• Title/Summary/Keyword: Inner Wall

Search Result 700, Processing Time 0.032 seconds

Effect of Number of Rough Walls on Heat Transfer in the Square Channel with a Uniform Heat Flux (일정 열유속을 가진 사각채널에서 거친 벽면의 수가 열전달에 미치는 효과)

  • Bae, S.T.;Kim, M.H.;Lee, D.H.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.30-35
    • /
    • 2005
  • Repeated ribs are used on heat exchanger surfaces to promote turbulence and to enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concerns detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue was tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall had a $45^{\circ}$ inclined square rib. Uniform heat flux was maintained on the whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increased with increasing the number of rough walls.

  • PDF

Evaluations of the Acoustics Characteristics of Cellulose Absorbers (셀롤로오즈 흡음재의 음향적 특성 평가)

  • Yeon, Joon-oh;Kim, Kyoung-woo;Yang, Kwan-seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.760-765
    • /
    • 2013
  • Eco-friendly material applied to building would be one of the materials which is must developed for global environmental conservation and reduction of carbon dioxide. For development of eco-friendly material, a cellulose sound-absorbing material has been developed with waste paper through adjustment of various mix proportions. The developed cellulose sound-absorbing material has been tested for its acoustic properties such as acoustic absorptivity and dynamic elastic modulus. The absorptivity was evaluated by developing six samples and using impedance tube and reverberation chamber. As a result of the evaluation, 0.64(NRC) was secured in absorptivity and $4.7MN/m^3$ was indicated in dynamic elastic modulus. Also, for practical use of developed sound-absorbing material as inner heartwood in drywall, comparison test of sound reduction index was performed with existing glass wool sound-absorbing material and constructed drywall of gybsum board. The results have shown 55dB(Rw) of sound reduction index in glass-wool wall and 46dB(Rw) in cellulose.

  • PDF

Evaluations of the Acoustics Characteristics of Cellulose Absorbers (셀룰로오즈 흡음재의 음향적 특성 평가)

  • Yeon, Joon-Oh;Kim, Kyoung-Woo;Yang, Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.456-462
    • /
    • 2013
  • Eco-friendly material applied to building would be one of the materials which is must developed for global environmental conservation and reduction of carbon dioxide. For development of eco-friendly material, a cellulose absorber has been developed with waste paper through adjustment of various mix proportions. The developed cellulose absorber has been tested for its acoustic properties such as absorption coefficient and dynamic stiffness. The absorption coefficient was evaluated by developing six samples and using impedance tube and reverberation chamber. As a result of the evaluation, 0.64(NRC) was secured in absorption coefficient and 4.7 $MN/m^3$ was indicated in dynamic stiffness. Also, for practical use of developed absorbers as inner heartwood in drywall, comparison test of sound reduction index was performed with existing glass wool absorbers and constructed drywall of gypsum board. The results have shown 55 dB(Rw) of sound reduction index in glass-wool wall and 46 dB(Rw) in cellulose.

Pelvic Hydatidosis Mimicking a Malignant Multicystic Ovarian Tumor

  • Singh, Prem;Mushtaq, Deeba;Verma, Neetu;Mahajan, N.C.
    • Parasites, Hosts and Diseases
    • /
    • v.48 no.3
    • /
    • pp.263-265
    • /
    • 2010
  • Echinococcosis is a multisystem disease and has propensity to involve any organ, an unusual anatomical site, and can mimic any disease process. Primary peritoneal echinococcosis is known to occur secondary to hepatic involvement but occasional cases of primary peritoneal hydatid disease including pelvic involvement have also been reported. We report here 1 such case of primary pelvic hydatidosis mimicking a malignant multicystic ovarian tumor where there was no evidence of involvement of the liver or spleen. Our patient, a 27-year-old female, was detected to have a large right cystic adnexal mass on per vaginal examination which was confirmed by ultrasonography. Her biochemical parameters were normal and CA-125 levels, though mildly raised, were below the cut off point. She underwent surgery and on exploratory laparotomy, another cystic mass was found attached to the mesentery of the small gut. The resected cysts were processed histopathologically. On cut sections both large cysts revealed numerous daughter cysts. Microscopic examination of fluid from the cysts revealed free scolices with hooklets and the cyst wall had a typical laminated membrane with inner germinal layer containing degenerated protoplasmic mass. The diagnosis of pelvic hydatid disease was confirmed and patient was managed accordingly. Hydatid disease must be considered while making the differential diagnosis of pelvic cystic masses, especially in endemic areas.

