• Title/Summary/Keyword: Inner current loop control

Search Result 95, Processing Time 0.023 seconds

Dual-Loop Power Control for Single-Phase Grid-Connected Converters with LCL Filter

  • Peng, Shuangjian;Luo, An;Chen, Yandong;Lv, Zhipeng
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.456-463
    • /
    • 2011
  • Grid-connected converters have widely adopted LCL filters to acquire high harmonic suppression. However, the LCL filter increases the system order so that the design of the system stability would be complicated. Recently, sole-loop control strategies have been used for grid-connected converters with L or LC filters. But if the sole-loop control is directly transplanted to grid-connected converters with LCL filters, the systems may be unstable. This paper presents a novel dual-loop power control strategy composed of a power outer loop and a current inner loop. The outer loop regulates the grid-connected power. The inner loop improves the system stability margin and suppresses the resonant peak caused by the LCL filter. To obtain the control variables, a single-phase current detection is proposed based on PQ theory. The system transfer function is derived in detail and the influence of control gains on the system stability is analyzed with the root locus. Simulation and experimental results demonstrate the feasibility of the proposed control.

Analysis of Parameter Effects on the Small-Signal Dynamics of Buck Converters with Average Current Mode Control

  • Li, Ruqi;O'Brien, Tony;Lee, John;Beecroft, John;Hwang, Kenny
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.399-409
    • /
    • 2012
  • In DC-DC Buck converters with average current mode control, the current loop compensator provides additional design freedom to enhance the converter current loop performance. On the other hand, the current loop circuit elements append substantial amount of complexity to not only the inner current loop but also the outer voltage loop, which makes it demanding to quantify circuit and operating parameter effects on the small-signal dynamics of such converters. Despite the difficulty, it is shown in this paper that parameter effects can be analyzed satisfactorily by using an existing small-signal model in conjunction with a newly proposed simplified alternative. As a result of the study, new insight into average current mode control is uncovered and discussed quantitatively. Measurable experimental results on a prototype averaged-current-mode-controlled Buck converter are provided to facilitate the analytical study with good correlation.

The Sinusoidal Ministep Drive Technique

  • Ukakimaparn, P.;Pongswatd, V.;Kummool, S.;Sriratana. W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.466-466
    • /
    • 2000
  • This paper presents the sinusoidal current ministep technique to drive stepping motor. The stepping motor is coupling to the increment encoder to detect the position and speed of the stepping motor. The data from the encoder is decoded to sine and cosine signal and fed to the driver system. The driver system has two loops control, the inner loop and the outer loop. The inner loop is used to control the rotating of the stepping motor and the outer is used to control the speed of the motor. The rotating of the stepping motor is controlled with the sinusoidal signal. The test results of the inner loop control can control the revolution of the stepping motor is smooth and continuously with similar to the DC motor. The outer loop uses to control the speed of the stepping motor with control the DC voltages apply to the driver. The DC voltages that apply to the driver is controlled by the AC-DC converter The test results of the outer loop control, it can control the speed of motor which is provide the any load in the design.

  • PDF

Performance Comparison of Different Solar Array Simulator Control by Ellipse Approximation (태양광패널 모사장치의 제어방식에 따른 소신호 특성 비교 분석)

  • Wellawatta, Thusitha;Seo, Young-Tae;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.16-24
    • /
    • 2021
  • Solar array simulator (SAS) is essential equipment in testing and evaluating the power processing performance of a power conditioning system. However, the nonlinearity in the current(I)-voltage(V) characteristic makes the control loop design of SAS a challenging task. Conventionally, only the inner loop is usually considered in the control design approach. However, this study proves that the reference generation loop also interacts with the inner loop and plays a key role in the overall performance of the SAS. In this paper, the performance of voltage-mode control and impedance control, which are two of the most popular architectures for the SAS system, are reviewed and compared by multi-loop analysis.

Analysis of Stability and Dynamic Behaviour of Ultra Lift Luo Converter

  • Raji, J.;Kamaraj, V.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1970-1979
    • /
    • 2017
  • Ultra Lift Luo Converter (ULC) gained considerable research interest in recent years. The stability analysis of voltage mode and peak current mode controlled ULC in continuous conduction mode is analyzed in this paper. The Eigen value theory is used for the stability analysis of voltage mode controlled ULC. Then to characterize the dynamics of inner current loop, the expressions of closed loop transfer function and loop gain are determined. An algorithm has been developed to analyze the stability of the peak current mode controlled ULC. The theoretical results are correlated with the simulation results obtained using PSIM 9.1(SMARTCTRL 1.0) software. Finally it is proposed to fabricate a prototype and validate the performance by suitable experimental setup.

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads (비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계)

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.

Development of Constant Output Power Supply System for Ozonizer (오존발생장치용 정출력 전원장치의 개발)

  • Woo, Jung-In;Woo, Sung-Hoon;Roh, In-Bae;Park, Jee-Ho;Kim, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.113-121
    • /
    • 2005
  • In this paper, a constant output power supply system for ozonizer is proposed to remove the noise of ozonizer and control the output of ozonizer using feedback control. The proposed system is based on the rouble control loop such as the outer voltage control loop and inner current control loop. In the proposed system overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the experimental results.

Development of Digital Controller and Monitoring System for UPS Inverter (UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발)

  • Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

A Design of Battery Charger using Phase-Lock technique (Phase-Lock 기법을 이용한 Battery 충전기 설계)

  • Song, Eui-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.456-458
    • /
    • 1997
  • The phase-lock technique is applied to a three-phase semi-bridge type battery charger system. Using an inner fast dynamic loop, the phase-locked voltage control (PLVC) technique of three-phase semi-bridge converter is proposed to give a frequency synchronism and to reduce the subharmonics due to the unbalance of transformer or power line. To protect the power devices, the two stage soft-start, function with softly locking the phase and softly increasing the current is presented. As limiting the reference voltage of the inner voltage control loop, muti-lock phenomena are removed on the PLVC loop. A current limit function is also proposed to limit the current of battery and converter. The proposed controller is confirmed through experiment results.

  • PDF