• 제목/요약/키워드: Inorganic scintillator

검색결과 15건 처리시간 0.024초

무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가 (Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material)

  • 황영묵;조동현;이봉수;조효성;김신
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 2005
  • In this study, radiation sensor tips are fabricated for remote sensing of X or gamma ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by radiation source is guided by the plastic optical fiber and is measured by optical detector and power-meter. Two kinds of sensor tips are designed and fabricated such as film type and powder type. Many kinds of inorganic scintillators are used to fabricate both sensor tips, and the different wavelength of emitting lights from them are measured to determine the optimal inorganic scintillator which has maximum light output. As a radiation source X-ray generator and Ir-192 are selected to test a performance of sensor tip. It is expected that the fiber-optic radiation sensor is widely used in nuclear industry and medical applications due to its special characteristics such as good flexibility, easy in processing, long lengths and no interference to electro magnetic field.

표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가 (Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test)

  • 서범경;이근우;임난주;박진호;한명진
    • 에너지공학
    • /
    • 제13권2호
    • /
    • pp.93-100
    • /
    • 2004
  • 간접법을 이용한 표면오염도 측정 시 시료채취와 동시에 방사선 검출이 가능한 스메어 매체를 제조하고 성능을 평가하였다. 스메어 매체는 무기섬광체를 고분자 막에 함침시킨 것으로서, 용매로는 디메틸포름아마이드(DMF)와 메틸렌클로라이드(MC) 그리고 고분자 소재로서 폴리설폰(PSF)을 사용하였고, 무기섬광체는 CAYS(cerium activated yttrium silicate)를 사용하였다. 함침막은 단일 및 이중구조로 제조하였고, 물. 메타놀 등 비용매성 욕조에 침지하거나 용매 증발을 통하여 고형화하여 특성을 비교하였다. 방사선과의 상호작용에 의하여 무기섬광물질 함침막으로부터 방출되는 광자의 계측은 광전증배관과 고전압원, 증폭기. 계수기로 구성된 원형계수기를 사용하였다. $^{14}$ C표면오염에 대해 무기섬광 함침막을 이용해 얻은 계수율을 통상의 저준위 알파/베타 계수기로 얻은 결과와 비교할 때 상대 감도가 약 50%로 나타났다. 또한, 계수효율이 상대적으로 낮았지만 저에너지 베타선 방출핵종인 $^3$H표면오염도측정이 가능하다는 것을 확인하였다.

Feasibility study on fiber-optic inorganic scintillator array sensor system for multi-dimensional scanning of radioactive waste

  • Jae Hyung Park;Siwon Song;Seunghyeon Kim;Jinhong Kim;Seunghyun Cho;Cheol Ho Pyeon;Bongsoo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3206-3212
    • /
    • 2023
  • We developed a miniaturized multi-dimensional radiation sensor system consisting of an inorganic scintillator array and plastic optical fibers. This system can be applied to remotely obtain the radioactivity distribution and identify the radionuclides in radioactive waste by utilizing a scanning method. Variation in scintillation light was measured in two-dimensional regions of interest and then converted into radioactivity distribution images. Outliers present in the images were removed by using a digital filter to make the hot spot location more accurate and cubic interpolation was applied to make the images smoother and clearer. Next, gamma-ray spectroscopy was performed to identify the radionuclides, and three-dimensional volume scanning was also performed to effectively find the hot spot using the proposed array sensor.

The Characteristics Study on Detector for In-pipe Radioactive Contamination Counting

  • Seo B. K.;Kim G. H.;Jung Y. H.;Woo Z. H.;Oh W. Z.;Lee K. W.;Han M. J.
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 Proceedings of The 6th korea-china joint workshop on nuclear waste management
    • /
    • pp.269-279
    • /
    • 2005
  • In this study, detectors characteristics for simultaneous counting of alpha and beta ray in a pipe were estimated. The detector were composed of thin ZnS(Ag) scintillator and plastic detector. The scintillator for counting alpha particles has been applied a polymer composite sheet, having a double layer structure of an inorganic scintillator ZnS(Ag) layer adhered onto a polymer sub-layer. The other for counting beta particles used a commercially available plastic scintillator. It was confirmed that the detectors were suitable for counting the in-pipe contamination.

  • PDF

CdS/ZnS 양자점 기반 플라스틱 섬광체 제작 및 성능평가 (Fabrication and Evaluation of CdS/ZnS Quantum Dot Based Plastic Scintillator)

  • 민수정;강하라;이병채;서범경;정재학;노창현;홍상범
    • Korean Chemical Engineering Research
    • /
    • 제59권3호
    • /
    • pp.450-454
    • /
    • 2021
  • 현재, 감마 핵종 분석은 주로 무기섬광체 또는 반도체 검출기를 활용하여 여러 분야에 사용되고 있다. 이러한 검출기는 분해능이 좋지만 크기가 제한적이며, 가공성이 낮고 경제성이 플라스틱 섬광체보다 낮다. 따라서, 나노물질인 양자점과 플라스틱섬광체의 장점을 이용하여 양자점 나노물질 기반 플라스틱 섬광체를 개발하였다. 가장 많이 활용되고 있는 Cd계열 물질인 CdS/ZnS 양자점을 플라스틱 매트릭스에 교반하여 제작하였으며, 이를 60Co핵종 대상 계측 실험을 하여 상용플라스틱 섬광체의 성능과 비교 분석하였다. 상용플라스틱 섬광체 대비 CdS/ZnS 양자점 기반 플라스틱 섬광체가 20~30% 높은 효율을 보였다. 이는 의료분야뿐만 아니라 원자력 해체분야에서도 방사능 분석기로 활용 가능할 것으로 판단된다.

