• 제목/요약/키워드: Injection methods

검색결과 2,877건 처리시간 0.027초

2.2L 직분사 디젤 엔진에서 LNT 촉매 재생을 위한 환원제 분사 방법 비교 (Comparison of the LNT Regeneration Methods in 2.2L Common Rail Direct Injection Diesel Engine)

  • 남충우;한만배
    • 한국자동차공학회논문집
    • /
    • 제23권2호
    • /
    • pp.169-177
    • /
    • 2015
  • In this study we investigated the regeneration methods for the lean $NO_x$ trap (LNT) catalyst in a 2.2L direct injection diesel engine. The regeneration methods were 1) in-cylinder post fuel injection and 2) external fuel injection strategy. The in-cylinder post fuel injection method uses in-cylinder injectors with the addition of the post fuel injection to supply enough reductants such as CO, $H_2$, THC. The external fuel injection method was enabled by installing a fuel injector with a wide spray angle before the LNT catalyst. Through the engine experiment, the $NO_x$ conversion efficiency, the amount of reductant exhaust gases, fuel consumption, and temperature behavior in the LNT catalyst were evaluated and compared for the two regeneration methods.

Consideration of the Carrier Based Signal Injection Method in Three Shunt Sensing Inverters for Sensorless Motor Control

  • Jung, Sungho;Ha, Jung-Ik
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1791-1801
    • /
    • 2016
  • This paper considers a carrier based signal injection method for use in the three shunt sensing inverter (TSSI) for sensorless motor control. It also analyzes the loss according to the injection axis of the voltage signal. To remove both the phase current and rotor position sensors, a sensorless method and a phase current reconstruction method can be simultaneously considered. However, an interaction between the two methods can be incurred when both methods inject voltage signals simultaneously. In this paper, a signal injection based sensorless method with the 120° OFF Discontinuous PWM (DPWM) is implemented in a TSSI to avoid this interaction problem. Since one leg does not have a switching event for one sampling period in the 120° OFF DPWM, the switching loss is altered according to the injection axis. The switching loss in the d-axis injection case can be up to 32% larger than that in the q-axis injection case. Other losses according to the injection axis are also analyzed.

주사실습 교육방법이 간호학생의 불안에 미치는 영향 (Effects of Injection Practice Education Methods on Anxiety in Nursing Students)

  • 최성녀
    • 부모자녀건강학회지
    • /
    • 제19권1호
    • /
    • pp.17-24
    • /
    • 2016
  • Purpose: This study examined the level of students' anxiety depending on the injection type, education methods, and the students' characteristics. Methods: 209 first year nursing students were randomly assigned to each group by three factors -injection methods, video watching, and number of practice. Injection methods had two levels (IV and IM). Video watching also had also two levels (video watching and non-watching group). And the number of practice had 4 levels according to number of practice (2, 4, 6, and 8 times). The video watching group was watching 30 minutes video before manikin practice. After 5 to 15 minutes of manikin practice, the sufficiency of practice and the level of anxiety were measured. The data were analyzed by t-test and one way ANOVA. Results: The anxiety of the IV practice was higher than that of IM. The students who have experiences of working at hospital or the similar institution were lower in anxiety. The higher self-confident in sufficiency of practice lowered the students' anxiety. But watching video and the number of practices had no effects on the level of anxiety. Conclusion: To effectively lower the anxiety of nursing students in the nursing practice education, lecture methods and education tools are needed to develop.

  • PDF

성대주입에 의한 성대수술 -수술수기 및 주입물질을 중심으로- (Phonosurgical Vocal Fold Injection)

  • 최홍식;김성수
    • 대한후두음성언어의학회지
    • /
    • 제12권1호
    • /
    • pp.5-10
    • /
    • 2001
  • 성대 내 주입에 의한 음성수술은 적절한 접근방법을 통해 적절한 주입물을 선택한다면 여러가지 음성장애에 대한 매우 우수한 치료중의 하나이다. 자가지방이 성대내주입술과 내시경적 성대내주입술은 최근에 개발된 수술방법이다. 성대 내 주입물질을 다룰 때 반드시 세심한 주의를 기울여야하고, 환자의 요구에 맞게 환자의 현 상태에 가장 적합한 주입물을 선택하도록 하여야 하며, 시술 시에는 주입하려고 하는 정확한 위치에 주입하여야 한다.

  • PDF

산업폐수의 효율적 처리를 위한 응집제의 주입방법 결정 (Determination of the Coagulant Injection Methods for Efficient Treatment of Industrial Wastewater)

  • 박세진;정병길
    • 한국환경기술학회지
    • /
    • 제19권6호
    • /
    • pp.570-575
    • /
    • 2018
  • 폐수수탁처리업에 반입되는 산업폐수의 원수 성상이 매일 달라짐에 따라 전처리 공정인 응집침전공정의 효율적 운전이 어려운 실정이며, 이로 인해 후처리공정인 증발농축 및 대체 공정인 membrane 공정의 부하원인이 되고 있다. 이에 본 연구에서는 산업폐수의 효율적 처리를 위해 응집제 주입 방법별(단독주입, 동시주입, 순차주입, 역주입) 응집특성을 비교하기 위해 NaOH 주입 전 후 폐수 원수를 채수하여 실험하였다. 응집실험은 Jar-tester를 이용하여 진행하였다. 응집제주입방법별 TDS 제거효율은 순차주입(2.8 %) < 단독주입(3.9 %) < 동시주입(8.1 %) < 역주입(9.6 %) 순으로, TOC 제거효율은 단독주입(84.3 %) < 역주입(86.2 %) < 순차주입(88.6 %) < 동시주입(89.1 %) 순으로, 탁도 제거효율은 단독주입(99.7 %) < 순차주입(99.8 %) ${\fallingdotseq}$ 역주입(99.8 %) < 동시주입(99.9 %) 순으로 각각 나타내어, 이를 종합적으로 고려하여 판단한 결과 순차주입방법(무기응집제${\rightarrow}$고분자응집제)보다 무기응집제 및 고분자응집제를 동시에 주입하는 방법이 더 효율적인 것으로 나타났다.

컴퓨터 시뮬레이션과 다구치 방법을 이용한 냉각 필터 사출성형 공정의 최적화 (Optimizing the Injection Molding Process for Cooling Filter Using Computer Simulation and Taguchi Methods)

  • 이승훈;민병현;김병곤
    • 산업공학
    • /
    • 제15권3호
    • /
    • pp.263-269
    • /
    • 2002
  • The injection molding process is a one of the most efficient techniques for manufacturing plastic parts of complex shape at low cost. In injection molding, molten plastic material is injected into the mold and cooled. Selection of molding conditions greatly affects the quality of molded parts. In this case study, we attempted to optimize the injection molding condition for a cooling filter using Taguchi experimental design methodology. The injection molding experiments were carried out using the Moldflow simulation software.

정밀 광학부품의 복굴절 분석을 통한 각종 성형법의 영향에 관한 연구 (The Effect of Various Molding Methods for Precision Optical Products Using Birefringence Analysis)

  • 민인기;조성우;윤경환
    • 소성∙가공
    • /
    • 제22권1호
    • /
    • pp.48-53
    • /
    • 2013
  • As the adoption of injection molding technology increases, injected-molded optical products require higher dimensional accuracy and optical stability than ever before. In the present study, four kinds of molding methods, i.e., conventional injection molding (CIM), injection/compression molding (ICM), rapid heat and cooling the mold(RHCM) and rapid injection/compression molding (RICM) were selected in order to investigate the optical anisotropy of a 7 inch Light Guide Plate(LGP) by examining the gap-wise distribution of birefringence and the extinction angle. The results indicate that the compression process can decrease flow-induced birefringence over the whole region and that rapid heating can decrease the birefringence level better than conventional molding. In addition, for the combination of compression and rapid heating a reversal flow was detected from the distribution of the extinction angle near the gate.

가솔린기관의 시동시 연료분사기법에 의한 HC 배출저감 연구 (A Study on the Reduction of HC Emissions by Fuel Injection Methods during the SI Engine Start)

  • 김성수
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.257-262
    • /
    • 2003
  • Engine-out HC emissions were investigated during engine start. The tests were conducted on a 1.5L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine at different coolant temperatures and fuel injection-skip methods; no skip, 1 cycle-skip and 3 cycle-skip. To understand the characteristics of engine-out HC emissions, HC concentration was measured at a exhaust port using a Fast Response Flame Ionization Detector (FRFID). The result show that HC emissions were emitted at the cold coolant temperature much higher than those of the hot coolant. In additions, the fuel injection skip highly reduced engine-out HC emissions. It is convinced that optimized fuel injection skips according to coolant temperatures could be applied to reduce HC emissions during SI engine start.

  • PDF

성대주입술 (Injection Laryngoplasty)

  • 선동일
    • 대한후두음성언어의학회지
    • /
    • 제24권2호
    • /
    • pp.88-95
    • /
    • 2013
  • In recent years, the application of injection laryngoplasty to a variety of laryngeal disorders has regained popularity. The technique of injection laryngoplasty has several appealing qualities including relative technical ease, low cost, and wide availability in many clinical settings. A growing number of injectable substances and injection methods have been developed. This review is intended to provide an updated discussion of indications, materials, and techniques for injection laryngoplasty.

  • PDF

인도페놀법을 이용한 수용액 중 암모니아 정량에 관한 연구 : 평형법, 반응속도법, 흐름주입분석법의 비교와 평가 (Determination of Aqueous Ammonia with Indophenol Method : Comparision and Evaluation for the Reaction-Rate, Equilibrium and Flow-Injection Analysis Methods)

  • 정형근;김범식
    • 한국환경과학회지
    • /
    • 제4권1호
    • /
    • pp.91-103
    • /
    • 1995
  • The reaction rate, equilibrium, and flow injection analysis methods were fundamentally evaluated for the determination of aqueous ammonia. The selected indophenol blue method was based on the formation of indophenol blue in which ammonium ion reacted with hypochlorite and phenol in alkaline solution. In the optimized reaction condition, the reaction followed 1st order reaction kinetics and the final product was stable. The absorbance measurements before and after the equilibrium were utilized for the reaction rate and equilibrium methods. The reaction rate methods, based on the relative analytical signals for the possibility of eliminating interferents, were shown to have good linear calibration curves but the detection limit and the calibration sensitivity were poorer than those in the equilibrium method. The detection limits were 32-49 pub and 24 pub for the reaction rate and equilibrium methods, respectively In the flow injection analysis, the absorbance was measured before the equilibrium reached and thus resulted in 30% reduction of calibration sensitivity. However, the detection limit was 11 ppb, indicating that the peak-to-peak noise for the blank was remarkably improved. Compared to the manual methods, the optimized experimental condition in a closed reaction system reduced the blank absorbance and the inclusion of ammonia from the atmosphere was prevented. In addition, highly reproducible mixing of sample and reagents and analytical data extracted from continuous recording showed excellent reproducibility.

  • PDF