• Title/Summary/Keyword: Inlet & outlet temperature

Search Result 358, Processing Time 0.03 seconds

Study on long-term monitoring of heat exchanger installed in the tunnel lining (터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구)

  • Lee, Chulho;Park, Moonseo;Choi, Hangseok;Sohn, Byunghu;Jeoung, Jaehyeung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF

Experimental Study on Heating Performance Characteristics of Air Source Heat Pump with Air to Water Type (공기열원 히트펌프의 난방 성능특성에 관한 실험적 연구)

  • Lee, Kwon-Jae;Kwon, Young-Chul;Chun, Chong-Keun;Park, Sam-Jin;Kwon, Jeong-Tae;Huh, Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.400-405
    • /
    • 2011
  • This paper presents the heating performance characteristics of the air source heat pump with air to water type. The heating capacity, COP, P-h diagram were measured at various operating conditions, air-side temperatures, relative humidities, and inlet/outlet water temperature under the standard heating condition of KS B 6275. The experimental data for the heat pump were measured using the air-enthalpy calorimeter and the constant temperature water bath. As the air-side temperature increases, the heating capacity and COP increase. The effect of the air-side relative humidities on the heat pump performance is insignificant. The heat pump performance on inlet and outlet water temperatures and air-side temperatures(-7, -11, $-15^{\circ}C$) were studied. Heating capacity and COP increased about 27~39% with the air-side temperature increasing. Enthalpy between the front and the rear of condenser decreased about 6% by increasing of the inlet water temperature. These results can be utilized in the design of the air source heat pump system with air to water type.

A Study on the Performance of Natural Ventilation of Solar Chimney Using Stack Effect (연돌 효과를 이용한 태양열 굴뚝의 자연환기 성능에 관한 연구)

  • Cho, S.W.;Lee, J.Y.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.2
    • /
    • pp.35-43
    • /
    • 2001
  • The results of numerical simulation on the performance of a solar chimney system in building are described. The inside surface temperature of four walls within the solar chimney arc calculated with solar radiation and outdoor temperature in summer. The air within the solar chimney is heated by conduction, convection and radiation. Air temperature distribution from the bottom to the top and outlet air temperature can be obtained by solving energy balance equation. Since the buoyance or stack effect is affected by temperature difference between the bottom and the top within the solar chimney. It is evaluated using inlet and outlet temperatures. It is expected that natural ventilation by the solar chimney of witch the height is 7.8m and the cross sectional area is $4.93m^2$ can provide about $6400m^3/h$ on sunny day.

  • PDF

Design Methodology of Composite Reactive Silencer Based on Acoustic Analysis (복합형 반사형 소음기의 음향학적 특성과 설계방법)

  • Kim, Yang-Han;Choi, Jae-Ung;Kim, Yeong
    • Journal of KSNVE
    • /
    • v.1 no.1
    • /
    • pp.29-38
    • /
    • 1991
  • The performance of silencer system is controlled by the geometrical parameters such as the relative location of inlet and outlet ports, size of main chamber, and cross sectional geometry of inlet-outlet ports and main chamber of silencer. In addition to these parameters, the presence of mean flow and temperature gradient along the silencer also affects the acoustic characteristics of silencer system. Due to the complexity of silencer, it is not straight forward to design the appropriate silencer system. In this paper, a design methodology based on an oustic analysis of silencer system is proposed ; low frequency and high frequency tuning method.

  • PDF

The Characteristics of Silk Sericin/polyurethane Mixed Film (견 세리신/폴리우레탄 혼합필름의 특성)

  • 김문정;배도규
    • Journal of Sericultural and Entomological Science
    • /
    • v.40 no.2
    • /
    • pp.143-149
    • /
    • 1998
  • For the application of silk sericin, silk sericin powders were prepared by various spray dry conditions and the characteristics of silk sericin/polyurethane mixed films were investigated. When the sericin was dried from the solution at higher inlet and outlet temperature, larger sizes of the powder particles were obtained. It was also found that inlet and outlet temperatures were important factors affecting the shape and surface characteristics of sericin power particle. The many holes and empty spaces were observed at the surface and cross section of sericin/PU mixed film. With the increase of the amount of sericin powder in the mixed films, the size and number of holes and empty spaces were increased. The thickness of sericin/PU mixed film was increased with the content of sericin powder. As the portion of sericin powder increase, the tenacity is decreased while the elongation slightly increased.

  • PDF

Numerical Study on Comparison of Serpentine and Parallel Flow Channel in High-temperature Proton Exchange Membrane Fuel Cells (고온형 고분자전해질형 연료전지에서의 사형 유로와 평행 유로 성능비교에 대한 수치해석적 연구)

  • AHN, SUNGHA;OH, KYEONGMIN;JU, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.41-55
    • /
    • 2018
  • General polymer electrolyte fuel cell (PEMFC) operates at less than $80^{\circ}C$. Therefore liquid phase water resulting from electrochemical reaction accumulates and floods the cell which in turn increases the mass transfer loss. To prevent the flooding, it is common to employ serpentine flow channel, which can efficiently export liquid phase water to the outlet. The major drawback of utilizing serpentine flow channel is the large pressure drop that happens between the inlet and outlet. On the other hand, in the high temperature polymer electrolyte fuel cell (HT-PEMFC), since the operating temperature is 130 to $180^{\circ}C$, the generated water is in the state of gas, so the flooding phenomenon is not taken into consideration. In HT-PEMFCs parallel flow channel with lower pressure drop between the inlet and outlet is employed therefore, in order to circulate hydrogen and air in the cell less pumping power is required. In this study we analyzed HT-PEMFC's different flow channels by parallel computation using previously developed 3-D isothermal model. All the flow channels had an active area of $25cm^2$. Also, we numerically compared the performance of HT-PEMFC parallel flow channel with different manifold area and Rib interval against the original serpentine flow channel. Results of the analysis are shown in the form of three-dimensional contour polarization curves, flow characteristics in the channel, current density distribution in the Membrane, overpotential distribution in the catalyst layer, and hydrogen and oxygen concentration distribution. As a result, the performance of a real area fuel cell was predicted.

