• Title/Summary/Keyword: Inner tap

Search Result 15, Processing Time 0.034 seconds

Development of Low Power Driven Inner Tap Inspection System capable of Wireless Communication with Video Equipment (영상기기와 무선통신이 가능한 저전력 구동의 이너탭 검사시스템 개발)

  • Ahn, Sung-Su
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.649-658
    • /
    • 2018
  • In this paper, we propose a mechanical contact inner tap inspection system that can inspect the defect of the inner tap immediately after inner tap is processed within the machining center. The inspection module has the collet chuck structure, so it can mounted on the main spindle of the machining center during inspection. It was developed with a focus on inspection for tap having 20 mm depth which is primarily fabricated in automotive parts and has a double sided PCB-type control system including sensing function based on Zigbee module, micom and IR sensor for wireless transmission of measured data with low power operation, and also a battery for supplying electric power. The current consumption is 46.8mA in the inspection operation mode and 0.0268mA in the power saving mode for 3.7V of the applied power source, so that 30,000 times or more inspection can be performed with assumed 5 seconds inspection time for one tap. Experiments in test jig system and actual machining center confirm that the proposed inner tap inspection system can be applied to the batch process of simultaneous inspection after tapping in the machining center.

A Study on the Daily life Furniture in Three Kingdoms and Unified Silla Period - Based on the Sang(상) and Tap(탑) - (사료로 본 삼국 및 통일신라시대의 기거용 가구 - 床榻(상탑)을 중심으로-)

  • Lee Jeong-Mee
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.80-88
    • /
    • 2005
  • The ondol is a uniquely Korean system of providing warmth to room. The ondol rooms never use daily life furniture because the ondol warms the floor surface where people sit. Finally, the ondol floor changed the traditional housings inner space. Before use ondol where daily life furnitures[sang(상) and Tap(탑)] are installed in the room. The origin of daily life furnitures are the ancient tomb mural of Koguryo Period. The daily life furniture can be classified as three large groups in the ancient tomb mural of Koguryo. First, a single seat[Jowa-sang(좌상)] of set up a screen[병풍]. The second, It make possible Many peoples take a seat with no decoration seat[Tap(탑)]. The third, uptodately table and chairs. A radical difference between sang(상) and Tap(탑) whether set up a screen[병풍]. The meaning of sang(상) and Tap(탑) in Koguryo ancient tomb provided Oksa-jo[옥사조] in Samkuk-sagi[삼국사기] with several valuable leads to help solve the sang(상)'s meaning. Furthermore, It will be start ponit of study on constructive shape of inner space in those days.

A Study on Flow Rate Characteristics of a $Annubar^{(R)}$ Type Differential Pressure Flow Meter with a Shape Improvement ($Annubar^{(R)}$형 차압유량계 형상 개선에 따른 유량 특성 연구)

  • Oh, Dae-San;Lee, Choong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.2
    • /
    • pp.204-210
    • /
    • 2010
  • The inner structure of the triangular separate bar (TSB) was improved to enhance the productivity of the TSB flow meter by simplifying the machining process for making the flow meter. The cross section of upstream and downstream pressure chamber in the TSB was changed from triangle to circle, which make it possible to substitute the wire cutting by drilling in the process of machining the pressure chamber. The flow rate characteristics of the flow meters was calibrated with a laminar flow meter. Six kinds of flow meters whose diameters of pressure tap for measuring pressure of both upsteam and downstream pressure chamber were different one another were made. The effects of the pressure tap diameter on the flow rate characteristics of the TSB flow meter was little. The mass flow rate characteristics of the flow meters with increasing a non-dimensional parameter which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters and atmospheric pressure shows nearly linear relationship with a correlation coefficient of R=0.998.

Three Level DC/DC Converter Using Energy Recovery Snubber (에너지 회생 스너버를 적용한 3레벨 DC/DC 컨버터)

  • 조용현;김윤호;김은수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.64-73
    • /
    • 2001
  • This paper presents a Zero Voltage and Zero Current Switching (ZVZCS) 3-Level DC/DC converter. This converter overcomes the drawbacks presented by the conventional Zero Voltage Switching(ZVS) 3-Level converter, such as high circulating energy, severe parastic ringing on the rectifier diodes, and limited ZVS load range for the inner switches. The converter presented in this paper uses a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switches. Additionally, the converter uses an energy recovery snubber to reset the primary current during the free-wheeling stage to achieve ZCS for the inner switches. The proposed converters are analyzed and verified on 6kW, 39kHz experimental prototype.

