• Title/Summary/Keyword: Inlet Screen

Search Result 28, Processing Time 0.021 seconds

A Numerical Study for Optimum Design of Dust Separator Screen Based on Coanda Effect (코안다효과를 이용한 제진기 스크린의 최적설계를 위한 수치적 연구)

  • Yun, Seong-Min;Kim, Yong-Sun;Shin, Hee-Jea;Ko, Sang-Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.177-185
    • /
    • 2018
  • There is a need to study dust separator screens with good drainage efficiency while effectively filtering suspended solids and other contaminants entering the intake pumping station, the drainage pumping station and the mediation pumping station, the cooling water inlet of the power plant, and the like. In this paper, Numerical studies were conducted for the optimal design of the dust separator screen using the Coanda effect. The shape of the dust separator screen is important, such as the right curvature radius $R_1$ at the top of the dust separator screen and the left curvature radius $R_2$ at the top, h is the height difference and shape between the screen and the accelerating plate, and ${\theta}$ is the inclination angle of the screen. A total of 4 shape factors were set and the effects of Coanda and drainage performance of each element were compared and analyzed, the optimum length and size of each shape element were derived by classifying the shape elements into direct and indirect influences. Finally, it was possible to effectively filter foreign matter by narrowing the screen spacing, and the drainage performance was analyzed and optimized through numerical studies of dust separator screen.

Measurement of Surface Heat Transfer Using Exponential Temperature Variations (지수형 온도변화를 이용한 표면 열전달의 측정)

  • Park, Byung Kyu;Hong, Taek;Park, Sang Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1121-1128
    • /
    • 1999
  • A single blow, transient testing method for determining the heat transfer characteristics of heat exchanger surfaces are presented. The exponential inlet temperature variations were made using screen mesh with small time constant and frontal velocities of the test section. The system is used to investigate the usefulness of a model with exponential inlet temperature variations. A data reduction program is developed to calculate the temporally and spatially averaged heat transfer coefficient using the measured disturbance and response of the fluid temperature. The results are compared with the existing theoretical and experimental data for parallel plate stacks. It was recommended to take an average for the time greater than the 99% of the final temperature had reached in order to obtain fairly good results.

Basic Study on the Regenerator of Stilting Engine (II) - Heat transfer and flow friction loss characteristics of the regenerator with wire screen matrix - (스털링기관용 재생기에 관한 기초연구 (II) - 철망을 축열재로 한 재생기의 전열 및 유동손실특성 -)

  • 김태한;이시민;이정택
    • Journal of Biosystems Engineering
    • /
    • v.27 no.6
    • /
    • pp.529-536
    • /
    • 2002
  • The performance of stilting engine, in particular, its energy conversion efficiencies are critically influenced by the regenerator characteristics. The regenerator characteristics are influenced by effectiveness, void fraction. heat transfer loss and fluid friction loss in the regenerator matrix. These factors were influenced by the surface geometry and material properties of the regenerator matrix. The regenerator design goals arc good heat transfer and low pressure drop of working Bas across the regenerator. Various data for designing a wire screen matrix have been given by Kays and London(1984). The mesh number of their experiment. however, was confined below the No. 60. which seems rather small for the Stirling engine applications. In this paper. in order to provide a basic data for the design of regenerator matrix, characteristics of heat transfer and flow friction loss were investigated by a packed mettled of matrix in oscillating flow as the same condition of operation in a Stirling engine. Seven kinds of sing1e wire screen meshes were used as the regenerator matrices. The results are summarized as follows; 1. While the working fluid flew slowly in the regenerator. the temperature difference was great at the both hot-blow(the working fluid flows from healer to cooler) and cold-blow(the working fluid flows from cooler to healer). On the other hand. while the working fluid flew fast. the temperature difference was not distinguished. 2. The No.150 wire screen used as the regenerator matrix showed excellent performance than tile others. 3. Phase angle variation and filling rate affected heat transfer or regenerator matrices. 4. Temperature difference between the inlet and outlet of the regenerator is very hish in degree of 120 phase angle.