Experimental Study on the Characteristics of the Film Pressure and Temperature in a 5-Pad Tilting Pad Journal Bearing of LOP Type (LOP형 5패드 틸팅패드 저어널베어링의 압력 및 온도 특성에 관한 실험적 연구)

  • 하현천;양승헌;변형현
    • Tribology and Lubricants
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 1998
  • The static characteristics of a five-pad tilting pad journal bearing of load on pad (LOP) type have been investigated experimentally under the different values of bearing load and shaft speed. The diameter and length of the bearing are 300.91 mrn and 149.8 mm, reslx;ctively. Circumferential distribution of the film pressure, film thickness, journal surface temperature and beating surface temperature are measured. A noticeable inlet pressure rise is observed at the entrance of each pad, especially the bottom pad. The inlet pressure is increased by the increase of shaft speed as well as bearing load. In the five-pad tilting pad joumal bearing of LOP type, almost all of beating load is being carried only by the bottom pad. The maximum bearing surface temperature is observed at near the minimum film thickness. It is observed that the metal temperature of the mid-plane is higher than that of the edge at the inlet region, while the metal temperature of the edge is higher than that of the mid-plane at the outlet region.

The Development of Filter for Environmental Improvement in Land Based Seawater Fish Farm II. Purification efficacy of Inlet and Outlet Seawater by Filter (필터의 개발을 통한 해수 육상수조식 양식장의 환경개선에 관한 연구 II. 필터 운행에 따른 유입수 및 배출수의 정화효과)

  • KANG Ju-Chan;PARK Soo-Il;KIM Seoung-Gun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.6
    • /
    • pp.914-919
    • /
    • 1998
  • This study was conducted to evaluate the purification efficacy by filter and ultra violet (UV) irradiation against inlet and outlet seawater of the land based fish farm. Purification efficacies for inlet seawater (50$\ell$/min) has been examined with filter of 60$\mu$m pore size and UV irradiation at an average dose 0.5 mWS/$cm^2$ for 5 months. For outlet seawater filter of 90 $\mu$m pore size only was used. Temperature, salinity, pH, $NO_3-N,\;NO_2-N,\;NH_4-N,\;PO_4-P$, DO and COD of inlet and outlet seawater in the system were not influenced. However, the removing rate of suspended solid and turbidity of inlet seawater were appeared to be $48.7\~65.6\%$ (average $51.9\%$) and $33/3\~42/5\%$ (average $34.8\%$) after passing through screen filter respectively. Also, germicidal efficiency to the total bacteris and Vibrio species were $16.7\~20.2\%$ (average $19.2\%$) $20.0\~21.9\%$ (average $20.9\%$) respectively after passing through UV irradiation. After passing through drum filter of 90$\mu$m pore size, suspended solid and turbidity of outlet seawater were appeared to be $42.7\~52.6\%$ (average $46.9\%$), $27.7\~29.9\%$ (average $28.3\%$), respectively.

  • PDF

Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions (운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성)

  • Baek, Seung-Moon;Son, Chang-Hyo;Heo, Jeong-Ho;Choi, In-Soo;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1021-1026
    • /
    • 2014
  • In this paper, among various systems applying hot-gas bypass control, outdoor temperature, outlet temperature of water cooler, superheating and subcooling degree, which are the factors affecting the performance of the system bypassing hot-gas to evaporator inlet were analyzed. The main results were summarized as following. Frist of all, performance of refrigeration system bypassing hot-gas to evaporator inlet was affected by outdoor temperature, outlet temperature of water cooler, superheating and sub cooling degree. Thus, providing basic planning date of refrigeration system obtained through optimization of variables is expectable. Thus, providing the basic design data of refrigeration system can be offered by performing the optimization of these variables. Also, the feasibility of this refrigeration system proposed in this paper was obtained by analyzing operating characteristics of the system bypassing hot-gas to evaporator inlet.

Numerical Simulation of Plate Finned-Tubes Evaporator (평판핀이 부착된 증발기의 시뮬레이션)

  • Son, B.J.;Min, M.S.;Choi, S.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.4
    • /
    • pp.297-304
    • /
    • 1989
  • Development of a more satisfactory program of computing the performance on a multi-tube evaporator with continuous plate fins is attempted in this study. The fluid flow involving a change of phase make the flow properties and fluid friction factor of refrigerants, the heat transfer coefficients of refrigerant and air sides vary significantly. Taking such variations into account, a useful program is developed to predict the steady state performance of a multi-tube evaporator. The program was applied to an evaporator which has outside diameter of 10.05mm, inside diameter of 9.35mm, length of 5.4m and two rows arraied staggered. Then the variations of refrigerant quality, temperature, pressure, velocity, enthalpy, specific volume and air temperature, tube temperature were discussed. Satisfactory results were presented that the degree of superheat at the outlet side was $4.4^{\circ}C$ and the air temperature drop between the inlet and outlet of the air conditioner was $10^{\circ}C$.

  • PDF