• Title/Summary/Keyword: Injection practice

Search Result 215, Processing Time 0.029 seconds

Single-Dose Intramuscular Toxicity Test Using No-Pain Pharmacopuncture in Sprague-Dawley Rats

  • Ji Hye Hwang;Chul Jung
    • Journal of Pharmacopuncture
    • /
    • v.26 no.1
    • /
    • pp.86-93
    • /
    • 2023
  • Objectives: This study aimed to evaluate the potential toxicity of a recently developed and clinically used No-Pain pharmacopuncture (NPP) solution. We also assessed the lethal dose of the NPP agent following a single intramuscular injection in Sprague-Dawley (SD) rats. Methods: Animals were divided into two groups: the NPP test material group and the normal saline control group. A single intramuscular injection of the NPP agent (1.0 mL/animal) was administered to rats of the NPP test material group. The control group rats received the same volume of normal saline. Both female and male rats were included in each group. All rats were monitored for clinical signs and body weight changes for 14 days after administration of the test substance or saline. At the end of the observation period, a gross necropsy was conducted and localized tolerance at the injection site was analyzed. Results: No mortality was observed in the NPP test material and control groups. Moreover, no test substance-related effects were observed on clinical signs, body weight, necropsy findings, and localized tolerance at the injection site. Conclusion: The approximate lethal dose of the NPP agent is greater than 1.0 mL/animal under the conditions used in this study. Additional toxicity evaluations and clinical studies are needed to confirm the safety of NPP use in clinical practice.

Injection Molding Analysis of Map Pocket with a Speaker Grill Using Shell Element (박막 요소를 이용한 스피커 그릴 일체형 맵 포켓의 사출 성형 해석)

  • Kim, Hong-Seok;Jo, Myeong-Sang;Son, Jung-Sik;Seo, Tae-Su;Kim, Tae-Ung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1294-1301
    • /
    • 2001
  • In order to reduce the time and cost for assembly, automobile speaker grills have been injection molded with door trims or map pockets in one piece recently. However, several defects such as short shots or air traps can easily occur due to the decreased fluidity of the melting polymer according to the excessive heat transfer to the mold. Therefore, it is necessary to optimize the resin feed system and predict possible defects by CAE analysis. However it is not possible to obtain exact analysis results for the speaker grill by using general shell elements since the heat transfer in the thickness direction which is the dominant factor of the filling stage can not be considered. Therefore, there have been several efforts to simulate the injection molding nature of the speaker grill by using shell elements with an effective thickness which is smaller than the actual thickness of the part. Two empirical values have been recommended for the effective thickness in real practice. One is 50∼70% of the thickness of the speaker grill and another is the gap distance between the adjacent holes. In this paper, CAE analyses of a map pocket with a speaker grill were conducted using shell elements with both of these recommended effective thicknesses, and the predicted flow fronts were compared with the findings from injection molding experiments. The commercial code MOLDFLOW was used for injection molding analysis and an 850 ton injection molding machine was used for experiments.

Review of Injection-Locked Oscillators

  • Choo, Min-Seong;Jeong, Deog-Kyoon
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Handling precise timing in high-speed transceivers has always been a primary design target to achieve better performance. Many different approaches have been tried, and one of those is utilizing the beneficial nature of injection locking. Though the phenomenon was not intended for building integrated circuits at first, its coupling effect between neighboring oscillators has been utilized deliberately. Consequently, the dynamics of the injection-locked oscillator (ILO) have been explored, starting from R. Adler. As many aspects of the ILO were revealed, further studies followed to utilize the technique in practice, suggesting alternatives to the conventional frequency syntheses, which tend to be complicated and expensive. In this review, the historical analysis techniques from R. Adler are studied for better comprehension with proper notation of the variables, resulting in numerical results. In addition, how the timing jitter or phase noise in the ILO is attenuated from noise sources is presented in contrast to the clock generators based on the phase-locked loop (PLL). Although the ILO is very promising with higher cost effectiveness and better noise immunity than other schemes, unless correctly controlled or tuned, the promises above might not be realized. In order to present the favorable conditions, several strategies have been explored in diverse applications like frequency multiplication, data recovery, frequency division, clock distribution, etc. This paper reviews those research results for clock multiplication and data recovery in detail with their advantages and disadvantages they are referring to. Through this review, the readers will hopefully grasp the overall insight of the ILO, as well as its practical issues, in order to incorporate it on silicon successfully.

