• 제목/요약/키워드: Inner Cavity

검색결과 168건 처리시간 0.028초

Combined treatment of surgery and sclerotherapy for sinus pericranii

  • Ryu, Jeong Yeop;Lee, Jong Ho;Lee, Joon Seok;Lee, Jeong Woo;Lee, Seok Jong;Lee, Jong Min;Lee, Sang Yub;Huh, Seung;Kim, Ji Yoon;Hwang, Sung Kyoo;Chung, Ho Yun
    • 대한두개안면성형외과학회지
    • /
    • 제21권2호
    • /
    • pp.109-113
    • /
    • 2020
  • Sinus pericranii is a rare vascular anomaly characterized by abnormal venous communication between the inner and outer regions of the cranial cavity. Here, we report a case of sinus pericranii and venous malformations in the right periorbital region of a 2-year-old girl. Radiologic findings showed venous malformations in the right parietal region communicating with the superior sagittal sinus in the intracranial region. There were notable improvements following surgical resection for the abnormal venous lesions and several sclerotherapies. Presence of a bluish and pulsating mass on the scalp, which showed bruit on auscultation, may indicate sinus pericranii, which should be included in the differential diagnosis.

납으로 유발된 생쥐 간장 독성에 대한 스쿠알렌의 효과 (Effects of Squalene on the Mice Hepatotoxicity Induced by Lead Acetate)

  • 김종세
    • Applied Microscopy
    • /
    • 제33권3호
    • /
    • pp.205-214
    • /
    • 2003
  • 본 연구의 목적은 스쿠알렌이 납 중독에 대해 효과가 있는 지를 관찰하고자 하였다. 건강한 ICR계 생쥐를 사용하였다. 납을 복강 투여한 후 SOD와 간 조직의 미세구조를 관찰하였다. 실험군은 다음과 같다. Group 1은 납을 복강 투여한 후 스쿠알렌을 처치하지 않은 대조군, Group 2는 납을 복강 투여한 후 스쿠알렌을 처치한 군으로 각 실험군당 생쥐 10마리를 사용하였다. 실험 결과는 다음과 같다. SOD 측정 결과 대조군은 정상군에 비해 수치가 훨씬 낮게 나타났지만, 스쿠알렌을 처치한 군에서는 정상군에 비해 낮지만, 대조군 보다 수치가 높게 나타남을 관찰할 수 있었다(P<0.05). 간 조직의 미세구조에의 경우 납 단독 처치군의 경우사립체의 팽대와 rER은 팽대 및 절단된 상태가 관찰되었으나, 스쿠알렌을 처치한 군에서는 납 단독 처치군에 비해 손상 정도가 덜하였다. 본 연구를 통해 스쿠알렌이 납 중독에 의한 간장 조직의 손상 회복에 대해 효과가 있는 것으로 생각되어진다.

A CONTROLLED CYCLIC LOADING ON THE SURFACE TREATED AND BONDED CERAMIC: STAIRCASE METHOD

  • Yi, Yang-Jin
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.298-306
    • /
    • 2008
  • STATEMENT OF PROBLEM: Effect of surface treatment of ceramic under loading does not appear to have been investigated. PURPOSE: The aim of this study was to investigate the effect of surface treatment of esthetic ceramic, which is performed to increase the bonding strength, on the fracture stress under controlled cyclic loading condition. MATERIAL AND METHODS: Sixty 1.0 mm-thick specimens were made from Mark II Vitablocs (Vita Zahnfabrik, Germany) and divided into 3 groups: polished (control), sandblasted, and etched. Specimens of each group were bonded to a dentin analog material base including micro-channels to facilitate the flow of water to the bonding interface. Bonded ceramics were cyclically loaded with a flat-end piston in the water (500,000 cycles, 15Hz). Following completion of cyclic loading, specimens were examined for subsurface crack formation and subsequent stress was determined and loaded to next specimen by the staircase method according to the crack existence. RESULTS: There were significant differences of mean fatigue limit in the sandblasted (222.86 ${\pm}$ 23.42 N) and etched group (222.86 ${\pm}$ 14.16 N) when compared to polished group (251.43 ${\pm}$ 10.6 N) (P<.05; Wald-type pair-wise comparison and post hoc Bonferroni test). Of cracked specimens, surface treated group showed longer crack propagation after 24 hours. All failures originated from the radial cracking without cone crack. Fracture resistance of this study was very low and comparable to failure load in the oral cavity. CONCLUSION: Well controlled cyclic loading could induce clinically relevant cracks and fracture resistance of Mark II ceramic was relatively low applicable only to anterior restorations. Surface treatment of inner surface of feldspathic porcelain in the matsicatory area could influence lifetime of restorations.

