• Title/Summary/Keyword: Inner structure wall

검색결과 122건 처리시간 0.024초

흙주거의 건축적 특성 및 이용현황 분석 (A Study on Architectural Features and Current Status of Earth Housing)

  • 김정규;정주성
    • 한국주거학회논문집
    • /
    • 제17권1호
    • /
    • pp.97-105
    • /
    • 2006
  • The purposes of this study are to find out the current status and features of earth housing, and to explore users' level of satisfaction and needs of improvement about earth housing. Primary findings are as follows: (1) The area of earth housing is generally 25-34 pyong and the construction cost of earth housing is usually 3,000,000-3,400,000 won per pyong. (2) The age of earth house users is generally forties, fifties, and sixties. And their occupation is usually retiree and farmer. The age of earth based pension users is generally twenties and thirties. (3) The construction method of earth housing is usually earth brick structure reinforced with wood structure and earth brick structure(adobe). (4) The finish of outer wall is generally earth brick laying and earth plaster. And the finish of inner wall is usually wall paper and earth plaster. Roof tile and asphalt shingle is frequently observed as roof finish. (5) Users' satisfaction about earth housing is investigated high level. Especially, the satisfaction degrees about faculty of humidity control, stink elimination, prevention from sick house syndrome, support for psychological stabilization and deep sleep are observed very highly. (6) Reduction of construction cost and prevention of crack is investigated as needs of improvement about earth housing.

다구찌 실험계획법을 이용한 소구경화기 총열 내부용 Cr-Mo-V강의 질화공정 최적화 (Optimization of Inner Nitriding Process for Cr-Mo-V Steel of Small Arms Barrel by using Taguchi Experimental Design Method)

  • 권혁린;김동은;손형동;신재원;박재하;강명창
    • 한국기계가공학회지
    • /
    • 제17권3호
    • /
    • pp.148-154
    • /
    • 2018
  • When shooting small arms, the inner surface temperature is heated up to about $700{\sim}1,000^{\circ}C$ by the friction of the bullet and the inner wall of the barrel and the combustion of propellant. High-temperature propellant gas and high-speed movement of the bullet cause corrosion of the inner wall, which is noticeable immediately in front of the chamber. In this study, the mechanical properties of Cr-Mo-V steel, which is the base material, were tested using Taguchi experimental design to find the best nitriding treatment conditions. For the nitriding process, the working time, salt bath temperature, and salt concentration were combined as three conditions and placed in the $L_9(3^4)$, orthogonal array table. The thicknesses of the white layer and the nitrogen diffusion layer were measured after nitriding under each condition in a salt bath furnace. Durability was evaluated by measuring the degree of dispersion through actual shooting because it was difficult to evaluate the mechanical properties of the cylinder inner structure. As a result, it was confirmed that the durability was optimal at $565^{\circ}C$, 1 hour, 0.5%. These optimal conditions were selected by the statistical analysis of the Minitab program(ver.17).

난접근 영역에서의 유동구조 (A Study on the Flow Structures in the Narrow Region)

  • 이강덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.570-575
    • /
    • 2008
  • Flows are studied to understand the flow structure in the narrow region that any experimental approaches are hard to access, Effects on the vehicle commodities from the flows are anticipated in the point of aerodynamics and aero-acoustics. PowerFLOW, which was well validated commercial software, was used to simulate the flow field in the small region, for example, the inner region of the fender panel, the inner region around the front door and the inner region of the trunk lid. Flows in the narrow region could be origins of door sealing problem and dust piling problem.

  • PDF

Optimal Inner Case Design for Refrigerator by Utilizing Artificial Neural Networks and Genetic Algorithm

  • Zhai, Jianguang;Cho, Jong-Rae;Roh, Min-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권7호
    • /
    • pp.971-980
    • /
    • 2010
  • In this paper, an artificial neural network (ANN) was employed to build a predicting model for refrigerator structure. The predicting model includes three input variables of the plaque depth (D), width (W) and interval distance(S) on the inner wall. Finite element method was utilized to obtain the data, which would be necessary for the ANN training process. Finally, a genetic algorithm (GA) was applied to find the optimal parameters that leaded to the minimum inner case deformation under operating condition. The optimal combination found is the depth(D) of 2.63mm, the width(W) of 19.24mm and the interval distance(S) of 49.38mm which leaded to the smallest deformation of 1.88mm for the given refrigerator model.