  • PDF

Effects of Cladding and Antifreeze Solution on Cavitation Corrosion of AA3003 Tube of Heat Exchanger for Automobile

  • Young Ran Yoo;Seung Heon Choi;Hyunhak Cho;Young Sik Kim
    • Corrosion Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.203-214
    • /
    • 2024
  • A heat exchanger is a device designed to transfer heat between two or more fluids. In a vehicle's thermal management system, Al heat exchangers play a critical role in controlling and managing heat for efficient and safe operation of the engine and other components. The fluid used to prevent heat exchangers from overheating the engine is mostly tap water. Heat exchange performance can be maintained at sub-zero temperatures using a solution mixed with antifreeze. Although the fluid flowing through the heat exchanger can reduce the temperature inside the engine, it also has various problems such as cavitation corrosion. Cavitation corrosion characteristics in tap water and corrosion characteristics were evaluated in this study when antifreeze was added for test specimens where AA4045 was cladded on the inner surface of AA3003 tubes of a fin-type heat exchanger. The cavitation corrosion resistance of AA3003 was found to be superior to that of AA4045 regardless of the test solution due to higher corrosion resistance and hardness of AA3003 than those of AA4045. The cavitation corrosion rate of Al alloys increased with the addition of antifreeze.

Resistance of Biofilm Bacteria to Chlorination (생물막 세균의 염소소독제에 대한 내성)

  • 조재창;박성주;김상종
    • Korean Journal of Microbiology
    • /
    • v.31 no.3
    • /
    • pp.255-260
    • /
    • 1993
  • The Enterobacter cloacae biofilms developed on slide glasses and galvanized-iron coupons were applied to test the attached bacterial resistance to chlorination. The chlorine resistances of biofilm bacteria grown on the slide glasses and galvanized-iron coupons were 14 and 480 times that of the suspended bacteria, respectively. The chlorine resistance of particleattached bacterial populations was 48 times that of suspended bacterial populations. The biofilm bacterial densities developed on the slide glasses and galvanized-iron coupons which were immersed in the flowing tap water for 75 days were $4.75 {\times} 10^{4}$ and $1.12 {\times} 10^5 cfu/cm^{2}$ It is concluded that main mechanisms of enteric or HPC bacterial resistance to chlorination in tap waters are bacterial attachment or . adsorption to particles or bacterial aggregations and formation of biofilms on the inner wall of distribution systems by escaped bacteria from chlorination in water treatment processes, which results in bacterial regrowth in water distribution systems.

  • PDF

Effect of High Fructose Corn Syrup (HFCS) Intake on the Female Reproductive Organs and Lipid Accumulation in Adult Rats

  • Ko, Eun-Ah;Kim, Hye-Ri;Kim, Yong-Bin;Kim, Hee-Su;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.21 no.2
    • /
    • pp.151-156
    • /
    • 2017
  • High-fructose corn syrup (HFCS) is widely used as sweetener, and its overconsumption is become a major health problem. In the present study, we used adult female rats and applied a 28 days HFCS feeding model to monitor the estrous cycle and changes in tissue weights and histology. Adult female rats were divided into three groups. Animals were fed with ad libitum normal chow and (1) 24 hours tap water (Control group), (2) 12 hours HFCS access during dark period and 12 hours tap water (12H group), and (3) 24 hours HFCS only access (24H group). Total exposure period was 28 days. There is no significant change in body weight between control and HFCS-fed animals. Both absolute and relative weights of ovary in 24H animals were significantly heavier than those in control or 12H animals. The absolute and relative weights of the kidney and liver in 24H groups were significantly heavier than those in control or 12H animals. The estrous cycles of the 24H animals were significantly longer. Histological analyses revealed that 24H ovaries were relatively bigger and possessed more corpus lutea than control ovaries. Uterine sections of 12H and 24H animals showed a well-developed stratum vasculare between inner and outer myometrial layers. The number of endometrial glands were decreased in 12H uteri, and recovered in 24H uteri compared to control. Numbers of convoluted tubule in distal region increased in 12H and 24H kidney samples. Liver specimens of 12H and 24H showed the increased number of fat containing vacuoles. In conclusion, our study demonstrated that HFCS treatment for 28 days could induce (1) changes in length of estrous cycle with extended estrous and diestrous stages, (2) altered ovarian and uterine histology, and (3) liver and renal lipid accumulation. These findings reveal the adverse effects of HFCS drinking on the reproductive function and lipid metabolism of female rats.

