• Title/Summary/Keyword: Injection pressure

Search Result 2,436, Processing Time 0.031 seconds

Hydrodynamic Characteristics of Absorbent and Catalyst for Pre-combustion CO2 Capture (연소 전 이산화탄소 회수를 위한 흡수제 및 촉매의 수력학적 특성)

  • Ryu, Ho-Jung;Yoon, Joo-Young;Lee, Dong-Ho;Shun, Dowon;Park, Jaehyeon;Park, Yeong-Seong
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.437-445
    • /
    • 2013
  • To develop SEWGS (sorption enhanced water gas shift) system using dry $CO_2$ absorbent for pre-combustion $CO_2$ capture, hydrodynamic characteristics of $CO_2$ absorbents were measured and investigated. The minimum fluidization velocity of $CO_2$ absorbent was measured and the effects of the operating conditions were investigated to operate the system at bubbling fluidized bed condition. The minimum fluidization velocity decreased as pressure and temperature increased. Moreover, the minimum fluidization velocity decreased as column diameter increased. The effects of operating conditions on the solid circulation rate were measured and investigated to select appropriate operating conditions for continuous $CO_2$ capture and regeneration. The measured solid circulation rates were ranged between 10 and 65 kg/h and increased as the solid injection velocity, gas velocity in the regeneration reactor, and solid height increased.

Prediction of Surgical Anesthesia in Medetomidine/Tiletamine/Zolazepam Anesthetized Dogs using Electroencephalography (Medetomidine/Tiletamine/Zolazepam 마취견에서 뇌전도를 이용한 외과마취의 평가)

  • Jang, Hwan-Soo;Kim, Jung-Eun;Lim, Jae-Hyun;Kwon, Young-Sam;Lee, Maan-Gee;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.540-545
    • /
    • 2010
  • Changes of electroencephalogram (EEG), mean arterial blood pressure (MAP) and heart rate under surgical anesthesia were investigated in medetomidine (MED) and tiletamine/zolazepam (ZT)-anesthetized dogs. To determine the level of surgical anesthesia, pedal withdrawal reflex was regularly tested after ZT injection. The first time point without pain response was regarded as the beginning of surgical anesthesia (SSA). After SSA, the first time point showing positive pain response was considered the end of surgical anesthesia (ESA). Comparing the control, an additional significant decrease of ${\delta}2$ and ${\alpha}2$ was observed at SSA. Comparing the control, ${\delta}2$ was significantly decreased at ESA. Significant reductions of MAP were observed at pre-ESA and ESA. Heart rate significantly decreased in all stages. These results suggest that ${\delta}2$ band power is a valuable parameter for correlating surgical anesthesia in dogs anesthetized with MED and ZT.

Dependence of $O_2$ Plasma Treatment of ITO Electrode on Electrical and Optical Properties of Polymer Light Emitting Diodes (ITO 투명전극의 $O_2$ 플라즈마 처리가 고분자 유기발광다이오드의 전기.광학적 특성에 미치는 영향)

  • Gong, Su-Cheol;Back, In-Jea;Yoo, Jea-Huyk;Lim, Hun-Sung;Yang, Sin-Huyk;Shin, Sang-Bea;Shin, Ik-Seup;Chang, Gee-Keun;Chang, Ho-Jung
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.3
    • /
    • pp.93-97
    • /
    • 2006
  • Polymer light emitting diodes (PLEDs) are expected to be commercialized as next generation displays by advantages of the fast response time, low driving voltage and easy manufacturing process for large sized flexible display. Generally, the electrical and optical properties of PLEDs are affected by the surface conditions of transparent electrode. The PLED devices with ITO/PEDOT:PSS/PVK/PFO-poss/LiF/Al structures were prepared by using the spin coating method. For this, PEDOT:PSS(poly(3,4-ethylenedioxythiophene):poly(styrene sulfolnate)) Al 4083 and PVK(N-vinylcabozole) were used as hole injection and transport layers. The PFO-poss(poly(9,9-dioctylfluorene)) was used as the emitting layer. The dependence of $O_2$ plasma treatment of ITO electrode on the electrical and optical properties of PLEDs were investigated. The sheet resistances increased slightly with an improved surface roughness of ITO electrode as the RF power increased during $O_2$ plasma treatment. The PLED devices prepared on the ITO/Glass substrates, which were plasma-treated at 40 watt in RF power for 30 seconds under 40 mtorr $O_2$ pressure, showed the maximum external emission efficiency of 0.86 lm/W and the maximum luminance of $250\;cd/m^2$, respectively. The CIE color coordinates are ranged $X\;=\;0.13{\sim}0.18$ and $Y\;=\;0.10{\sim}0.16$, showing blue color. emission.

Preparation and Evaluation of $PGE_1$ Transurethral Suppositories (프로스타글란딘 $E_1$ 요도좌제의 제조 및 평가)

  • Kim, Jong-Oh;Quan, Qi-Zhe;Rhee, Jong-Dal;Choi, Han-Gon;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.3
    • /
    • pp.173-178
    • /
    • 2000
  • The purpose of this work is to develop a transurethral suppository containing prostaglandin $E_1\;(PGE_1)$, which stabilizes the drug, gives no irritation to physiological body and enhances the erectile response of $PGE_1.\;PGE_1$ transurethral suppositories were prepared with various amounts of compositions such as saturated polyglycolysed glyceride $(Suppocire^{\circledR}\;AP,\;SAP)$, polyoxyethylene hydrogenated castor oil (HCO-50) and ethanol. The melting points, viscosities and $PGE_1$ release of the suppositories were investigated. Ocular irritation test was carried out after application of $PGE_1$ suppository to rabbit's eye. The intracavernous pressure (ICP), penile length and duration of erectile response were determined after transurethral administration of $PGE_1$ suppository and compared with those after intracavernosal injection of $PGE_1$ solution to cats. HCO-50 hardly affected the melting points and viscosities of $PGE_1$ suppositories. Additionally, $PGE_1$ transurethral suppositories, whose melting point ranges was $34-35^{\circ}C$, was speedily melted in physiological body. HCO-50 significantly decreased the dissolution rates of $PGE_1$ from the suppositories. Dissolution mechanism analysis showed the release of $PGE_1$ was proportional to the square root of time, indicating that $PGE_1$ might be released from the suppositories by Fickian diffusion. The release rate of $PGE_1$ from $PGE_1$ suppository [PGE1/SAP/HCO-50/ethanol (1/94.5/2.5/2%)] was about 80% within 2 h. This $PGE_1$ suppository gave no significant irritation to the ocular tissue, expecting that it gave no irritation to the urethral tissue less sensive than ocular tissue. Furthermore, $PGE_1$ in this suppository was stable at $4^{\circ}C$ for 2 years. This suppository increased the ICP and penile erection similar to those of injectable $PGE_1$ solution. However, it gave 2.5-fold increased duration of erectile response than injectable $PGE_1$ solution. Our results suggested that it gave more effective erectile response than injectable $PGE_1$ solution in cats. It is concluded that this $PGE_1$ suppository with good safety, excellent stability and enhanced erectile response, could be a more effective and convenient transurethal delivery system of $PGE_1$.

  • PDF

Determination Method of Hydrocarbon Compounds in DME-LPG Blending Fuels by Gas Chromatography with Deans Switching (Deans Switching을 이용한 가스크로마토그래피에서 DME-LPG 혼합연료의 탄화수소 화합물 분석방법)

  • Youn, Ju Min;Park, Cheon Kyu;Yim, Eui Soon;Jung, Choong Sub
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.353-357
    • /
    • 2012
  • The new qualitative and quantitative analytical method for hydrocarbon compounds in DME-LPG blending fuel, mixing dimethyl ether (DME) with liquefied petroleum gas (LPG), by using gas chromatography (GC) was investigated. It is difficult to analyze all components of DME-LPG blending fuel by using single column in GC due to consisting of the non-polar LPG and the polar DME which is oxygen-containing compound. Therefore, it has been introduced the Deans switching system, which are useful for analyzing mixtures of a very different nature and/or target analytes in very complex matrix. This technique is to control the pressure between two columns and to selectively change the path of effluent flows to either one of two columns. As a result, we found that DME and LPG can be completely separated at the different columns and the determination of all hydrocarbon compounds in DME-LPG blending fuel can be achieved to this method qualitatively and quantitatively during the operation of one injection. In addition, this method can be applied to the determination of trace components of by-product, such as methanol, methyl formate and ethyl methyl ether, which will be derived from DME synthesis process.

Spinal Anesthesia for Lower Extremities : Comparison of Plain 0.5% Bupivacaine and Hyperbaric 0.5% Tetracaine (하지수술을 위한 0.5% 순수 Bupivacaine 척추마취)

  • Song, Sun-Ok;Koo, Bon-Up
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 1990
  • Plain 0.5% bupivacaine and hyperbaric 0.5% tetracaine were compared for spinal anesthesia in 40 patients undergoing operation of lower extremities. Lumbar puncture was performed with a 22 gauge spinal needle with the patient in the lateral recumbent position. The third lumbar interspace was chosen for the puncture, when a free flow of clear CSF was obtained, the local anesthetic solution (2.5ml of 0.5% bupivacaine or 2.0ml of hyperbaric 0.5% tetracaine) was injected at a rate of 0.1ml/sec without barbotage. After injection of anesthetics, clinical features were observed and compared between the two groups. The results were as follows : 1. The two groups were well matched for age, sex, height and weight. 2. In both groups, sensory block to $T_{12}$ dermatome was obtained within 4 minutes, mean maximal level of analgesia was $T_{6-7}$, and the mean time for maximal level was around 20 minutes. 3. The onset times of motor block were similar in both groups and complete motor block was obtained in all cases within 20 minutes. 4. The duration of analgesia above the $T_{12}$ dermatome was 3 hours, postoperative analgesia was 7 hours. These values were significantly prolonged than those of the tetracaine group(p<0.05). 5. The changes in systolic pressure in the bupivacaine group were significantly less than those of the tetracaine group(p<0.05). 6. The complications after spinal anesthesia were headache, numbness, urinary retention and backpain, and were no significant difference in both groups. From the obtained results, we concluded that plain 0.5% bupivacaine was a relatively satisfactory agent for spinal anesthesia for operation of lower extremities. The time of onset, height of block and the complications of postoperative period were similar in both groups. The advantages of plain 0.5% bupivacaine were less hypotension and long duration of analgesia.

  • PDF

THE USE OF BISPECTRAL ANALYSIS AND HEMODYNAMIC MONITORING IN PATIENTS UNDERGOING INTRAVENOUS SEDATION FOR MINOR ORAL SURGERY (구강악안면외과 소수술시 정맥 의식하 진정법에서의 Bispectral Index and Hemodynamics monitoring을 이용한 진정 깊이에 관한 연구)

  • Shin, Jung-Sub;Min, Hyun-Gi;Lee, Ju-Hyon;Lee, Dong-Hyun;Kim, Myung-Rae;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.567-571
    • /
    • 2008
  • Purpose: The purpose was to assess the usefulness of midazolam in patients undergoing minor oral surgery under conscious sedation. Materials and methods: Bispectral index was examined in 20 patients receiving oral minor surgery with conscious sedation supplemented with local anesthesia. All patients included were ASA I and had no contraindications to the study medications. The patients were escorted to the day surgery operation room where, before the commencement of the sedation and surgical procedures, routine monitoring was applied, including the noninvasive monitoring of arterial blood pressure, arterial oxygen saturation, and 3-lead electrocardiogram (Electrocardiogram). Bispectral index electrodes were applied on the frontotemporal region after cleansing the skin with alcohol. Bispectral index was calculated with the Electrocardiogram monitor (A-2000; Aspect Co.). Midazolam was then titrated (initially 3mg wait 2min and 2mg). Vital sign and Bispectral index checked every 5 minute until the end of the procedure. The results were then compared. Results: The Bispectral index index values throughout the sedation study period alter many level. The index was dropped at 5 minutes after administration, but raised at injection and odontomy procedure. During the operation, mean Bispectral index index was higher than conscious sedation index range($60{\sim}80$). The amnesic effect was shown 17 cases out of 20 cases(85%). Conclusion: Conscious sedation technique using midazolma is a safe and effective method of controlling behavior in oral and maxillofacial surgery.

Study of Failure Examples for Emission Gas Control System in Gasoline Engine (가솔린 엔진 배출가스 제어장치에 대한 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Lee, Young Suk;Youm, Kwang Wook;han, Jae Oh;Lim, Ha young
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The purpose of this paper is to study for the emission gas control of passenger car. The first example, the PCSV never open when operating condition, but it opened by causing malfunction because of trouble. As a result, the purge gas entered into surge tank, a mount of fuel was displayed with excessive supply on tester. Therefore, it certified the bad-condition of the engine when idling by decreasing of fuel injection quantity from engine ECU. The second example, the hose activating a EGR valve didn't supply the vacuum pressure because of assembling the other part. Thus, it knew the bad-condition of engine that the EGR valve would not work normally by leaking with the other port. The third example, as the rear oxygen sensor of two sensor were fault-installing by changing the sensor of other a car it could not detect of oxygen quantity. Finally, it found the phenomenon of abruptly decreasing vehicle speed when braking a car. Therefore, the system including with emission control has to drastically manage by maximizing condition to role decreasing the emission gas.

Effect of CNG Heating Value Variations on Emissions Characteristics in a Diesel-CNG Dual-Fuel Engine (CNG 발열량 변화가 Diesel-천연가스 혼소엔진 배기 특성에 미치는 영향)

  • Jang, Hyongjun;Yoon, Junkyu;Lee, Sunyoup;Kim, Yongrae;Kim, Junghwan;Kim, Changgi
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.43-49
    • /
    • 2016
  • In this paper, purpose of study is emissions characteristics according to effects of heating value variations of CNG fuel in a dual-fuel engine fueled by diesel and natural gas. For heating value variation of CNG fuel, nitrogen gas was mixed with pure CNG fuel. So the higher heating value was changed from $10,400kcal/Nm^3$ to $9,400kcal/Nm^3$. Under one condition of CNG substitution rate was fixed at 80%, diesel fuel was injected at a fixed injection timing of 16 CAD BTDC and fuel pressure was also fixed at 110 MPa. The condition of tested engine was 1800 rpm and 500Nm. Emissions were sampled in exhaust pipe was located at downstream turbocharger. As a result, emissions characteristics were checked in heating value variations of CNG fuel with mixed nitrogen gas THC, $CH_4$ and CO emissions decreased and NOx and $CO_2$ increased.

Toxicity of Eun-bi San Pharmacopuncture Injection inthe Muscle of Rats

  • Lee, Jongcheol;Jeong, Hohyun;Cha, Eunhye;Park, Manyong;Choi, Sungyoul;Yook, Taehan;Song, InJa;Kim, Sungchul
    • Journal of Pharmacopuncture
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2015
  • Objectives: This study was carried out to analyze the single-dose toxicity of Eun-Bi San pharmacopuncture injected into the muscle of Sprague-Dawley (SD) rats. Methods: All experiments were performed at Biotoxtech, an institution certified to conduct non-clinical studies under the Good Laboratory Practice (GLP) regulations. Six week old SD rats reared by ORIENTBIO were chosen for this pilot study. The reason SD rats were chosen is that they have been widely used in safety tests in the field of medicine, so the results can be easily compared with many other databases. The Eun-Bi San pharmacopuncture was made in a clean room at the Korean Pharmacopuncture Institute (KPI, K-GMP). The constituents of the Eun-Bi San pharmacopuncture are Angelicae gigantis radix, Strychni semen and Glycyrrhizae radix. These were extracted at low temperature and low pressure in an aseptic room at the KPI. Doses of Eun-Bi San pharmacopuncture, 0.25, 0.5 and 1.0 mL, were administered to the experimental groups, and a dose of normal saline solution, 1.0 mL, was administered to the control group. This study was performed under the approval of the Institutional Animal Ethics Committee of Biotoxtech Co., Ltd. Results: No deaths or abnormalities occurred in any of the four groups. No significant changes in weight, hematological parameters or clinical chemistry between the control group and the experimental groups were observed. To determine if abnormalities existed in any organs and tissues, we used microscopy to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs or tissues. Conclusion: The results of this study suggest that treatment with Eun-Bi San pharmacopuncture is relatively safe and that its clinical use may be beneficial. Further evaluations and studies on this subject will be needed to provide more concrete evidence in support of these conclusions.