전도성 원형관 내에 안정화된 예혼합 화염의 구조와 경계 조건에 관한 이론해석 (An Analytical Study on The Structure and Boundary Conditions of The Premixed Flame Stabilized in Conductive Cylindrical Tubes)

  • 김남일
    • 한국연소학회지
    • /
    • 제11권3호
    • /
    • pp.8-17
    • /
    • 2006
  • When a flame is stabilized in a tube of a finite thickness, a conductive heat transfer through the tube significantly changes the wall temperature and affects the flame characteristics. Thus the tube length and thermal boundary conditions affect on the structure of the flame in a conductive tube. A one-dimensional analytical study was conducted by employing two energy equations for tubes and mixtures and a species equation for the mixture. Variation of the maximum temperatures and indicating displacements were observed. A parametric study on the effects of inner Peclet numbers, normalized wall conductivities, and heat transfer conditions of the tube was conducted. This study provides essential data for a more efficient computational simulation of the flame stabilized in conductive tubes.

  • PDF

Rheological Analysis in a Spinning Process of a hollow fiber membrane

  • Jang, Moon-Seog
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 추계 총회 및 학술발표회
    • /
    • pp.5-9
    • /
    • 1995
  • In the dry-jet-wet-spinning process of a hollow fiber membrane, the polymer solution is pumped into a coaxial tube, jet spinneret. The threadline emerging from the spinneret is stabilized by an internal coagulating medium(liquid or gas) as it emerges from the jet orifice. The nascent hollow thread is further stabilized in a quench bath as shown in Fig. 1. In this scheme, three mechanism of formatiota(temperature gradient, solvent evaporation, and solvent-nonsotvent exchange) can be combined. The changes which promote stabilization often play a dominant role in determining the ultimate fiber wall structure as well. Hence, in pratice, hollow fiber stabilization and development of membrane structure are commonly inseparable. However, fiber dimension(the inside diameter and wall thickness of the hollow fiber) is mainly a rheological problem and is determined by dope pumping rate, spinneret diatance from the coagulation bath, inner coagulant flow rate, and fiber draw-rate. Besides rheological phenomena play a prominent part in the final properties of the hollow fiber.

  • PDF

지하 구조물에 적용되는 역타설용 방수시트재의 성능 평가에 관한 연구 (A study on waterproofing method using waterproofing sheet Top-Down method in underground structure)

  • 송제영;곽규성;김정일;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.301-304
    • /
    • 2005
  • The waterproofing in slab and wall of underground structure, have a couple of construction methods which are inside waterproofing methods for inner surface, and outside waterproofing methods for out wall and slab surface waterproofing. In resent years, however, it has been adapted the inside waterproofing construction method, as increasing of construction expenses cost and low workability and technology, nevertheless, outside waterproofing has set a most high value construction method. In inside waterproofing construction method, it is difficult to repair and assure durability and safety for concrete which has direct water-press. So, It is necessary for adopt the outside waterproofing method.

  • PDF

막대형 표면조도가 난류경계층에 미치는 영향 (Effects of Rod-roughened Wall on a Turbulent Boundary Layer)

  • 이승현;김정훈;도덕희;성형진
    • 대한기계학회논문집B
    • /
    • 제32권7호
    • /
    • pp.518-528
    • /
    • 2008
  • The effects of surface roughness on a turbulent boundary layer (TBL) were investigated using particle image velocimetry (PIV). The roughness elements used were periodically arranged two-dimensional spanwise rods, and the roughness height was ${\kappa}/{\delta}$. Introduction of the roughness elements increased the wake strength and the turbulent stress not only in the roughness sublayer but also in the outer layer. This indicates the existence of interaction between inner and outer layers for 2D rod-roughened wall. Roughness effects on a turbulence structure near the wall were obtained by PIV measurements. Iso-contours of mean velocities and Reynolds stresses in the roughness sublayer showed a very good agreement with previous DNS results.