Isothermal Characteristics of a Rectangular Parallelepiped Sodium Heat Pipe

  • Boo Joon Hong;Park Soo Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1044-1051
    • /
    • 2005
  • The isothermal characteristics of a rectangular parallelepiped sodium heat pipe were inves­tigated for high-temperature applications. The heat pipes was made of stainless steel of which the dimension was $140\;m\;(L)\;{\times}\;95m\;(W)\;{\times}\;46 m\;(H)$ and the thickness of the container was 5 mm. Both inner surfaces of evaporator and condenser were covered with screen meshes to help spread the liquid state working fluid. To provide additional path for the working fluid, a lattice structure covered with screen mesh wick was inserted in the heat pipe. The bottom surface of the heat pipe was heated by an electric heater and the top surface was cooled by circulating coolant. The concern in this study was to enhance the temperature uniformity at the bottom surface of the heat pipe while an uneven heat source up to 900 W was in contact. The temperature distribution over the bottom surface was monitored at more than twenty six locations. It was found that the operating performance of the sodium heat pipe was critically affected by the inner wall temperature of the condenser region where the working fluid may be changed to a solid phase unless the temperature was higher than its melting point. The maximum temperature difference across the bottom surface was observed to be $114^{\circ}C$ for 850 W thermal load and $100^{\circ}C$ coolant inlet temperature. The effects of fill charge ratio, coolant inlet temperature and operating temperature on thermal performance of heat pipe were analyzed and discussed.

CFD Analysis for Microclimate of Venlo Type Glasshouse with the Screen Height and Air-inflow Quantity (스크린설치높이·공기유입량 차이에 따른 벤로형 유리온실 미기상 CFD 유동해석)

  • Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.52-61
    • /
    • 2020
  • The natural change of winter night temperature from 00:00 to 04:30 O'clock with the different height of thermal screen in a venlo type glasshouse (W59×L68×H5.9 m) was studied using computational fluid dynamics (CFD). At the early stage of CFD analysis, the room temperature decrease of glasshouse with the 5.9 m height of thermal screen were faster than it with the 4.1m height of thermal screen, but at 2 hr after analysis it was slower than in it with the 4,1m, the temperature difference was 0.6℃ after 4 hr. If we consider that turn on the heater when the temperature were decrease below 13℃ at 1hr after CFD analysis, it is good for energy saving in the glasshouse with the 4.1 m height of thermal screen rather than in it with the 5.9 m height, because of the temperature decrease were slow during 2 hrs after analysis. The airflow at the height of 2 m which were grown tomato were fast and wide in the glasshouse with the 5.9 m height thermal screen rather than in it with the 4.1 m, the speed difference was 0.034m·s-1 at 1hr after CFD analysis. The effect of temperature decrease in summer season were compared with the different height of shading screen from 12:00 to 14:30 O'clock. The height of shading screen were 5.7, 3.9 m, the gap of it were 30%. The air-inflow quantity by the fan with duct at lower part of venlo glasshouse was 0.67 ㎥·s-1 until 1hr and to increase 3 times of it from 1hr after analysis. The roof window were open 100%. Until 1hr of CFD analysis, the temperature in the 30% open of shading screen was 0.9℃ higher than in the none shading screen. From 13:00 O'clock when the air-inlet quantity to increase 3 times, the temperature in case 30% gap of shading screen were decreased compare with the none shading screen, the temperature difference was 0.5℃ at 14:30 O'clock. The temperature on the floor surface in case 30% gap of shading screen were lower with it's height increase, the temperature difference was 8℃ compare with none shading screen. The relative humidity difference were insignificant by the height and gap of shading screen.

A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack (악취 배출구의 합리적인 배출규제를 위한 사례연구)

  • Park, Jeong-Ho;Lee, Hyung-Chun
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.155-161
    • /
    • 2016
  • In this study, field experiment, odor simulator, and dispersion modeling were used to evaluate the odor impact from J sewage sludge treatment facility. The height and flow rate of exhaust stack at this facility were 22.3 m and $100Nm^3/min$. The mean odor concentrations of the wet scrubber inlet and exhaust stack were $267{\pm}160$ and $93{\pm}44OU/m^3$, respectively. The odor removal efficiency of wet scrubber showed 65%. The odor simulator is used for the regulated standard calculation of the exhaust pipe(stack). Resulting odor emission rate(OER) by odor simulator was $2.4{\times}10^6(24,000OU/m^3)$. The forecasting result by Screen3 modeling showed that odor exhaust concentration up to $30,000OU/m^3$ was't exceeded maximum allowable emission level on site boundary($15OU/m^3$).

