Development of Pilot Injection Plant for CO2 Underground Storage (이산화탄소 지중저장용 파일럿 주입플랜트 개발)

  • Yoon, Seok-Ho;Kim, Young;Lee, Jun-Ho;Lee, Kong-Hoon
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.42-45
    • /
    • 2013
  • The worldwide issue of greenhouse gas reduction has recently drawn great attention to carbon capture and storage(CCS). In this study, we developed a 10,000 ton/year pilot injection plant for geological storage of carbon dioxide. Major components of the pilot plant include a pressure pump, a booster pump, and an inline heater to bring liquid carbon dioxide into its supercritical state. The test results show that the pilot plant readily achieves the injection pressure and temperature, showing satisfactory control performance. The overall power consumption is 2,000 ~ 2,500 W, more than 75% of which consumed by the pressure pump. This study will facilitate varied research on greenhouse gas reduction as the only domestically developed system for geological injection.

  • PDF

Shear bond strength in bilayer metal-heat pressed glass ceramic structure (열가압 방식의 금속-유리도재 이중 구조물의 전단결합강도에 대한 연구)

  • Lee, Kyungeun;Park, Jin-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.2
    • /
    • pp.101-107
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the shear bond strength of the metal-heat pressed glass ceramic bilayer structure. Methods: Metal framework specimens were prepared and surface is spreaded opaque(IPS InLine system opaque, IvoclarVivadent, Liechtenstein). There were 10 specimens for each bilayer dental ceramic group. The first group was porcelain fused metal, Press on metal IPS Inline press group, and press on metal HASS prototype group. Specimens measured for the shear bond strength on Schwickerath test by Instron universal testing machine(Instron3345, Instron Corp., USA). Mean average bond strength values of each specimen group were analyzed using a one-way ANOVA analysis of variance Saphiro-wilk's test. Statistical analysis were performed using IBM SPSS 23.0(IBM Co., Armonk, USA) Results: $RMS{\pm}SD$ The highest mean average HASS POM showed a bond strength value ($47.55{\pm}12.80Mpa$). The lowest mean average values Porcelain fused metal ($33.30{\pm}2.00Mpa$). Independent t-test was conduct to analysis the significant difference (p<0.05) (Table 3). Conclusion: Three kinds of Metal/ glass bilayer dental ceramics bond strength were clinical acceptability. Especially, as lithium disilicate containing represents higher bond strength.

Heat/Mass Transfer and Friction Characteristic in a Square Duct with Various Discrete Ribs -In-Lined Gap Arrangement Ribs- (덕트내 요철의 단락위치 변화에 따른 열/물질전달 및 압력강하 특성 - 정렬 단락배열 요철 -)

  • Lee, Sei-Young;Choi, Chung;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1640-1649
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements on heat/mass transfer in the cooling passage of gas turbine blades. A complex flow structure occurs in the cooling passage with rib turbulators which promote heat transfer on the wall. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. A numerical computation is performed using a commercial code to calculate the flow structures and experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. A square channel (50 mm $\times$ 50 mm) with rectangular ribs (4 mm $\times$ 5 mm) is used fur the stationary duct test. The experiments focus on the effects of rib arrangements and gap positions in the discrete ribs on the heat/mass transfer on the duct wall. The rib angle of attack is 60°and the rib-to-rib pitch is 32 mm, that is 8 times of the rib height. With the inclined rib angle of attack (60°), the parallel rib arrangements make a pair of counter rotating secondary flows in the cross section, but the cross rib arrangements make a single large secondary flow including a small secondary vortex. These secondary flow patterns affect significantly the heat/mass transfer on the ribbed wall. The heat/mass transfer in the parallel arrangements is 1.5 ∼2 times higher than that in the cross arrangements. However, the shifted rib arrangements change little the heat/mass transfer from the inline rib arrangements. The gap position in the discrete rib affects significantly the heat/mass transfer because a strong flow acceleration occurs locally through the gap.