태봉 철원도성의 고지형과 구조 분석 연구 (A Study on the Paleotopographic and Structural Analyses of Cherwon Castle in Taebong)

  • 허의행;양정석
    • 헤리티지:역사와 과학
    • /
    • 제54권2호
    • /
    • pp.38-55
    • /
    • 2021
  • 태봉 철원도성은 현실적 접근의 어려움으로 인해 조사와 연구에 제약이 있다. 따라서 현재 고고학계에서 이용되고 있는 고지형분석 방법론의 적용과 해석을 통해 도성의 구조와 내부 공간 구획의 여러 모습을 파악하였다. 태봉 철원도성은 외성의 북쪽 구릉지성 지형에서 시작하여 남서방향으로 흘러 내려온 다섯 줄기의 평탄한 구릉지형을 이용하여 축조하였다. 내·외성벽은 각 구릉의 능선 줄기를 중심으로, 궁성벽은 그러한 능선 줄기의 중심 구릉지에 축조하였다. 각 성벽에는 여러 방향의 성문과 문지 등이 확인되는데, 도성 내부 건물의 방향과 지형 형태에 맞추어 설치한 것으로 파악된다. 도성 내 궁성은 평면 사다리꼴의 형태이며, 그 내부에는 궁전지와 관련 건물지 그리고 배수관련 지형 등이 확인된다. 궁전의 동서방향으로는 추정 도로와 함께 성문의 위치도 확인되었다. 궁성과 내성의 공간은 각각의 구릉 지형에 맞추어 평탄대지를 조성하고 건물지를 배치하였다. 내성의 남쪽에는 연못지로 추정되는 저수지가 궁성에서 내성의 중심을 잇는 수직 선상에 자리하는 모습이다. 내성과 외성 사이에는 건물지 흔적은 잘 관찰되지 않지만 평탄한 대지 지형의 존재로 그 가능성을 파악할 수 있다. 태봉 철원도성의 전체적인 구조는 북동 방향으로 약 9도 치우쳐 평면 장방형의 형태를 띠고 있다. 구릉성 지형의 형태를 따라 설계하였던 것으로 보이며, 남서벽의 꺽임 현상 또한 습지성 지형을 회피를 의도한 것으로 파악된다. 아직 도성 내부의 건물지 기능과 성격이 불명확하여 이를 바탕으로 한 공간 활용의 모습도 분명치 않다. 하지만 내성은 궁전과 함께 관아 건물지로서의 이용 공간으로서, 외성과 내성 사이 공간은 일반민의 생활 공간으로서 구분되었을 것으로 추정된다. 방리제로서의 구획 흔적도 구릉성 지형의 존재로 인해 그 가능성은 낮아 보이지만, 일부 지형은 평탄한 지대가 넓게 확인되고 있어 정연한 공간 구획의 모습을 배제할 수는 없다. 각 성벽의 축조 선후 시기나 방식 등도 아직 명확치 않지만, 적어도 지형을 이용한 도성의 축조와 내부 공간 구조의 활용을 이해할 수 있다.

냉방에너지 저감을 위한 PCM적용 축열벽 시스템 연구 (Study on PCM Applied Thermal Storage Wall System to Reduce Cooling Energy)

  • 이규영;류리;서장후;김용성
    • 설비공학논문집
    • /
    • 제26권6호
    • /
    • pp.247-256
    • /
    • 2014
  • The regulations to reduce energy consumption and carbon dioxide emission in building sectors are being developed and promoted all over the world. However, in Korea, as balcony extension of the apartments has been legally allowed, it became prevalent and resulted in excessive energy consumption. This study derived the possibility of PCM application to the thermal storage wall system through theoretical consideration and investigated the problems occurring when the balcony space has been extended to the diverted space. In addition, this study aims at the possibility of verifying the installation and confirming the cooling energy reduction effect, by conducting measuring tests with the actual installation of PCM applied thermal storage wall system. As a result of theoretical consideration, it is determined that the disadvantages with the existing thermal storage wall system can be complemented by applying PCM, and this study suggests the PCM applied Thermal Storage Wall System. The study was conducted on 1/6 of a miniature inner room of a domestic apartment with 84 $m^2$ of exclusive area. From the results of actual measurements, it is confirmed that the balcony extension structure can gain 11.3% of more calories than the existing balcony structure, resulting in the increase in cooling energy usage. It is determined that the installation of the PCM applied Thermal Storage Wall System may gain 25.2% of less calories to reduce cooling energy usage.