Characteristics of Nonthermal Plasma Source in Various Liquids

  • Lim, Seung-Ju;Min, Boo-Ki;Taylor, Nathan;Kim, Tae-Gyu;Kim, Hyeong-Seok;Yang, Seon-Pil;Jung, Jin-Yong;Han, Jin-Hyun;Lee, Jong-Yong;Kang, Seung-Oun;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.259.1-259.1
    • /
    • 2014
  • Recently non-thermal plasma has been frequently applied to various research fields. The liquid plasma have received much attention lately because of interests in surgical and nanomaterial synthesis applications. Especially, intensive researches have been carried out for non-thermal plasma in liquid by using various electrode configurations and power supplies. We have developed a bioplasma source which could be used in a liquid, in which outer insulator has been covered onto the outer electrode. Also we have also put an insulator between the inner and outer electrode. Based on the surface discharge mode, the nonthermal bioplasma has been generated inside a liquid by using an alternating current voltage generator with peak voltage of 12 kV under driving frequency of 22 KHz. Here the discharge voltage and current have been measured for electrical characteristics. Especially, We have measured discharge and optical characteristics under various liquids of deionized (DI) water, tap water, and saline by using monochromator. We have also observed nitric oxide (NO), hydrogen peroxide (H2O2), and hydroxyl (OH) radical species by optical emission spectroscopy during the operation of bioplasma discharge inside various kinds of DI water, tap water, and saline. Here the temperature has been kept to be $40^{\circ}C$ or less when discharge in liquid has been operated in this experiment. Also we have measured plasma temperature by high speed camera image and density by using either H-alpha or H-beta Stark broadening method.

  • PDF

Empirical study on inhibition effect of scale and rust in tap-water line by zinc ionization device (아연 이온화 장치에 의한 상수배관 내 스케일 및 녹 생성 억제효과 실증 연구)

  • Yum, Kyung-Taek;Choi, Jung-Wook;Yang, Sung-Bong;Shim, Hak-Sup;Yu, Mee-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.465-476
    • /
    • 2021
  • Scale and rust generation in water pipes is a common phenomenon when cast iron water pipes have been used for a long time. A physical water treatment device is known among various means for suppressing rust in a water pipe, and a zinc ionization device for putting zinc metal into a pipe and emitting the zinc cation into water is one of such devices. This research measured the amount of zinc ion generated, which is known to exhibit an effect of inhibiting rust and scale generation in a pipe, and examined the scale and rust inhibition effect of the ionization device installed for ground or building water supply. In the case of distilled water, the concentration of zinc ion increased by circulating water in the ionization device several times, and it was verified to be hundreds of ㎍/L, and in the case of discharging ground or tap water, it was verified to be tens of ㎍/L. In addition, a verification pipe was installed to confirm the change inside the pipe before and after installation of the zinc ionization device, and the internal condition of the pipe was observed 3 months to several years after installation. It was confirmed that the corrosion area of the surface of the pipe was no longer increased by installing a corrosion inhibitor, and if the pipe was already filled with corrosion products, the amount of corrosion products gradually decreased every year after installation. The phenomenon of fewer corrosion products could be interpreted as expanding the space in the pipe due to the corrosion product as Fe2O3 adhered to the inner surface of the pipe and turned into a smaller black Fe3O4. In addition, we found that scale such as CaCO3 together in the corrosion by-products gradually decreased with the attachment of the ionization device.