The Simulation of Runoff Reduction by the Storage Type of Zermeable Concrete Block Paving on Andong Maskdance Festival Square (저류형 투수블록 설치를 통한 안동국제탈춤광장 유출량 저감효과 모의)

  • Park, Sung Ki;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.293-300
    • /
    • 2018
  • Ihe purpose of this study is to evaluate the effects the storage type of permeable concrete block paving (ST-PCBP) have on runoff reduction and infiltration increasement at Andong Maskdance Festival Square. This was accomplished using the NRCS-curve number method over the last 10 years. Two different scenarios were developed in this study for low impact development (LID) design. For the $1^{st}$ scenario, the walking path and parking lot were install using the ST-PCBP and runoff from the inline skating rink ($3,808m^2$) and lawn ($11,191m^2$) were routed to the ST-PCBP, but the rooftop runoff flowed into the storm water drainage system. For the $2^{nd}$ scenario, one of the non-structural BMPs, disconnected impervious surface (DIS), was applied so additional runoff from rooftop would enter the ST-PCBP. It was determined that ST-PCBP could significantly reduce surface runoff from the study area and increase infiltration with 71% and 88% of surface runoff reduction and 151% and 215% of infiltration increasement for scenarios 1 and 2, respectively. The effect of LID in the $2^{nd}$ scenario was better than the $1^{st}$ scenario, therefore DIS in conjunction with ST-PCBP could be a more cost-effective LID application.

Characteristic Analysis of Eddy Current Array Probe Signal in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis (전자기 수치해석을 이용한 표준보정시험편의 배열형 와전류 탐촉자 신호 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.330-337
    • /
    • 2010
  • In this paper, 3-dimensional electromagnetic numerical analysis is performed about the eddy current(EC) array probe characteristic which is the next generation probe for accurate diagnosis of steam generator(SG) in nuclear power plants(NPPs). ASME(American Society of Mechanical Engineers) Standard and X-probe combo calibration standard tube are selected for acquisition of eddy current testing(ECT) signals and this result of compared with the real test signals for reasonability of result. Based on the analysis result of calibration standard tube, ECT signals that are about the defects of pitting, stress corrosion cracking(SCC), multiple SCC and wear is obtained. Material of specimen was Inconel 600 which is usually used for SG tubes in NPPs. The operation frequency of 300 kHz were used. The signal characteristics could be observed according to the various defects. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

Process Characteristics of Atmospheric Pressure Plasma for Package Substrate Desmear Process (패키지 기판 디스미어 공정의 대기압 플라즈마 처리 특성)

  • Ryu, Sun-Joong
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.5
    • /
    • pp.337-345
    • /
    • 2009
  • When the drill hole diameter for the package substrate is under $100{\mu}m$, the smear in the drill hole cannot be eliminated by wet desmear process only. We intended to change the substrate's hydrophobic characteristics to hydrophilic characteristics by adapting the atmospheric pressure plasma prior to the wet desmear process. Atmospheric pressure plasma process was made as the inline type equipment which is adequate for the package substrate's manufacturing process and remote DBD type electrodes were used for the equipment. As the result of atmospheric pressure plasma processing, the contact angle of the substrate was enhanced from 71 degree to 30 degree. Dielectric film thickness, drill hole diameter and surface roughness were measured to evaluated the characteristics of the wet desmear process in case of plasma processing and in case of none. By the measurement, it was analyzed that the process uniformity within the whole panel was largely enhanced. Also, it was verified that the smear in the drill hole was eliminated efficiently which was analyzed by the SEM image of the drill hole.

Improvement of Emission Performance in a 3.3 Liter DI Diesel Engine by Using Dimethyl Ether Fuel (디메틸에테르 연료를 사용하는 3.3리터 디젤기관의 배기성능 개선)

  • Pyo, Young-Dug;Lee, Young-Jae;Kim, Mun-Heon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.178-185
    • /
    • 2007
  • A study is improvement of power and emission in a inline-pump Dr diesel engine by using Dimethyl ether Fuel. Dimethyl ether (DME) is an oxygenated fuel with a cetane number higher than that of diesel oil. It meets the ULEV emission regulation and reduces the smoke to almost zero when used in a diesel engine. But NOx emission is almost same and CO, THC emissions are lower than that of diesel engine. The emissions aren't satisfied the stronger emission regulation in the further. Generally DOC (Diesel Oxidation Catalyst) is used to reduce CO & THC emissions and EGR (Exhaust Gas Recirculation) system is used to reduce NOx emission. Test results showed that the torque and the power with DME were almost same as those of pure diesel oil, but the brake thermal efficiency increased a little. also the BSEC (Brake Specific Energy Consumption) with DME was similar that of diesel. The test results showed that the DOC was the vary effective method to reduce the CO emission in case of Dimethyl Ether Fuel in diesel engine. But, THC emission is showed a little reduction rates. Also EGR system was the very effective method to reduce the NOx emission in case of Dimethyl Ether Fuel in diesel engine.

