and CCM was discussed.

A Study on Sustainable Development Efficiency of Foreign Trade in Western China Based on DEA Model

  • Xu, Yan;Sim, Jae-yeon
    • International journal of advanced smart convergence
    • /
    • v.11 no.2
    • /
    • pp.171-184
    • /
    • 2022
  • The purpose of this paper is output oriented, in order to maximize the output level of sustainable development efficiency of foreign trade in western China with limited input. This paper adopts the relevant input-output indicators of sustainable foreign trade development of 11 provinces and cities in western China from 2016 to 2020, and uses DEA model to measure their technical efficiency, pure technical efficiency and scale efficiency. Malmquist index was used to calculate the total factor productivity change index of each province in western China from 2016 to 2020. We found that, on the whole, the average values of technical efficiency, pure technical efficiency and scale efficiency of provinces and cities in western China from 2016 to 2020 are greater than 0.8, indicating that the western region has high technical efficiency, relatively high management and institutional level and high existing scale level. Scale efficiency is lower than pure technical efficiency on the whole, indicating that the current sustainable development efficiency of foreign trade in western China is mainly limited by its scale level. The technological progress index is higher than the technological efficiency change index, indicating that the total factor productivity of the sustainable development of foreign trade in western China is mainly driven by technological progress and more influenced by external factors. We think the conclusion of this study can provide important reference information for the sustainable development of foreign trade of provinces and cities in western China.

Analysis of Efficiencies for Multiple-Input Multiple-Output Wireless Power Transfer Systems

  • Kim, Sejin;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.2
    • /
    • pp.126-133
    • /
    • 2016
  • Wireless power transfer (WPT) efficiencies for multiple-input multiple-output (MIMO) systems are formulated with a goal of achieving their maximums using Z matrices. The maximum efficiencies for any arbitrarily given configurations are obtained using optimum loads, which can be determined numerically through adequate optimization procedures in general. For some simpler special cases (single-input single-output, single-input multiple-output, and multiple-input single-output) of the MIMO systems, the efficiencies and optimum loads to maximize them can be obtained using closed-form expressions. These closed-form solutions give us more physical insight into the given WPT problem. These efficiencies are evaluated theoretically based on the presented formulation and also verified with comparisons with circuit- and EM-simulation results. They are shown to lead to a good agreement. This work may be useful for construction of the wireless Internet of Things, especially employed with energy autonomy.

Analysis of Input-Output Characteristics for Single-Phase Diode Rectifier (다이오드 정류회로의 입.출력 특성해석)

  • 한창영
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.299-304
    • /
    • 2000
  • In this paper we investigate accurately the input-output characteristic of single-phase diode rectifier. The diode rectifier has some advantages of simplicity cost and high-efficiency. But it has some defects which THD of input current low PF and voltage drop of output side. In order to compensate it we analyzed using the parameter variation and introduced capacitor insertion method for reducing the distortion and increasing the PF.

  • PDF

Characteristics Analysis of Induction Generator with a Change in Rotor Speed (회전속도 변화에 따른 유도발전기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung;Kim, Young-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2225-2229
    • /
    • 2011
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. However, many engineer are unfamiliar with the induction generator, even though no difference exists between both machines except for the mode of operation. But an induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load, total efficiency is decreased. In this paper, we analyzed that input, output, torque and efficiency is different from each other above and below synchronous speed.

The Efficiency Evaluation of Coking Coals Using Data Envelopment Analysis (DEA 모형에 의한 제철용 석탄의 효율성 평가)

  • Seong, Deok-Hyun;Suh, Min-Soo
    • Journal of Information Technology Services
    • /
    • v.10 no.2
    • /
    • pp.177-188
    • /
    • 2011
  • This paper proposes a DEA model for the performance evaluation of each brand of coking coals in an integrated steel mill. The performance is defined as the efficiency which is the ratio of two linear combinations of the output factors to the input factors. There is only one input factor considered in the model : unit price of each brand based on CIF. Five output factors are chosen in consideration of their impact to the quality of cokes such as Ash, VM, LMF, TD, and Rm. Some of the output factors are treated as undesirable in DEA model because the quality criteria are given by the range. The CCR and BCC efficiencies are derived by the DEA model, and the scale efficiency is calculated, too. Each brand of coking coal is classified into four categories according to the CCR and BCC efficiencies, and the most inferior brands are identified as a result. The impact of the input and output factors to the efficiency is analyzed using a multiple regression, then the unit price is revealed as the most critical among them. Also, ANOVA results show that there exist efficiency differences among the coal types and the countries imported, respectively. Finally, the quantitative projection for the inefficient brands is performed if they are to be efficient. The result could be utilized in selecting the good or bad brands of coking coal based on the efficiency in an integrated steel mill. Also, this model will be used to assess the relative efficiency of a new brand of coking coal if it is a candidate to be imported.

Design Principles and Validation of a Human-sized Quadruped Robot Leg for High Energy Efficiency (에너지 효율적인 인간 크기 4족 보행 로봇의 설계와 검증)

  • Yeom, Hoyeon;Ba, Dang Xuan;Bae, Joonbum
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.2
    • /
    • pp.86-91
    • /
    • 2018
  • This paper presents about design efforts of a human-sized quadruped robot leg for high energy efficiency, and verifications. One of the representative index of the energy efficiency is the Cost of Transport (COT), but increased in the energy or work done is not calculated in COT. In this reason, the input to the output energy efficiency should be also considered as a very important term. By designing the robot with customized motor housing, small rotational inertia, and low gear ratio to reduce friction, high energy efficiency was achieved. Squatting motion of one leg was performed and simulation results were compared to the experimental results for validation. The developed 50 kg robot can lift the weight up to 200 kg, and during squatting, it showed high energy efficiency. The robot showed 71% input to output energy efficiency in positive work. Peak current during squatting only appears to be 0.3 A.

Harmonic Waveforms Analysis and Efficiency Measurement of Inverter for driving Induction Motors (유도형 모터 구동용 인버터의 고조파 파형 분석과 효율 측정)

  • Jang, Seok-Myeong;Jeong, Sang-Sub;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.282-284
    • /
    • 1997
  • The harmonics are injurious on the operation of the motor, electric instruments etc. In this paper, it is certified the capability of the electric measuring devices at the input/output of inverter. And it is measured the harmonics of the voltage and current waveforms. Also, this paper presents the efficiency of the inverter's power conversion by measuring the fundamental and total power at the input, DC bus and output.

  • PDF