재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석 (Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

응축압력 변화에 따른 R407C의 응축특성에 관한 연구 (An Experimental Study on Condensation Characteristics at Various Condensation Pressure of R407C)

  • 전창덕;장경근;김창덕;이진호
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.230-238
    • /
    • 2003
  • R407C is considered as alternative refrigerant of R22 for air conditioners. Experimental investigation is made to study the condensation heat transfer characteristics of slit fin-tube heat exchanger using alternative refrigerant, R407C. Experiments are carried out at condensation pressure of 2110 kPa and 1943 kPa with the degree of superheat of 1$0^{\circ}C$ and mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air condition is dry bulb temperature of 35$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.8 to 1.6 m/s. Experiments show that pressure drop gets smaller at a higher condensation pressure especially when condensation pressure is raised from 1943 to 2110 kPa. Heat transfer rate gets smaller at a lower condensation pressure in the range of experimental condition.

고분자연료전지의 냉각수 운전 조건에 관한 실험적 연구 (An Experimental Study of Coolant Operating Conditions in a Polymer Electrolyte Membrane Fuel Cell)

  • 정성일;김태완;이창건;김두현;안영철;이재근;황유진
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.541-546
    • /
    • 2008
  • A coolant operating condition in al fuel cell stack was an important factor to determine the temperature distribution which affected the fuel cell performance and relative humidity. In this study, the fuel cell performance was evaluated as a function of the coolant flow rate with the range of $0.1{\sim}0.8$ liter/min cell and the coolant inlet temperature of $20{\sim}82^{\circ}C$. The cell temperature increased with increasing the coolant inlet temperature and with decreasing the coolant flow rate. The coolant inlet temperature and flow rate to maintain the better performance of the fuel cell were in the range of $45{\sim}60^{\circ}C$ and $0.2{\sim}0.4$ liter/min cell, respectively. The experimental results showed that the optimal heat removal rate from the stack by coolant was $0.4{\sim}0.6W/cm^2$ cell.

다중 영역법을 이용한 증발식 응축관 주위의 열 및 물질전달 해석 (Numerical study of heat and mass transfer around an evaporative condenser tube by multi-zone method)

  • 윤일철;이재헌
    • 대한기계학회논문집
    • /
    • 제19권12호
    • /
    • pp.3317-3328
    • /
    • 1995
  • The objective of the present study is to predict the characteristics of heat and mass transfer around an evaporative condenser. Numerical calculations have been performed using multi-zone method to investigate heat transfer rate and evaporation rate with the variation of inlet condition(velocity, relative humidity and temperature) of the moist air, the flow rate of the cooling water and the shape of the condenser tube. From the results it is found that the profile of heat flux is the same as that of evaporation rate since heat transfer along the gas-liquid interface is dominated by the transport of latent heat in association with the vaporization(evaporation) of the liquid film. The evaporation rate and heat transfer rate is increased as mass flow rate increases or relative humidity and temperature decrease respectively. But the flow rate of the cooling water hardly affect the evaporation rate and heat flux along the gas-liquid interface. The elliptic tube which the ratio of semi-minor axis to semi-major axis is 0.8 is more effective than the circular tube because the pressure drop is decreased. But the evaporation rate and heat flux shown independency on the tube shape.

직교유동 내에 놓인 수평 실린더에서 서리 생성에 관한 실험적 연구 (An experimental study of frost forming on the horizontal cylinder under cross flow)

  • 이윤빈;노승탁
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.448-456
    • /
    • 1999
  • Variations of thickness and effective thermal conductivity of frost forming on the horizontal] cylinder with respect to time were measured under cross flow. The local heat flux around the cylinder was determined by measuring the radial temperature distribution in the cylinder having small holes drilled axially in which T-type thermocouples were inserted, then by using one dimensional cylindrical heat conduction equation. The thickness and the surface temperature of the frost layer around the cylinder were measured periodically while developing the frost. Each experiment was peformed by varying the Reynolds number, the temperature, and the humidity condition. Specially the dew point temperature of the most cases was below the freezing point. Experimental data showed that the frost layers on the front and the rear surface were thicker than those on the top and the bottom one which was near the separation point. The thickness and effective thermal conductivity of the frost layer were affected by inlet air velocity, temperature, and humidity. Moreover, the effective thermal conductivity and the effective thermal resistance increase with respect to time.

  • PDF

착상조건 하에서 핀-관 열교환기의 성능예측을 위한 컴퓨터 시뮬레이션 (A Computer Simulation for Performance Prediction of Fin-Tube Heat Exchanger under Frosting Conditions)

  • 이관수;박희용;이욱용;이태희;이수엽;이명렬
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.161-170
    • /
    • 1995
  • This study is concerned with the numerical analysis of performance on fin-tube heat exchanger under frosting condition. In this work, tube-by-tube method using LMED is employed. The present results are compared with O'Neal's experimental and numerical results. A standard evaporator model with 2rows-2columns is selected to investigate the effects of the various parameters such as fin pitch, air flow velocity, and humidity. The results show that frost thickness and the amount of frost per unit area decrease as fin-pitch becomes narrower. In the meantime, frost thickness and accumulation rate increase with higher inlet air humidity. It is shown that heat transfer rate increases during 30minutes and then it decreases. Heat transfer rate and the amount of frost increase with air velocity, however frost thickness does not increase over a certain velocity.

  • PDF

군산해역에 있어서 소규모 바다목장화를 위한 해양저질 환경 평가 (Environmental Evaluation of Sediment Quality for Small Scale Marine Ranch around the Gunsan Coastal Areas)

  • 김종화;김종규;박병수
    • 수산해양교육연구
    • /
    • 제20권3호
    • /
    • pp.508-519
    • /
    • 2008
  • Hot air drying is a method that let moistures evaporate by heat exchange between heating air and dry target. This way is dominating more than about 70% of dryers that the use extent is wide fairly, and is established in domestic than dryer that use conduction or radiation etc. Most of research about drying had been emphasized in size of device through analysis for these dry phenomenon plain, heating topology, and aspect of form and so on by dry target's special quality, and research about device development or waste heat withdrawal technology in energy utilization efficiency side is slight real condition. Therefore, in this study, Investigated numerically about thermal efficiency elevation that is leaned against as that change the temperature of inlet and outlet in heat exchanger of the hot air drying tower.

동일한 유입온도조건에서 R134a와 R22 적용 응축기의 특성비교 (Comparison of Condenser Characteristics using R134a and R22 under the Same Inlet Temperature Condition)

  • 강신헝;변주석;김창덕
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.166-173
    • /
    • 2006
  • 본 연구에서는 상용 냉동 공조기기에서 사용하고 있는 휜-관 열교환기에서 R22와 이의 대체냉매로 채용하고 있는 R134a 압력강하와 열전달 특성에 대해 실험적으로 연구하였다. 실험은 입구온도 $60^{\circ}C$, 질량유량 $150,\;200,\;250\;kg/m^{2}s$의 범위에 대해 수행하였다. 이때 공기의 유입조건은 전구온도 $35^{\circ}C$, 상대습도 40%, 공기유속은 $0.68{\sim}1.6m/s$이다. 실험 결과 응축기 출구의 과냉도를 $5^{\circ}C$로 유지한 경우 Rl34a의 필요공기유속은 R22보다 5.9%작게 나타났으며, R134a의 압력강하는 R22보다 $18.1{\sim}20.4%$의 범위 내에서 크게 나타났다.

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.