Measurement of Depth Dose Distribution Using Plastic Scintillator

  • Hashimoto, Masatoshi;Kodama, Kiyoyuki;Hanada, Takashi;Ide, Tatsuya;Tsukahara, Tomoko;Maruyama, Koichi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.244-247
    • /
    • 2002
  • We examined a possibility to use inorganic plastic scintillator, which has the effective atomic number close to that of human soft tissue, for the measurement of dose distributions in a shorter time period. The method was to irradiate a block of plastic scintillator as a phantom, and to measure the distribution of the scintillation light by a wave length analyzer through a thread of plastic optical fiber. By irradiating the diagnostic x-ray, we observed the emission spectrum of the scintillation light from the scintillator. It showed a peak at around 420nm with a full width of 140 nm. The emission spectrum was integrated to determine the total number of photons. The dependences of the amount of photons on the irradiated dose were measured. The results of the experiment show that the amount of emission light is in proportional to the irradiated dose. From this fact, we conclude that the present method can be used for the measurement of the depth dose distribution of the diagnostic x-rays.

  • PDF

Beta particle energy spectra shift due to self-attenuation effects in environmental sources

  • Alton, Thomas Theakston;Monk, Stephen David;Cheneler, David
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1483-1488
    • /
    • 2017
  • In order to predict and control the environmental and health impacts of ionizing radiation in environmental sources such as groundwater, it is necessary to identify the radionuclides present. Beta-emitting radionuclides are frequently identified by measuring their characteristic energy spectra. The present work shows that self-attenuation effects from volume sources result in a geometry-dependent shift in the characteristic spectra, which needs to be taken into account in order to correctly identify the radionuclides present. These effects are shown to be compounded due to the subsequent shift in the photon spectra produced by the detector, in this case an inorganic solid scintillator ($CaF_2:Eu$) monitored using a silicon photomultiplier. Using tritiated water as an environmentally relevant, and notoriously difficult to monitor case study, analytical predictions for the shift in the energy spectra as a function of depth of source have been derived. These predictions have been validated using Geant4 simulations and experimental results measured using bespoke instrumentation.

플라스틱 광섬유를 이용한 초소형 의료용 방사선 센서 제작 (Fabrication of Miniature Radiation Sensor Using Plastic Optical Fiber for Medical Usage)

  • 황영묵;조동현;조효성;김신;이봉수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권1호
    • /
    • pp.9-12
    • /
    • 2005
  • 본 연구에서는 엑스선 또는 감마선 원거리 측정용 초소형 방사선 센서를 개발하기 위해서 발광 스펙트럼이 다른 여러 종류의 무기 섬광체를 이용하여 필름형태의 센서부를 제작하였고, 방사선으로부터 발생되는 섬광량을 광검출기 및 광파워미터로 측정하였다. 본 연구 결과, 개발 가능한 방사선 센서는 직경 1 mm의 플라스틱 광섬유를 사용하여 전자기파 장애로부터 간섭을 받지 않음과 동시에 원거리 측정 및 신속, 정확한 방사선 계측이 가능하고 초소형, 초경량의 특성을 지니기 때문에 방사선 치료 시 고 분해능의 방사선 계측이 가능할 것으로 기대된다.

  • PDF

삼중수소 검출용 광섬유 방사선 센서의 제작 및 특성분석 (Fabrication and Characterization of a Fiber-optic Radiation Sensor for Detection of Tritium)

  • 장경원;조동현;유욱재;이봉수;문주현;박병기;조영호;김신
    • 한국광학회지
    • /
    • 제20권4호
    • /
    • pp.201-206
    • /
    • 2009
  • 본 연구에서는 무기섬광체와 광섬유를 이용하여 삼중수소 검출용 광섬유 방사선 센서를 제작하였다. 무기섬광체 선택을 위해 $Gd_2O_2S$ : Tb, $Y_3Al_5O_{12}$ : Ce, CsI : Tl을 이용하여 센서팁을 제작한 후, 금속 수소화물 형태의 삼중수소를 이용하여 섬광효율이 가장 좋은 섬광체를 선별하였다. 또한 선정된 섬광체를 사용하여 제작한 센서를 이용하여 삼중수소 선원으로부터 거리에 따른 섬광량을 계측하였고 선원의 방사능 세기에 따른 섬광량을 측정하여 표면 방사능 모니터의 결과와 비교 분석하였다.

LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발 (Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy)

  • 한기택;유욱재;신상훈;전다영;박장연;박병기;이봉수
    • 센서학회지
    • /
    • 제21권4호
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.