Microparticle Separator based on Dean Vortex in Spiral Microchannel (나선형 미세채널 내부에 형성되는 딘와류 이용한 미세입자 분리소자)

  • Byun, Kang Il;Kim, Hyung Jin;Kim, Byeong Hee;Seo, Young Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.555-560
    • /
    • 2014
  • This paper presents a microparticle separator using a spiral microchannel. A particle separator based on the dean vortex was designed, fabricated, and characterized. Two different spiral microchannels were fabricated. Width and initial radius of rotation in the spiral microchannel were fixed to $300{\mu}m$ and 1.75 mm, respectively. Two different depths of the microchannels were designed at $50{\mu}m$ and $80{\mu}m$. In this experimental study, the equilibrium position of microparticles was monitored by using fluorescent microbeads. In the case of a low dean number (<1.0), lift force and dean drag force were similar, indicating that microbeads were distributed to almost all areas across microchannels. However, in the case of a high dean number (>1.0), dean drag force rather than lift force was dominant, indicating that microbeads moved toward the inner wall of the spiral microchannel.

Comparison of Thermal Comfort Performance Indices for Cooling Loads in the Lecture Room - An Correlation of PMV Bnd EDT - (강의실에서의 냉방부하에 따른 열쾌적성 평가지표 비교 - PMV와 EDT의 연관성 -)

  • Noh Kwang-Chul;Oh Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.868-877
    • /
    • 2005
  • We performed the experimental and the numerical study on the comparison of thermal comfort performance indices for cooling loads in the lecture room for 4 cases: Fan coil unit(FCU) or 4-way cassette air-conditioner is respectively operated with the ventilation system or without. We measured the velocity, the temperature distribution and predicted mean vote(PMV) value in the lecture room for 4 different air-conditioning methods. Effective draft temperature(EDT) and PMV were investigated to analyze the characteristics of two thermal comfort indices in the lecture room and to compare their values each other. From the results we knew that there is the similarity between PMV values and EDTs when the room is air-conditioned for cooling loads. It turned out that definition of the control temperature is very important when the EDT is calculated. Finally EDT should not be used to predict the accurate thermal comfort in case that the temperature and humidity are suddenly varied and the zone affected by the solar and inner wall radiation.

Detection of Lawsonia intracellularis in swine feces by polymerase chain reaction (돼지분변에서 PCR에 의한 Lawsonia intracellularis 검색)

  • 장성준;김정화;김영태;김기향;김중규;김영욱;최일영
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.1
    • /
    • pp.43-50
    • /
    • 2001
  • Swine proliferative enteritis(SPE) caused by inかsoma intracellularis is a common enteric disaese of grower and finisher pig. Swine affected with SPE show variable clinical signs including diarrhea, weight loss, aberrant growth and death. The characteristic lesion of ileitis at necropsy is marked thickening of the last section of the small intestine. The inner lining of the thickened intestine proliferates almost like a cancer and curved rod bacteria(L intracellularis) are always seen inside the intestinal wall. Infected swine shed the organism in the feces. Isolation and growth of pure L intracellularis in vitro requires a suitable cell culture. This procedure is difficult and not a practical means of diagnosis, thus the polymerase chain reaction(PCR) test of feces can be used to determine whether a pig is shedding the infective organism. A sensitive assay based on amplification of a 319bp DffA fragment of the L intracellularis of Swine proliferative enteritis was attempted for the detection of the organism in the 62 feces of swine. L intracellularis was identified on three herds and detected in 6 fecal samples, representing a infection rate of 9.7%. The PCR was very sensitive and specific on the individual level. The PCR technique could be very useful for the diagnosis of this disease.

