• Title/Summary/Keyword: Injection distance

Search Result 316, Processing Time 0.023 seconds

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.

Piriformis Muscle: Clinical Anatomy with Computed Tomography in Korean Population

  • Park, Chan-Hong;Lee, Sang-Ho;Lee, Sang-Chul;Park, Hahck-Soo
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.87-92
    • /
    • 2011
  • Backgroud: The objective was to evaluate the distance from the skin and the diameter of the piriformis muscle and their relationship to the body mass index (BMI). Methods: The study was a prospective study involving 60 patients. Patients were prepared on a radiological table in the prone position. Several images were obtained of each. In this view, the distance between the subcutaneous tissue and the piriformis muscle, and the diameter of the piriformis, were measured at three points (medially to laterally). Results: The distance to the piriformis from the skin was $6.6{\pm}0.9\;cm$, $6.3{\pm}0.8\;cm$, and $5.2{\pm}0.9\;cm$ in terms of the lateral, center, and medial measurement, respectively. The center of the piriformis had a greater diameter with $1.7{\pm}0.4\;cm$ (0.9-2.5) cm. The distance to the piriformis increased with BMI. Conclusions: This study shows that the lateral of the piriformis muscle has a relatively greater distance from the skin. The center of the piriformis showed a greater diameter than other two portions. We found that the distance of the piriformis from subcutaneous tissues was correlated with BMI, but the diameter of the piriformis was not affected by BMI. These measurements can be used as a reference for determining the piriformis injection site in patients with piriformis syndrome.

Analysis of grout injection distance in single rock joint (단일절리 암반에서 그라우팅 주입거리 분석)

  • Ji-Yeong Kim;Jo-Hyun Weon;Jong-Won Lee;Tae-Min Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.541-554
    • /
    • 2023
  • The utilization of underground spaces in relation to tunnels and energy/waste storage is on the rise. To ensure the stability of underground spaces, it is crucial to reinforce rock fractures and discontinuities. Discontinuities, such as joints, can weaken the strength of the rock and lead to groundwater inflow into underground spaces. In order to enhance the strength and stability of the area around these discontinuities, rock grouting techniques are employed. However, during rock grouting, it is impossible to visually confirm whether the grouting material is being smoothly injected as intended. Without proper injection, the expected increases in strength, durability, and degree of consolidation may not be achieved. Therefore, it is necessary to predict in advance whether the grouting material is being injected as designed. In this study, we aimed to assess the injection performance based on injection variables such as the water/cement mixture ratio, injection pressure, and injection flow using UDEC (Universal Distinct Element Code) numerical program. Additionally, numerical results were validated by the lab experiment. The results of this study are expected to help optimize variables such as injection material properties, injection time, and pump pressure in the grouting design in the field.

Numerical Study on Improvement of Mixing Equipment' Plan in a Water Treatment Plant (수리해석을 이용한 정수장내 혼화장치 설계 개선에 관한 연구)

  • Oh, S.Y.;Hyun, D.S.;Oh, J.J.;Lee, S.H.;Lee, N.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.777-782
    • /
    • 2001
  • In this study, we used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Numerical study was performed using FLUENT, a commercial code, to standard design and production of effective In-line orifice mixer. As variable for exactly standardizing, a proper ratio between an outer diameter of cone and a diameter of pipe, a distance between cone and orifice, a determination of orifice diameter for an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant (정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석)

  • Song K. S.;Oh S. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.132-137
    • /
    • 2001
  • We used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Code of computational fluid dynamics for numerical analysis was performed using FLUENT, a commercial code. As variable for exactly standardizing, a proper ratio between an outer diameter of deflector and a diameter of pipe, the distance between deflector and orifice, a determination of orifice diameter fur an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Mass Distribution and Spray Characteristics to Liquid-Gas Line Selection of Unlike Triplet Impinging Injector (비동질 3중 충돌형 인젝터의 기체-액체 라인 선택에 따른 분무특성)

  • Lee, I.C.;Lee, C.J.;Koo, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.205-211
    • /
    • 2006
  • Impinging angle, impinging distance, length eve. diameter and injection pressure of a triplet injector were tested to evaluate the spray characteristics injected by liquid/gas combinations. Two different kinds of unlike triplet sprays were produced by changing the gas and liquid feed lines. One was the G-L-G(Gas-Liquid-Gas) type, and the other was L-G-L(Liquid-Gas-Liquid) type. Spray angles were wider with the G-L-G type than with L-G-L type. Mass distributions in spray were obtained with a, mechanical patternator. Mass distributions were not circular but elliptical distributions. When the range of mechanical patternator to injector decreased, mass distributions were more concentrated in the center region.