Comparison of pain intensity of anterior middle superior alveolar injection with infiltration anesthetic technique in maxillary periodontal surge

  • Shirmohammadi, Adileh;Faramarzi, Masoumeh;Lafzi, Ardeshir;Kashefimehr, Atabak;Malek, Sepideh
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.45-49
    • /
    • 2012
  • Purpose: The aim of the present clinical trial was to compare pain during injection of anterior middle superior alveolar (AMSA) technique with that of infiltration injection technique in the maxilla in periodontal flap surgeries of patients referring to the Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences. Methods: Twenty subjects with an age range of 20 to 40 years were selected for the present study. One side of the maxilla was randomly selected as the test side and the other as the control side using a flip of a coin. AMSA technique was used on the test side and infiltration technique was used on the control side for anesthesia. On both sides 2% lidocaine containing 1:80,000 epinephrine was used for anesthesia. The operator obtained the visual analogue scale for each patient immediately after the injection and immediately after surgery. Data was analyzed using descriptive statistical methods (frequency percentages, means and standard deviations) and Wilcoxon's test using SPSS ver. 13 (SPSS Inc.). Statistical significance was defined at P<0.05. Results: There were no statistically significant differences in pain during injection between the two techniques (P=0.856). There were statistically significant differences in postoperative pain between the two injection techniques (P=0.024). Conclusions: Postoperative pain in AMSA injection technique was less than that in the infiltration technique. Therefore, the AMSA technique is preferable in the periodontal surgeries for the anesthesia of palatal tissues given the fact that it has other advantages, too.

Analysis on Basic Nursing Content Required for the Clinical Performance by Novice Nurses (신규간호사의 임상실무수행을 위해 필요한 기본간호내용 분석)

  • Byeon Young-Soon;Lim Nan-Young;Kang Kyu-Sook;Sung Myung-Sook;Won Jong-Soon;Ko Il-Sun;Chang Sung-Ok;Jang Hee-Jung;Yang Sun-Hee;Kim Hwa-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.3
    • /
    • pp.427-436
    • /
    • 2003
  • Purpose: The purpose of this study was to identify nurses' perceptions of the importance of concrete items as a basis for nursing practice. A total of 179 concrete items for basic nursing, which clinical nurses must know in order to practice appropriately, were identified. Method: The participants in this study were 225 nurses who had worked for two to five years in university hospitals. The nurses were asked to rate the importance of the 179 items (in 39 middle range categories) on a 5 point scale. Result: The mean age of the nurses was 26 and about 54% were university graduates. Of the 39 middle range categories those rated as the top ten were transfusion (4.682), IV injection (4.492), po medication (4.476), surgery (4.469), infection control (4.438), IM injection (4.413), safety (4.388), oxygenation (4.376), diagnostic test (4.366), and fluid & electrolyte balance (4.359). The categories that had the lowest scores were sexuality (3.449), conceptual nursing (3.465), spirituality (3.527) and personal hygiene (3.548). Conclusion: The results of this study show that most nurses evaluate items which they use frequently in their practice as important.

  • PDF

The observation of permeation grouting method as soil improvement technique with different grout flow models

  • Celik, Fatih
    • Geomechanics and Engineering
    • /
    • v.17 no.4
    • /
    • pp.367-374
    • /
    • 2019
  • This study concluded the results of a research on the features of cement based permeation grout, based on some important grout parameters, such as the rheological properties (yield stress and viscosity), coefficient of permeability to grout ($k_G$) and the inject ability of cement grout (N and $N_c$ assessment), which govern the performance of cement based permeation grouting in porous media. Due to the limited knowledge of these important grout parameters and other influencing factors (filtration pressure, rate and time of injection and the grout volume) used in the field work, the application of cement based permeation grouting is still largely a trial and error process in the current practice, especially in the local construction industry. It is seen possible to use simple formulas in order to select the injection parameters and to evaluate their inter-relationship, as well as to optimize injection spacing and times with respect to injection source dimensions and in-situ permeability. The validity of spherical and cylindrical flow model was not verified by any past research works covered in the literature review. Therefore, a theoretical investigation including grout flow models and significant grout parameters for the design of permeation grouting was conducted in this study. This two grout flow models were applied for three grout mixes prepared for w/c=0.75, w/c=1.00 and w/c=1.25 in this study. The relations between injection times, radius, pump pressure and flow rate for both flow models were investigated and the results were presented. Furthermore, in order to investigate these two flow model, some rheological properties of the grout mixes, particle size distribution of the cement used in this study and some geotechnical properties of the sand used in this work were defined and presented.

Influence of review system using computerized program for Acute Respiratory Infection upon practicing doctors' behaviour (전산프로그램을 이용한 급성호흡기감염증 청구자료 심사 시행 후 개원의의 진료 및 청구 행태 변화)

  • Chung Seol-Hee;Park Eun-Chul;Jeong Hyoung-Sun
    • Health Policy and Management
    • /
    • v.16 no.2
    • /
    • pp.49-76
    • /
    • 2006
  • The aim of this study was to explore the effects of a computerized review program which was introduced in August 1, 2003, using claims data for acute respiratory infection related diseases. National Health Insurance (NHI) claims data on respiratory infection related diseases before and after the introduction, with six month intervals respectively, were used for the analysis. Clinic was the unit of observation, and clinics with only one physician whose specialty was internal medicine, pediatrics, otorhinolaryngology and family medicine and clinics with a general practitioner were selected. The final sample had 7,637 clinics in total. Indices used to measure practice pattern was prescription rates of antibiotics, prescription rates of injection drug per visit, treatment costs per claim, and total costs per claim. Changes in the number of claims for major disease categories and upcoding index for disease categories were used to measure claiming behavior. Data were analysed using descriptive analysis, t-test for indices changes before and after the introduction, analysis of variance (ANOVA) for practice pattern change for major disease categories, and multiple regression analysis to identify whether new system influenced on provider' practice patterns or not. Prescription of antibiotics, prescription rates of injection drug, treatment costs per claim, and total costs per claim decreased significantly. Results from multiple regression analysis showed that a computerized review system had effects on all the indices measuring behavior. Introduction of the new system had the spillover effects on the provider's behavior in the related disease categories in addition to the effects in the target diseases, but the magnitude of the effects were bigger among the target diseases. Rates of claims for computerized review over total claims for respiratory diseases significantly decreased after the introduction of a computerized review system and rates of claims for non target diseases increased, which was also statistically significant. Distribution of the number of claims by disease categories after the introduction of a computerized review system changed so as to increase the costs per claims. Analysis of upcoding index showed index for 'other acute lower respiratory infection (J20-22)', which was included in the review target, decreased and 'otitis media (H65, H66)', which was not included in the review target, increase. Factors affecting provider's practice patterns should be taken into consideration when policies on claims review method and behavior changes. It is critical to include strategies to decrease the variations among providers.

Sedative Effect and Changes in Blood Components in Cattle Given with Detomidine HCI (소에서 Detomidine 투여에 의한 진정효과 및 혈액성분의 변화)

  • Park Myeung-Ro;Nam Tchi-Chou;Kweon Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.6 no.1
    • /
    • pp.209-216
    • /
    • 1989
  • In order to investigate sedative action of detomidine and its effect on physical signs, hematological and blood chemical components, 15 Holstein cattle were used. The dosage of detomidine was 25 ${\mu}$g/kg and 50 ${\mu}$g/kg. Blood was collected before injection, 30, 60 and 120 min. after injection. Induction time of sedation in a cattle given with 25 ${\mu}$g/kg and 50 ${\mu}$g/kg of detomidine was 10.6${\pm}$2.8. 7.6${\pm}$1.0min. respectively and maintenance time was 70.4${\pm}$8.3, 86.5${\pm}$9.9, respectively. After injection of detomidine, body temperature was slightly increased, heart rate and respiratory rate were slightly decreased. The levels of red blood cell, hemoglobin, packed cell volume and white blood cell were not changed by detomidine. Blood glucose level following detomidine was markedly increased but total protein, serum glutamic oxaloacetic transminase, alkaline phosphatase, lactic dehydrogenase, blood urea nitrogen and creatinine were not changed. This results indicated that detomidine was useful sedative in bovine practice.

  • PDF

Effects of marbofloxacin injection for granuloma formation in fattening pigs (마보플록삭신 제품별 접종이 비육돈 목심 부위 이상육 발생에 미치는 효과)

  • Im, Chang-Won;Lee, Wan-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.3
    • /
    • pp.157-162
    • /
    • 2021
  • The abnormal meat could caused by abscess, fibrosis and granuloma in the region of the neck by adverse effect of vaccination or antibiotic injection under swine practice. In this study, the incidence of abnormal meat due to antibiotics injection was investigated using marbofloxacin from different manufacturers. To evaluate the incidence of abnormal meat via antibiotic treatment, a total of 440 pigs with the age of 140~150 days old were selected. Two hundred of pigs were assigned as a control group and 2 mL of saline was inoculated daily for three days. Two hundred forty of pigs were used as treatment group and further divided into 6 groups, consisting of 16% of original marbofloxacin treated, 10% of original marbofloxacin treated and 4 different kinds of generic marbofloxacin treated groups respectively. When test animals were slaughtered, incidence, type and size of induced abnormal meat were recorded. In the result of this study, statistical analysis found significantly lower incidence of abnormal meat formation was in 16% original marbofloxacin treated groups compared to the other tested groups (P<0.05). In the summary, antibiotic treatment could produce abnormal meat formation but the 16% of original marbofloxacin had the most minimal abnormal meat formation effect.

Single-Dose Intramuscular Toxicity Study of SU-Eohyeol Pharmacopuncture in Rats

  • Hwang, Ji Hye;Ku, Jaseung;Jung, Chul
    • Journal of Pharmacopuncture
    • /
    • v.25 no.3
    • /
    • pp.268-275
    • /
    • 2022
  • Objectives: This toxicological study was performed to assess for potential toxicity and to determine the approximate lethal dose of SU-Eohyeol pharmacopuncture (SUEP) following a single intramuscular injection of SUEP into male and female Sprague-Dawley (SD) rats. Methods: The groups in our experiment consisted of an experimental group treated with SUEP at a dose of 1.0 mL/animal and a control group injected with a normal saline solution, and five male and female rats were placed in each group. Each animal was administered a single intramuscular injection. We monitored all rats for clinical signs and body weight changes for 14 days after administration. At the end of the observation period, the rats were euthanized and autopsied, and localized tolerance examinations were conducted at the site of administration of the test substance. Results: There were no deaths in either sex in the SUEP-treated group. There was no significant difference between the SUEP-treated group and the control group in the clinical signs and weight changes among the rats. In addition, no significant SUEP-related changes were observed on autopsy findings or local tolerance examinations at the injection site by histopathological examination. Conclusion: Our results suggest that the approximate lethal dose of a single intramuscular administration of SUEP in female and male rats under the conditions of this study is greater than 1.0 mL/animal. To determine the safety of the use of SUEP in Korean medical clinical practice, additional toxicity studies will be needed.