The Development of Filter for Environmental Improvement in Land Based Seawater Fish Farm II. Purification efficacy of Inlet and Outlet Seawater by Filter (필터의 개발을 통한 해수 육상수조식 양식장의 환경개선에 관한 연구 II. 필터 운행에 따른 유입수 및 배출수의 정화효과)

  • KANG Ju-Chan;PARK Soo-Il;KIM Seoung-Gun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.6
    • /
    • pp.914-919
    • /
    • 1998
  • This study was conducted to evaluate the purification efficacy by filter and ultra violet (UV) irradiation against inlet and outlet seawater of the land based fish farm. Purification efficacies for inlet seawater (50$\ell$/min) has been examined with filter of 60$\mu$m pore size and UV irradiation at an average dose 0.5 mWS/$cm^2$ for 5 months. For outlet seawater filter of 90 $\mu$m pore size only was used. Temperature, salinity, pH, $NO_3-N,\;NO_2-N,\;NH_4-N,\;PO_4-P$, DO and COD of inlet and outlet seawater in the system were not influenced. However, the removing rate of suspended solid and turbidity of inlet seawater were appeared to be $48.7\~65.6\%$ (average $51.9\%$) and $33/3\~42/5\%$ (average $34.8\%$) after passing through screen filter respectively. Also, germicidal efficiency to the total bacteris and Vibrio species were $16.7\~20.2\%$ (average $19.2\%$) $20.0\~21.9\%$ (average $20.9\%$) respectively after passing through UV irradiation. After passing through drum filter of 90$\mu$m pore size, suspended solid and turbidity of outlet seawater were appeared to be $42.7\~52.6\%$ (average $46.9\%$), $27.7\~29.9\%$ (average $28.3\%$), respectively.

  • PDF

Investigation on the pressure drop characteristics of oscillating flow through regenerator under pulsating pressure conditions (맥동압력조건에서 재생기를 통한 왕복유동의 압력강하 특성에 대한 연구)

  • 최성열;남관우;정상권
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.21-27
    • /
    • 2003
  • This paper proposes a new model of the pressure drop for more accurate description of oscillating flow through regenerator under pulsating pressure conditions in contrast to an existing model based on steady flow. For the universal uses of the oscillating flow model, non-dimensional parameters, which consist of Reynolds number, Valensi number gas domain length ratio, oscillating flow friction factor and phase angle of pressure drop, are derived from the capillary tube model of the regenerator. Two correlation equations of the model are obtained from the experiments for the twill square screen regenerators under various operating frequencies and inlet mass flow rates. The oscillating friction factor is a function of only the Reynolds number and the phase angle of pressure drop is a function of the Valensi number and the gas domain length ratio. Experiment is also performed to examine the effects of the shape of screens.

  • PDF

Comparison of Flow Characteristics for the Development of a C-Type Strainer with Its Inlet and Outlet on a Straight Line (유입·유출구가 일직선상인 C형 스트레이너 개발을 위한 유동특성 비교)

  • Shin, Byung-kyun;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.257-265
    • /
    • 2016
  • The purpose of this study was to develop a strainer that could protect a flow system by blocking the introduction of foreign substances into the pipe of industrial or architectural facilities. Strainers are installed at the front tip of valves, machines, or pumps in the piping line of clean water, oil, or gas. There are Y-type, U-type, and T-type strainers. The study identified problems with the Y-type strainers, develop a "C-type strainer with its inlet and outlet on a straight line" as a more improved new model, and compared them in functions in a full-scale strainer test. The study conducted a full-scale strainer test according to four situations at the flow laboratory of Korea Research Institute of Standards and Science by using the old Y-type strainer and C-type strainer 50A. The test results show that the C-type strainer had a higher capacity coefficient(Kv) than the Y-type one, recording 74.9% when there was no screen, 54.5% when there were no foreign substances in the screen, 54.2% when there was a 15% accumulation of foreign substances, and 52.4% when there was a 30% accumulation of foreign substances. The investigator conducted a test only with the 50A type due to the limitations of life-size strainers, but the results demonstrate that the C-type strainer had better flow characteristics than the Y-type one.

Design and Test of an Assembly of Air Intake and Variable Geometry Inertial Separator for a Turboprop Aircraft (터보프롭 항공기용 흡입구 덕트 및 가변형 관성분리기 조립체 설계 및 시험)

  • Kim, Woncheol;Oh, Seonghwan;Lee, Sanghyo;Park, Jonghwa
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.714-719
    • /
    • 2013
  • A turboprop aircraft for this study is required to operate at icing condition in order that it performs its given mission. So an air intake system of the turboprop aircraft should be designed and verified not only to provide the maximum possible total pressure at engine inlet at normal flight condition, but also to include an inertial separator which protects Foreign Object Debris (FOD) like ice or snow at icing condition from entering into the engine inlet screen which can cause or lead an catastrophic engine failure like engine flame-out or severe damage. So an air intake assembly incorporating a variable geometry inertial separator has been designed and then CFD/structural analysis for the assembly was performed to see its design results. Then 35% scaled model of the air intake assembly was manufactured and wind tunnel test was done. This paper describes the detailed design results for the aerodynamic design, analysis and wind tunnel testing during the development process of the air intake assembly.