  • PDF

Clinical Experience of Pectus Excavatum Corrected by Ravitch Method (Ravitch 술식으로 교정한 누두흉 치험)

  • 김하늘루;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.930-934
    • /
    • 1999
  • Background: The purpose of this study is to analyze the clinical results ad operative compatability by Ravitch methods with pectus excavatum. Material and Method: From 1984 to 1997, were performed Ravitch operations in 40 patients of pectus excavatum and analyzed the effects of correction and postoperative complication according to time of operation retrospectively. The group comprised 35 mem and women whose mean age was 8.9$\pm$7.9 years(between 2 to 35 years). All patients had corrected with Ravitch operation or its modified operation. Modified fixations were accomplished with K-wire in 15 patients and internal plate in 2 and the materials were removed 3 months after operation. The result of correction was estimated with the degree of changed distance between inner surface of sternal body and vertebral in 3 months after correction. Result: Postoperative complications were wound disruption in 14 patients. Estimated distances after correction ranged 0.4 cm to 4 cm. The acceptability for chest wall correction was high(6 excellent, 29 good in criteria of Humphreys). Conclusion: We concluded that the benefits of Ravitch operation were a high acceptability of patients and their family, and sufficient correction with no specific complications related operation.

  • PDF

Design of a Heat Exchanger to Reduce the Exhaust Temperature in a Spark-Ignition Engine (가솔린 엔진에서 배기 온도 저감을 위한 열교환기 설계 최적화)

  • Lee, Seok-Hwan;Park, Jung-Seo;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.10-17
    • /
    • 2007
  • Design of experiments (DOE) technique has been used to design an exhaust heat exchanger to reduce the exhaust gas temperature under high load conditions in a spark-ignition engine. The DOE evaluates the influence and the interaction of a selected eight design parameters of the heat exchanger affecting the cooling performance of the exhaust gas through a limited number of experiments. The heat exchanger was installed between the exhaust manifold and the inlet of the close-coupled catalytic converter (CCC) to reduce thermal aging. To maximize the heat transfer between exhaust gas and coolant, fins were implemented at the inner surface of the heat exchanger. The design parameters consist of the fin geometry (length, thickness, arrangement, and number of fin), coolant direction, heat exchanger wall thickness, and the length of the heat exchanger. The acceptable range of each design parameter is discussed by analyzing the DOE results.

Expansion of Multi-wall Carbon Nanotubes and its Lithium Storage Property

  • Ahn, Jung-Ho;Ahn, Jeong-Seok
    • Journal of Powder Materials
    • /
    • v.24 no.4
    • /
    • pp.275-278
    • /
    • 2017
  • In the present work, we apply a technique that has been used for the expansion of graphite to multiwall carbon nanotubes (MWCNT). The nanotubes are rapidly heated for a short duration, followed by immersion in acid solution, so that they undergo expansion. The diameter of the expanded CNTs is 5-10 times larger than that of the as-received nanotubes. This results in considerable swelling of the CNTs and opening of the tube tips, which may facilitate the accessibility of lithium ions into the inner holes and the interstices between the nanotube walls. The Li-ion storage capacity of the expanded nanotubes is measured by using the material as an anode in Li-ion cells. The result show that the discharge capacity of the expanded nanotubes in the first cycle is as high as 2,160 mAh/g, which is about 28% higher than that of the un-treated MWCNT anode. However, the charge/discharge capacity quickly drops in subsequent cycles and finally reaches equilibrium values of ~370 mAh/g. This is possibly due to the destruction of the lattice structures by repeated intercalation of Li ions.