Acquisition and Processing of Shallow Vector Seismic Data (천부 탄성파 벡터자료 획득 및 분석)

  • Hong, Myung-Ho;Kim, Ki-Young;Hwang, Yoon-Gu
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.2
    • /
    • pp.81-87
    • /
    • 2005
  • Acquisition and processing of vector seismic waves were conducted through simultaneous generation of P, SH, and SV waves and receiving those waves using three-component geophones. Test data were received by 24 8-Hz geophones at an interval of 2 m along a 94-m profile. The data were recorded for 512 ms with sampling intervals of 0.2 ms. Raw data indicate that both reflected and refracted P waves are strongly recorded on the vertical component while SH waves are significant on the transverse horizontal component. On the inline horizontal component, both direct P and converted PS waves are recorded. First arrivals of P and SH waves were detected simultaneously on the vertical and transverse horizontal axes, respectively. The recorded vector data were separately inverted using traveltime tomography to yield P- and SH-wave sections. Using those two velocity sections, Poisson's ratios were able to be obtained effectively.

  • PDF

Shock Attenuation Mechanism in Drop Landing According to the Backpack Weight Changes (드롭랜딩 시 backpack 중량 변화에 따른 충격 흡수 기전)

  • Choi, Chi-Sun;Nam, Ki-Jeong;Shin, In-Sik;Seo, Jung-Suk;Eun, Seon-Deok;Kim, Suk-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.25-35
    • /
    • 2006
  • The purpose of this study was to investigate the shock attenuation mechanisms while varying the loads in a backpack during drop landing. Ten subjects (age: $22.8{\pm}3.6$, height: $173.5{\pm}4.3$, weight: $70.4{\pm}5.2$) performed drop landing under five varying loads (0, 5kg. 10kg. 20kg. 30kg). By employing two cameras (Sony VX2100) the following kinematic variables (phase time, joint rotational angle and velocity of ankle, knee and hip) were calculated by applying 2D motion analysis. Additional data, i.e. max vertical ground force (VGRF) and acceleration, was acquired by using two AMTI Force plates and a Noraxon Inline Accelerometer Sensor. Through analysing the power spectrum density (PSD), drop landing patterns were classified into four groups and each group was discovered to have a different shock attenuation mechanism. The first pattern that appeared at landing was that the right leg absorbed most of the shock attenuation. The second pattern to appear was that subject quickly transferred the load from the right leg to the left leg as quickly as possible. Thus, this illustrated that two shock attenuation mechanisms occurred during drop landing under varying load conditions.

Experimental Study of VIV Characteristics of Free Hanging PVC Pipe under Forced Oscillation Conditions (강제가진조건에서 자유롭게 매달린 PVC 파이프의 와류유기진동 특성에 관한 시험 연구)

  • Kwon, Yong-Ju;Jung, DongHo;Park, Byeong-Won;Jung, Jae-Hwan;Oh, Seunghoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.341-350
    • /
    • 2018
  • A series of model tests was carried out to investigate the vortex-induced vibration (VIV) characteristics of a free hanging PVC pipe under forced oscillation conditions. The prescribed displacement with a period and amplitude was forced at the top of the riser. The motion of the riser along its length was measured with underwater cameras in three dimensions. The top-excited responses in the inline direction and vortex-induced vibration in the cross-flow direction were examined in the time and frequency domains. Multi-peak frequencies in the VIV were demonstrated to be strongly dependent upon the Keulegan-Carpenter number, corresponding with the results of Blevin. It was found that the Reynolds numbers (excitation period) was a critical parameter for the dominant VIV characteristics, even under the condition of using the same Keulegan-Carpenter number, under the top-excited condition. In the resonance at the nth natural frequency by the forced-motion induced VIV frequency, the riser responded with a large amplitude and forced frequency, dominantly in the VIV CF direction.