Browse > Article

A Study on Flow Rate Characteristics of a $Annubar^{(R)}$ Type Differential Pressure Flow Meter with a Shape Improvement  

Oh, Dae-San (서울산업대학교 자동차공학과)
Lee, Choong-Hoon (서울산업대학교 자동차학과)
Publication Information
Journal of the Korean Society of Manufacturing Technology Engineers / v.19, no.2, 2010 , pp. 204-210 More about this Journal
Abstract
The inner structure of the triangular separate bar (TSB) was improved to enhance the productivity of the TSB flow meter by simplifying the machining process for making the flow meter. The cross section of upstream and downstream pressure chamber in the TSB was changed from triangle to circle, which make it possible to substitute the wire cutting by drilling in the process of machining the pressure chamber. The flow rate characteristics of the flow meters was calibrated with a laminar flow meter. Six kinds of flow meters whose diameters of pressure tap for measuring pressure of both upsteam and downstream pressure chamber were different one another were made. The effects of the pressure tap diameter on the flow rate characteristics of the TSB flow meter was little. The mass flow rate characteristics of the flow meters with increasing a non-dimensional parameter which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters and atmospheric pressure shows nearly linear relationship with a correlation coefficient of R=0.998.
Keywords
Flow rate; Pressure tap diameter; Differential flow meter; Triangular separate bar; H parameter;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Lee, C. H., Kim, K. I., Kim, M. C., and Park, D. S., 2007, "A Study on Flow Characteristics of a Separate Triangular Bar Differential Pressure Flow Meter for Measuring Exhaust Flow Rate of Diesel Engine," Journal of the Korean Society for Railway, Vol. 9, No. 6, pp. 563-568.   과학기술학회마을
2 ISA 1932 (ISO-5167-3), 2003, Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular-Cross Section Conduits Running Full-Part3:Nozzle and Venturi Nozzle, International Organization for Standardization, Geneva.
3 Baker, R. C., 2000, Flow Measurement Handbook, Cambridge University Press, New York, pp. 427-433.
4 Travoulris,S., 2005, Measurement in Fluid Mechanics, Cambridge University Press, New York, pp. 213-214.
5 Rosemount Product Data Sheet, 1998, Diamond II-$Annubaar^{\circledR}$ bar Primary Flow Element, Dieterich, A Subsidiary of Rosemount Inc.
6 Wayne, W. S., Corrigan, E. R., Atkinson, R. J., Clark, N., and Lyons, D. W., 2001, "Measuring Diesel Emissions with a Split Exhaust Configuration," SAE paper No. 2001-01-1949.
7 Baker, R. C., 2000, Flow Measurement Handbook, Cambridge University Press, New York, pp. 170-171.
8 Britton, C. and Mesnard, D., 1982, "A Performance Survey Round and Diamond-shaped Averaging Pitot Type Primaries," Meas. Control, Vol. 15, pp. 341-350.   DOI
9 Kim, K. I., Yoo, W. Y., and Lee, C. H., 2008, "A Study on Flow Rate Characteristics of a Triangular Separate Bar Differential Pressure Flow Meter according to the Variation of Gas Flow Temperature," Transactions of the Korean Society of Machine Tool Engineers, Vol. 17, No .4, pp. 89-94.   과학기술학회마을
10 Cutler, G. D., 1982, "Averaging Pitot-type Primaries," Meas. Control, Vol. 15, pp. 436-437.