• Title/Summary/Keyword: Injection time

Search Result 2,737, Processing Time 0.028 seconds

An Efficient Analysis Model for Process Quality Information in Manufacturing Process of Automobile Safety Belt Parts (자동차 안전벨트 부품 제조공정에서의 효율적 공정품질정보 분석 모형)

  • Kong, Myung Dal
    • Journal of the Korean Institute of Plant Engineering
    • /
    • v.23 no.4
    • /
    • pp.29-38
    • /
    • 2018
  • Through process quality information, the time required for process quality analysis has been drastically shortened, the process defect rate has been reduced, and the manufacturing lead time has been shortened and the on-time delivery rate has been improved. Therefore, The purpose of this study is to develop a quality information analysis system model that effectively shortens the time required for process quality analysis in automobile safety belt parts manufacturing process. As a result of experiments on communication operation between manufacturing execution system (MES) quality server, injection machine control computer, injection machine programmable logic controller (PLC) and terminal, in analyzing quality information, the conventional handwriting input method took an average of 20 minutes, but the new multi-network method took about 2 minutes on average. In addition, the process defect rate was reduced by 13% and the manufacturing lead time was shortened from 28 hours to 20 hours. The delivery compliance rate improved from 96 to 99%.

Modeling Dynamic Behavior and Injection Characteristic of a GDI Injector (GDI 인젝터의 동적 거동과 분사 특성에 대한 모델링)

  • Lee, Kye Eun;Kim, Na Young;Cho, Young Jun;Lee, Dong Ryul;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.210-217
    • /
    • 2017
  • A gasoline direct injection engine has an intake air temperature can be lowered by the fuel vaporization in the combustion chamber increase the volume efficiency is high compression ratio. Therefore, study for injection rate and characteristics which influence mixture formation in combustion chamber is important. Movement of the injector needle has a direct effect on the injection of the fuel, such as formation of cavitation, the fuel injection rate, etc. Therefore, recent studies on the dynamic characteristics of the injector considering the movement of the needle have been reported, but it takes a lot of time and cost to experimentally confirm the movement of the needle inside the injector. In this study, AMESim, a commercial 1-D code, and Star-CCM+, a 3-D CFD code, were used to predict the dynamic performance of the injector with needle motion. In order to predict the movement of the needle under the high pressure, the result of the surface pressure distribution according to the movement of the needle was derived by using the morphing technique of flow analysis. In addition, we predicted the injection rate of the injector considering the movement of the needle in conjunction with the 1-D code. The injection rate of the injector was measured by the BOSCH's method and the results were similar to those of the simulation results. This method can predict the injection rate and injection characteristics and this result is expected to be used to predict the performance of gasoline direct injection engines with low cost and time in the future.

A Comparative Study Between CFD and 0-D Simulation of Diesel Sprays with Several Fuel Injection Patterns Using Gas Jet Spray Model (가스제트 분무 모델을 이용한 다양한 분사 패턴의 디젤 분무에 대한 CFD 및 0-D 시뮬레이션 비교 연구)

  • Lee, Choong-Hoon
    • Journal of ILASS-Korea
    • /
    • v.17 no.2
    • /
    • pp.77-85
    • /
    • 2012
  • The CFD simulation of diesel spray tip penetrations were compared with 0-D simulation for experimental data obtained with common rail injection system. The simulated four injection patterns include single, pilot and split injections. The CFD simulation of the spray penetration over these injection patterns was performed using the KIVA-3V code, which was implemented with both the standard KIVA spray and original gas jet sub-models. 0-D simulation of the spray tip penetration with time-varying injection profiles was formulated based on the effective injection velocity concept as an extension of steady gas jet theory. Both the CFD simulation of the spray tip penetration with the standard KIVA spray model and 0-D simulation matched better with the experimental data than the results of the gas jet model for the entire fuel injection patterns.

Hyperthermia Properties of Fe3O4 Nanoparticle Synthesized by Hot-injection Polyol Process (Hot-injection Polyol 공정에 의해 제조된 Fe3O4 나노입자의 Hyperthermia 특성)

  • Lee, Seong Noh;Kouh, Taejoon;Shim, In-Bo;Shim, Hyun Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.51-55
    • /
    • 2014
  • The $Fe_3O_4$ nanoparticle was synthesized by the hot-injection method while varying the injection time of the precursor solution. The crystal structure was determined to be cubic inverse spinel with space group of Fd-3m based on X-ray diffraction (XRD) measurements and the morphology of the prepared $Fe_3O_4$ nanoparticle was studied with a high-resolution transmission electron microscope (HR-TEM). When the precursor solution was injected for 0.5 min, the size of the $Fe_3O_4$ nanoparticle was 7.63 nm, while the size of the obtained particle was 21.27 nm with the injection time of 60 min. The magnetic properties of the prepared $Fe_3O_4$ nanoparticle were investigated by both vibrating sample magnetometer (VSM) and $^{57}Co$ M$\ddot{o}$ssbauer spectroscopy at various temperatures. From the hyperthermia measurement, we observed that the temperature of the $Fe_3O_4$ nanoparticle powder reached around $120^{\circ}C$ under 250 Oe at 50 kHz, when the injection time of the precursor solution was 60 min.

A Study on the Design of the LIGBT Structure with Trap Injection for Improved Electrical Characteristics (트랩 주입의 구조적 설계에 따른 LIGBT의 전기적 특성 개선에 관한 연구)

  • Choo, Kyo-Hyuck;Kang, Ey-Goo;Lee, Jung-Hoon;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.932-934
    • /
    • 1999
  • In this paper, the new IGBT structures with trap injection are proposed to improve switching characteristics of the conventional SOI LIGBT. The simulations are used in order to investigate the effects of the position, width and concentration of trap injection region using 2D device simulator MEDICI. And, their electrical characteristics are analyze and the optimum design parameters are extracted. As a result of simulation, the turn off time for the proposed LIGBT model A by the trap injection is $0.78{\mu}s$. And, the latch up voltage is 3.4V and forward blocking voltage is 168V which are superior to that of conventional structure. In addition, the proposed model is achieved more efficient in switching time and process effort. Therefore, It is shown that the trap injection is very effective to reduce the turn off time with a little increasing of on-state voltage drop if its design and process parameters are optimized.

  • PDF

Pain control using the Point-Inject Technique in dental local anesthesia (Point Inject Technique을 이용한 치과 국소마취의 통증 조절 및 진료 효율의 극대화)

  • Lee, Jae-youn;Choe, Sunga
    • Journal of Korean Academy of Dental Administration
    • /
    • v.9 no.1
    • /
    • pp.32-37
    • /
    • 2021
  • Many approaches to local anesthesia have been studied in dentistry. In this study, we introduce a new local anesthetic method, "Point-Inject Technique (PIT)", and compare it with traditional injection techniques. The PIT method utilizes both the vasoconstrictive and antinociceptive properties of local anesthetics as well as the application of controlled pressure during injection, reducing the time to complete anesthesia. Fifty patients were selected as the experimental group who were anesthetized using PIT, and the other 50 patients were selected as the control group using the direct injection method with a carpool syringe. The PIT group received 0.25 cartridges of 2% lidocaine with 1:100,000 epinephrine. The control group received 1.5~2 cartridges of 2% lidocaine with 1:100,000 epinephrine. Both groups were asked to mark the intensity of the pain caused by anesthesia using the Numeric Pain Rating Scale. The average time to recover from anesthesia was 40 minutes in the experimental group and 90 minutes in the control group. Additionally, 96% of the experimental group reported feeling no pain, while 78% of the control group reported having some form of pain during injection. The PIT method reduced both the reported pain scores of patients as well as time to recover from local anesthesia than the widely-used syringe injection method.

EFFECTS OF A SPLIT INJECTION ON SPRAY CHARACTERISTICS FOR A COMMON-RAIL TYPE DIESEL INJECTION SYSTEM

  • PARK S. W.;SUH H. K.;LEE C. S.
    • International Journal of Automotive Technology
    • /
    • v.6 no.4
    • /
    • pp.315-322
    • /
    • 2005
  • This work was performed to investigate the effect of a split injection on spray characteristics of fuel sprays injected from a common rail system. In order to analyze the spray behavior and atomization characteristics at various rates of split injections, the injection durations of pilot and main injections were varied in experiments. The injection rate of split injection was measured to study the effect of the pilot injection on the main injection. By using a Nd:YAG laser and an ICCD camera, the development of the injected spray was visualized at various elapsed time from the start of injection. The microscopic characteristics such as SMD and axial velocity were analyzed by using a phase Doppler particle analyzer system. The results indicate that the ambient gas flow generated by the pilot injection affects the behavior of main spray, whereas the effect of pressure variation on the main spray is little. The spray tip penetration of a main spray with pilot injection is longer than that of the single injection by the effect of ambient gas flow. Also the main spray produces larger droplets than the pilot spray due to a small relative velocity between the droplets and ambient gas.

The Effects of Oocyte Preparation on the Developing Capacity of Human Oocytes at Intracytoplasmic Sperm Injection (ICSI) (난자내 정자 직접주입술에서 난자의 처리방법이 난자의 발생능력에 미치는 영향)

  • Park, Kee-Sang;Lee, Taek-Hoo;Song, Hai-Bum;Chun, Sang-Sik
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.3
    • /
    • pp.399-405
    • /
    • 1999
  • Objective: In the preparation of ICSI, cumulus and corona cells should be removed from the oocytes by using a combination of enzymatic (hyaluronidase) and mechanical (pipetting) methods. But little is known about the effects of different degrees of oocyte denudation and incubation time between denudation and sperm injection on the outcomes of ICSI. The aim of this study was to evaluate the effects of varying the degrees of oocyte denudation and the lengths of incubation time from denudation to sperm injection on the outcomes of ICSI. Methods: In experiment 1, patients (oocytes) were grouped into group A and B according to the degree of denudation, complete and partial, respectively. In experiment 2, patients (oocytes) were grouped into group I, II and III according to the length of incubation time of denuded oocytes until sperm injection as < 1, $1{\sim}2$ and >2 hours, respectively. Results: There was no significant difference between the degree of oocyte denudation on the survival, fertilization and development rates after ICSI procedure. In case of the incubation time of denuded oocytes until ICSI, survival rates was higher in group III (83.1 %) than in group I (61.5%, p<0.05) or group II (64.3%). However no statistically significant differences were found between incubation time and fertilization or development rates. Conclusions: This study reveals that the outcomes of ICSI are not affected by the degree (complete or partial) of oocyte denudation. However, the denuded oocytes with incubation period of more than 2 hours show better outcomes of ICSI than those with the incubation period of less than 2 hours.

  • PDF

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

Hinge Design and Injection Molding Simulation of Cosmetic Cushion Fact Container Using Eco-Friendly Materials (친환경 소재를 이용한 화장품 쿠션 팩트 용기의 힌지 설계와 사출 성형 시뮬레이션)

  • Jung, Sung-Taek;Kim, Hyun-Jeong;Wi, Eun-Chan;Kim, Min-Su;Lee, Joong-Bae;Baek, Seung-Yub
    • Design & Manufacturing
    • /
    • v.13 no.3
    • /
    • pp.35-40
    • /
    • 2019
  • As the consumer market in the cosmetic, vehicle manufacturing and aerospace industries grows, the demand for manufacturing industries using on injection mold technology. Also, such manufacturing technology of metal machining is expensive, and the shape is limited. Cosmetic cushion fact products are divided into outer relevant to the exterior of the product and inner containers containing the actual contents. In the case of the inner container, it needs to be combined with the upper and lower cases. As environmental regulations are strengthened internationally, the use of a large number of component parts can result in significant losses in recycling and economics. Therefore, this study aims to perform injection molding analysis through injection molding simulation to develop a cushion fact container that can be recycled through the unification of products and materials using polypropylene to cope with environmental regulations. In the case of injection molding conditions, Injection Time(sec): 4.5, Cooling Time(sec): 13, Resin Temperature($^{\circ}C$): 240, and Pressure(MPa): 30 were determined. The results of injection molding simulation according to the two design methods were compared with the sync mark which shows the problem of filling and injection molding.