• 제목/요약/키워드: Injection methods

검색결과 2,877건 처리시간 0.031초

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • 제34권3호
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF

Nuclear Imaging Evaluation of Galactosylation of Chitosan (핵의학 영상을 이용한 chitosan의 galactosylation 효과에 대한 평가)

  • Jeong, Hwan-Jeong;Kim, Eun-Mi;Park, In-Kyu;Cho, Chong-Su;Kim, Chang-Guhn;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • 제38권3호
    • /
    • pp.253-258
    • /
    • 2004
  • Purpose: Chitosan has been studied as a non-viral gene delivery vector, drug delivery carrier, metal chelator, food additive, and radiopharmaceutical, among other things. Recently, galactose-graft chitosan was studied as a non-viral gene and drug delivery vector to target hepatocytes. The aim of this study was to investigate the usefulness of nuclear imaging for in vivo evaluation of targeting the hepatocyte by galactose grafting. Methods and Materials: Galactosyl methylated chitosan (GMC) was produced by methylation to lactobionic acid coupled chitosan. Cytotoxicity of $^{99m}Tc$-GMC was determined by MTT assay. Rabbits were injected via their auricular vein with $^{99m}Tc$-GMC and $^{99m}Tc$-methylated chitosan (MC), the latter of which does not contain a galactose group, and images were acquired with a gamma camera equipped with a parallel hole collimator. The composition of the galactose group in galactosylated chitosan (GC), as well as the tri-, di-, or mono-methylation of GMC, was confirmed by NMR spectroscopy. Results: The results of MTT assay indicated that $^{99m}Tc$-GMC was non-toxic. $^{99m}Tc$-GMC specifically accumulated in the liver within 10 minutes of injection and maintained high hepatic uptake. In contrast, $^{99m}Tc$-MC showed faint liver uptake. $^{99m}Tc$-GMC scintigraphy of rabbits showed that the galactose ligand principally targeted the liver while the chitosan functionalities led to excretion through the urinary system. Conclusion: Bioconjugation with a specific ligand endows some degree of targetability to an administered molecule or drug, as in the case of galactose for hepatocyte in vivo, and evaluating said targetabililty is a clear example of the great benefit proffered by nuclear imaging.

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • 제37권2호
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제17권2호
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

The Evaluation of Usefulness of 99Mo-99mTc Generator Using(n,γ)99Mo Developed by Korea Atomic Energy Research ((n,γ)99Mo를 이용한 99Mo-99mTc발생기의 유용성 평가)

  • Seo, Han Kyung;Kim, Jeong Ho;Shim, Cheol Min;Kim, Byung Cheol;Choi, Do Cheol;Gwon, Yong Ju;Park, Yung Sun;Kim, Dong Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제17권2호
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo-^{99m}Tc$ generator is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. So $^{99}Mo-^{99m}Tc$ generator using$(n,{\gamma})^{99}Mo$ is developed by Korea Atomic Energy Research Institute (KAERI). Medicinal availability of this generator is evaluated in this study. Materials and Methods: The radioactivity of $^{99m}Tc$ eluted in generator 1, 2 and 3 unit developed by KAERI was measured. The quality control test of generator such as appearance test, pH test, LAL test, sterility test, chemical impurity (Al) test and radiochemical purity test were performed. Planar and SPECT/CT image sof SD rat (6 weeks, Female) at 2 hr after injection of $^{99m}Tc-HDP$ (hydroxymethylenediphosphonate) (TechneScan HDP, Malinckrodt Medical, Dutch) and $^{99m}Tc-DPD$ (diphosphono-1, 2-propanedicarboxylicacid) (TECEOS, CIS bio international, France) which were labeled with $^{99m}Tc$ eluted in KAERI and commercial generator (40.5 GBq, Malinckrodt Medical, Dutch) using SPECT/CT camera (Symbia, Siemense, Germany) were obtained respectively. Results: The mean radioactivity of $^{99m}Tc$ elution generator 1unit was 4.18 GBq (113 mCi), generator 2 unit was 4.73 GBq (128 mCi) and generator 3 unit was 3.33 GBq (90 mCi). All quality control tests were within normal limit except pyrogentest. Pyrogen test was positive. Planar and SPECT/CT images of rat injected $^{99m}Tc-HDP$ which was labeled with $^{99m}Tc$ eluted in commercial generator show increased uptake in bone, stomach and bowl. Planar images show increased uptake in liver and bone in case of $^{99m}Tc-DPD$. However, images of rat injected $^{99m}Tc-HDP$ and $^{99m}Tc-DPD$ which were labelled $^{99m}Tc$ eluted in KAERI generator show increased uptake in bone, liver and spleen. Conclusion: If shortcoming is removed such as pyrogen and liver appearance, domestic role as an alternative generator is thought to be able to fill and to secure the national medical service by supplying $^{99m}Tc$ when the supply of $^{99m}Tc$ be comes short.