공조용 로터리 압축기 소음저감을 위한 어큐뮬레이터 최적설계 (Design Optimization of an Accumulator for Noise Reduction of Rotary Compressor)

  • 이의윤;김봉준;이정배;성춘모;이운섭;이종수
    • 대한기계학회논문집A
    • /
    • 제35권7호
    • /
    • pp.759-766
    • /
    • 2011
  • 최근 가정용 에어컨은 냉방효율뿐 아니라 소음에 대한 중요성이 지속적으로 높아지고 있다. 로터리 압축기는 에어컨의 소음 중 매우 높은 영향도를 가지고 있으며, 압축기의 소음을 줄이기 위해 머플러 및 공명기에 관한 많은 연구들이 진행되어 왔다. 압축기의 부품 중 어큐뮬레이터는 큰 용적으로 인해 공명에 의한 추가 소음을 에어컨에 전달하는 소음 전달경로가 되며, 어큐뮬레이터의 내부구조는 소음저감을 위해 중요한 설계요소가 되나 지금까지는 연구결과가 미비한 수준이었다. 본 논문에서는 어큐뮬레이터의 소음 저감을 위해 목표주파수 대역에서의 투과손실이 최대가 되는 설계최적화를 수행하였다. 높은 비선형성을 가진 문제의 최적화를 위해 실험계획법과 반경기저신경망기법을 이용한 근사 모델을 사용하였으며, 유전알고리즘을 사용한 최적화를 수행하였다.

Ca 혼합처방인 SG 및 GN이 난소절제 백서의 골다공증에 미치는 영향 연구 (Effects of Herbal Compounds with Tuna bone Powder on Rodent Osteoporosis Model Induced by Ovariectomy)

  • 지규용;윤군애;김영만
    • 동의생리병리학회지
    • /
    • 제17권5호
    • /
    • pp.1281-1287
    • /
    • 2003
  • In this research 2 sample compounds are made and analyzed in terms of the in vivo and in vitro effects on the ovariectomized rats. The 2 compounds are prescribed based on pathologic patterns of osteoporosis, and added calcium citrate from tuna bone powder. SG is for menopausal women(Type I osteoporosis) and GN is for senile men(Type II osteoporosis). Through these, SG manifested Significant effects on the T4, osteocalcin level, and through the histological changes of osteoid tissues and lipocytes. On the other hand GN showed significant increase on the biochemical markers of osteocalcin, TALP, even in histological features and bone mineral density and intensity of femur it showed meaningful changes. But In the results of RT-PCR on the IL-1β, IL-6, TNF α, there weren't coherent results with in vivo test, that is they were increased in the sample compound group than control group. These increase of bone resorption was seemed that those cytokines had the osteoclasts promote their own resorptive functions after fragments of bone tissues were increased in the cavity. And this clearance of inner fragments help the bone to strengthen its own substance. Putting together above facts, the sample compounds, SG and GN, made of tuna bone powder and herbal solutions are predicted that there would be pharmacological actions improving the osteoporosis initiated from the disorders of calcic absorption and increase of bone resorption. And GN has more effective actions than SG at least in the animal model.

양식넙치, Paralichthys olivaceus 치어의 스쿠티카충 감염경로 (Infection Route of Scuticociliates in the Juvenile of the Cultured Flounder, Paralichthys olivaceus)

  • 진창남;이창훈;오상필;나오수;허문수
    • 한국어병학회지
    • /
    • 제16권1호
    • /
    • pp.13-21
    • /
    • 2003
  • The infection characteristics with scuticociliates at on-land rearing farms and hatcheries of flounder, Paralithys olivaceus was investigated during the year of 2001 by juvenile infection routes. When culture tanks for living food organisms such as chlorella, rotifer, and Artemia were searched, scuticocilates were detected both in live and dead rotifer, and at the dregs of culture tank bottoms at almost hatcheries. When rotifer infected with scuticocilates fed on fish larvae, lots of scuticocilate were inhabited at the bottom of fry rearing tanks. After feeding on scuticocilates-infected rotifer on fish larvae, first infection was detected at 10 days after bottom dwelling or 40 days old after hatching. By histopathological examination we confirmed the infection route of eyeball or brain contamination was that the ciliate worms digged through mouth and front part of the dosal fin cuticle, transferred into eyeball along the epithelium and muscle tissue, and reached finally into brain by the muscle and nerve tissue. The infection of internal organs was clarified into two routes. The first route was started from the infection at ventral and anal fin rays by the worms, and reached at the anus and rectum through the epithelium and muscle tissue. The second route was initiated from the infection at urinary organ and reached into the rectum epithelium cells, inner wall of intestine, abdominal cavity, pancreas, kidney, and pancreas. At seed production farms where fish larvae fed on scuticocilate-free rotifer, the worms were not detected not only at the food organisms culture tanks and juvenile rearing tanks but also larval flounder less than 7cm in total length.

Wear, microleakage and plastic deformation of an implant-supported chair-side bar system

  • Mehl, Christian Johannes;Steiner, Martin;Ludwig, Klaus;Kern, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.323-328
    • /
    • 2015
  • PURPOSE. This in-vitro study was designed to evaluate retention forces, microleakage and plastic deformation of a prefabricated 2-implant bar attachment system (SFI-Bar, Cendres+$M{\acute{e}}taux$, Switzerland). MATERIALS AND METHODS. Two SFI implant-adapters were torqued with 35 Ncm into two implant analogues. Before the tube bars were finally sealed, the inner cavity of the tube bar was filled with liquid red dye to evaluate microleakage. As tube bar sealing agents three different materials were used (AGC Cem (AGC, resin based), Cervitec Plus (CP; varnish) and Gapseal (GS; silicone based). Four groups with eight specimens each were tested (GS, GS+AGC, AGC, CP). For cyclic loading, the attachment system was assembled parallel to the female counterparts in a chewing simulator. The mean retention forces of the initial and final ten cycles were statistically evaluated (ANOVA, ${\alpha}{\leq}.05$). RESULTS. All groups showed a significant loss of retention forces. Their means differed between 30-39 N initially and 22-28 N after 50,000 loading cycles. No significant statistical differences could be found between the groups at the beginning (P=.224), at the end (P=.257) or between the loss of retention forces (P=.288). Microleakage occurred initially only in some groups but after 10,000 loading cycles all groups exhibited microleakage. CONCLUSION. Long-term retention forces of the SFI-Bar remained above 20 N which can be considered clinically sufficient. The sealing agents in this study are not suitable to prevent microleakage.

소나 시스템 설계를 위한 FFR 트랜스듀서 어레이의 등가회로 모델링 (Equivalent Circuit Modelling of FFR Transducer Array for Sonar System Design)

  • 김인동;최승수;이학수;이승우;문원규
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.629-635
    • /
    • 2017
  • Free-Flooded Ring (FFR) transducer array for use in Sonar system can be driven with large amplitude in a wide frequency band due to its structural characteristics, in which two resonances of a ring mode (1st radial mode) and an inner cavity vibration mode occur in a low frequency band. Since its sound wave generation characteristics are not influenced by the water pressure, the FFR transducer array is widely used in the deep sea. So FFR has been recognized as a low-frequency active sound source and has received much attention ever since. In order to utilize the FFR transducer array for SONAR systems in military and industrial applications, its equivalent electric circuit model is necessary especially to design the matching circuit between the driving power amplifier and the FFR transducer array. Thus this paper proposes the equivalent electric circuit model of FFR transducer array by using measured values of parameter, and suggest the improved method of parameter identification. Finally it verifies the effectiveness of the proposed circuit model of FFR transducer array by experimental measurements.

논문 : 모따기 된 전향계단에 부딪치는 와류에 의한 유동소음 (Papers : Flow Noise due to the Impinging Vortex to the Chamfered Forward Step)

  • 유기완
    • 한국항공우주학회지
    • /
    • 제30권1호
    • /
    • pp.28-35
    • /
    • 2002
  • 공동흐름에서 직각 계단은 커다란 소음의 원인이 되어 많은 사람들의 와류와 직각계단의 상호 작용 시에 발생되는 소음의 저감 방안을 연구하여 왔다. 본 연구에서는 2차원 저아음속 와류 흐름이 전향계단을 지날 때 발생되는 유동 소음을 전향계단의 형상 변화를 통한, 즉, 계단의 모따기 양과 각도를 바꾸어 가면서 수치적으로 계산하였다. 내부 유동장을 구하기 위해서 비압축성 비점성 이산와류 모델을 가정하였으며, 유동정보로부터 원거리로의 음향장 계산은 MAE 이론을 적용하여 구하였다. 음원에서의 음압과 음압강도를 모따기 높이 및 모따기 각도와 최기 와류의 높이를 변화시켜가면서 다양하게 수치적인 결과를 얻어내었다. 본 연구를 통해서 계단에 접근하는 와류에 의한 원거리 음압은 모따기 양이 계단 높이의 30%에서 모따기 각도가 $15^{\circ}C$에서 $30^{\circ}C$°사이일 때 가장 소음이 적게 발생되는 결과를 얻어내었다.

PCS 대역 세포실험용 전자파 노출 장치 개발 (Development of A Electromagnetic Exposure System for In Vitro Experiments at PCS Band)

  • 박민영;고채옥;성미진;김정란;백정기
    • 한국전자파학회논문지
    • /
    • 제17권4호
    • /
    • pp.335-340
    • /
    • 2006
  • 본 논문에서는 국내 PCS 대역인 1,762.5 MHz의 세포실험용 전자파 노출 장치를 설계 및 제작하였다. 노출 장치는 도파관의 ${\lambda}_g/4$ 지점에 위치한 ${\lambda}_g/8$ 모노폴 안테나에 의해 $TE_{102}$ 모드로 동작되며, 노출 장치 내부에 내부 직경이 8.5 cm인 petri dish 1개를 노출시킬 수 있다. 세포실험용 전자파 노출 장치는 구형 공진기형으로 수치 해석 기법 중 하나인 FDTD 방법을 사용하여 SAR을 해석하였고 온도 프로브(model 790, Luxtron Corp)를 이용해 측정하였다.