  • PDF

Experimental Study on Spray Etching Process In Micro Fabrication of Lead Frame

  • Jung, Ji-Won;Choi, Gyung-Min;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2294-2302
    • /
    • 2004
  • The objective of this study is to obtain detailed information for the micro fabrication of lead frames by applying spray technology to wet etching process. Wet etching experiments were performed with different etching parameters such as injection pressure, distance from nozzle tip to etched substrate, nozzle pitch and etchant temperature. The characteristics of single and twin spray were measured to investigate the correlation between the spray characteristics and the etching characteristics. Drop size and velocity were measured by Phase-Doppler Anemometer (PDA). Four liquids of different viscosity were used to reveal the effects of viscosity on the spray characteristics. The results indicated that the shorter the distance from nozzle tip and the nozzle pitch, the larger etching factor became. The average etching factor had good positive correlation with average axial velocity and impact force. It was found that the etching characteristics depended strongly on the spray characteristics.

A Behavior Study of Diesel Spray on High Temperature (고온 분위기에서 디젤 분무의 거동에 관한 연구)

  • Ryu, H.S.;Chong, I.G.;Song, K.K.;YANO, T.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.410-415
    • /
    • 2000
  • A diesel engine is one of the major prime movers to its high thermal efficiency. But due to the recent attention far the environmental pollution, the emissions of diesel engine became to a important problem. So it is needed to understand the characteristics of diesel spray injected into a combustion chamber. The factor which controls the diesel spray are the injection pressure, the nozzle diameter, the impinging angle and the variation of pressure and temperature. In this paper, experiments were conducted far the variation of the environmental temperature(273k, 373k, 573k), free spray and impinging spray. And the notions of penetration, spray angle, axial distance for free spray, and axial distance, spray thickness from impinging wall fur impinging spray.

  • PDF

Characteristic of Tractor Attachment Boom Sprayer Nozzle (트랙터 부착 붐 방제기 노즐 분무특성)

  • Kang, TaeGyoung;Kim, Sungwoo;Kim, Youngkeun;Lee, Sanghee;Choi, Yong;Jun, Hyeonjong;Choi, Ilsoo;Kim, Hyeonggon
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.195-199
    • /
    • 2016
  • Spraying of nozzles and design of tractor-attached boom sprayers have been studied for analysis of liquid spraying features. The following conclusions have been drawn. At all pressures, twin flat spray tips was finer than flat spray tips. A fine spray with VMD of 101 to 200 appeared at 1.5MPa. So, it was selected as the boom sprayer nozzle. In spraying uniformity analysis, Type B was proven to have more uniformity than Type A and Type C at 52.0 cm attached distance. Type A and Type C were proven to have more uniformity than Type B at 58.5 cm attached distance. It is concluded that these results reflect atomizing characteristics of nozzles during pest control with tractor-attached boom sprayer. Therefore, optimum setting will be putting Type C with 58.5 cm distance.

Characteristics of the Droplet Behavior in the Overlap Region of Twin Spray and in Single Spray (이중분무의 중첩영역과 단일분무에서 액적의 거동 특성)

  • Jung, Ji-Won;Cha, Keun-Jong;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1300-1308
    • /
    • 2000
  • The objectives of this study was to investigate the spray characteristics of single spray and twin spray in the overlap region such as mean axial velocity, mean radial velocity, mean droplet size and probability density function of droplet size. A phase doppler anemometer was used as the measurement system for droplet size and velocity. In case of single spray, injection pressure was varied from 0.2MPa to 0.7MPa. Mean axial velocity, mean radial velocity and droplet size were decreased as the distance below nozzle tip was increased. In case of twin spray, the spray characteristics were measured by varying the distance between two nozzles from 127mm to 155mm. In the overlap region, the boundary of the overlap region was determined by obtaining the distribution of mean axial and radial velocity. Droplet size was increased as the distance from nozzle tip was increased. It was found that the distribution of droplet size for twin spray in the overlap region was different to single spray.