  • PDF

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제17권2호
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF

GnRH Agonist Stimulation Test (GAST) for Prediction of Ovarian Response in Controlled Ovarian Stimulation (COH) (난소기능평가를 위한 Gonadotropin Releasing Hormone Agonist Stimulation Test (GAST)의 효용성에 관한 연구)

  • Kim, Mee-Ran;Song, In-Ok;Yeon, Hye-Jeong;Choi, Bum-Chae;Paik, Eun-Chan;Koong, Mi-Kyoung;Song, Il-Pyo;Lee, Jin-Woo;Kang, Inn-Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제26권2호
    • /
    • pp.163-170
    • /
    • 1999
  • Objectives: The aims of this study are 1) to determine if GAST is a better indicator in predicting ovarian response to COH compared with patient's age or basal FSH level and 2) to evaluate its role in detecting abnormal ovarian response. Design: Prospective study in 118 patients undergoing IVF-ET using GnRH-a short protocol during May-September 1995. Materials and Methods: After blood sampling for basal FSH and estradiol $(E_2)$ on cycle day two, 0.5ml (0.525mg) GnRH agonist ($Suprefact^{(r)}$, Hoechst) was injected subcutaneously. Serum $E_2$ was measured 24 hours later. Initial $E_2$ difference $({\Delta}E_2)$ was defined as the change in $E_2$ on day 3 over the baseline day 2 value. Sixteen patients with ovarian cyst or single ovary or incorrect blood collection time were excluded from the analysis. The patients were divided into three groups by ${\Delta}E_2$; group A (n=30):${\Delta}E_2$<40 pg/ml, group B (n=52): 40 pg/ml${\leq}{\Delta}E_2$<100 pg/ml, group C (n=20): ${\Delta}E_2{\leq}100$ pg/ml. COH was done by GnRH agonist/HMG/hCG and IVF-ET was followed. Ratio of $E_2$ on day of hCG injection over the number of ampules of gonadotropins used ($E_2hCGday$/Amp) was regarded as ovarian responsiveness. Poor ovarian response and overstimulation were defined as $E_2$ hCGday less than 600 pg/ml and greater than 5000 pg/ml, respectively. Results: Mean age $({\pm}SEM)$ in group A, B and C were $33.7{\pm}0.8^*,\;31.5{\pm}0.6\;and\;30.6{\pm}0.5^*$, respectively ($^*$: p<0.05). Mean basal FSH level of group $A(11.1{\pm}1.1mlU/ml)$ was significantly higher than those of $B(7.4{\pm}0.2mIU/ml)$ and C $(6.8{\pm}0.4mIU/ml)$ (p<0.001). Mean $E_2hCGday$ of group A was significantly lower than those of group B or C, i.e., $1402.1{\pm}187.7pg/ml,\;3153.2{\pm}240.0pg/ml,\;4078.8{\pm}306.4pg/ml$ respectively (p<0.0001). The number of ampules of gonadotropins used in group A was significantly greater than those in group B or C: $38.6{\pm}2.3,\;24.2{\pm}1.1\;and\;18.5{\pm}1.0$ (p<0.0001). The number of oocytes retrieved in group A was significantly smaller than those in group B or C: $6.4{\pm}1.1,\;15.5{\pm}1.1\;and\;18.6{\pm}1.6$, respectively (p<0.0001). By stepwise multiple regression, only ${\Delta}E_2$ showed a significant correlation (r=0.68, p<0.0001) with $E_2HCGday$/Amp, while age or basal FSH level were not significant. Likewise, only ${\Delta}E_2$ correlated significantly with the number of oocytes retrieved (r=0.57, p<0.001). All four patients whose COH was canceled due to poor ovarian response belonged to group A only (Fisher's exact test, p<0.01). Whereas none of 30 patients in group A (0%) had overstimulation, 14 patients among 72 patients (19.4%) in group B and C had overstimulation (Fisher's exact test, p<0.01). Conclusions: These data suggest that initial $E_2$ difference after GAST may be a better prognostic indicator of ovarian response to COH than age or basal FSH level. Since initial $E_2$ difference demonstrates significant association with abnormal ovarian response such as poor ovarian response necessitating cycle cancellation or overstimulation, GAST may be helpful in monitoring and consultation of patients during COH in IVF-ET cycle.

  • PDF

Seismic Data Processing and Inversion for Characterization of CO2 Storage Prospect in Ulleung Basin, East Sea (동해 울릉분지 CO2 저장소 특성 분석을 위한 탄성파 자료처리 및 역산)

  • Lee, Ho Yong;Kim, Min Jun;Park, Myong-Ho
    • Economic and Environmental Geology
    • /
    • 제48권1호
    • /
    • pp.25-39
    • /
    • 2015
  • $CO_2$ geological storage plays an important role in reduction of greenhouse gas emissions, but there is a lack of research for CCS demonstration. To achieve the goal of CCS, storing $CO_2$ safely and permanently in underground geological formations, it is essential to understand the characteristics of them, such as total storage capacity, stability, etc. and establish an injection strategy. We perform the impedance inversion for the seismic data acquired from the Ulleung Basin in 2012. To review the possibility of $CO_2$ storage, we also construct porosity models and extract attributes of the prospects from the seismic data. To improve the quality of seismic data, amplitude preserved processing methods, SWD(Shallow Water Demultiple), SRME(Surface Related Multiple Elimination) and Radon Demultiple, are applied. Three well log data are also analysed, and the log correlations of each well are 0.648, 0.574 and 0.342, respectively. All wells are used in building the low-frequency model to generate more robust initial model. Simultaneous pre-stack inversion is performed on all of the 2D profiles and inverted P-impedance, S-impedance and Vp/Vs ratio are generated from the inversion process. With the porosity profiles generated from the seismic inversion process, the porous and non-porous zones can be identified for the purpose of the $CO_2$ sequestration initiative. More detailed characterization of the geological storage and the simulation of $CO_2$ migration might be an essential for the CCS demonstration.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제16권2호
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제14권1호
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF