• Title/Summary/Keyword: Injection Unit

Search Result 362, Processing Time 0.024 seconds

Effect of Intake Flow Control Method on Part Load Performance in SI Engine(1) - Comparison of Throttling and Masking (스파크점화기관에서 흡기제어 방식이 부분부하 성능에 미치는 영향(1) - 스로틀링과 마스킹의 비교)

  • Kang, Min Gyun;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.156-165
    • /
    • 2014
  • This paper is the first investigation on the effect of flow control methods on the part load performance in a spark ignition engine. For comparison of the methods, two control devices, port throttling and masking, were applied to a conventional engine without any design change of the intake port. Steady flow evaluation shows that steady flow rates per unit opening area and swirl ratio are very low compared with the port throttling and saturated from mid-stage valve lift, however, swirl increases slightly as the lift is higher in case of 1/4 masking control. In the part load performance, the effect of simple port throttling on lean misfire limit expansion is limited and insufficient; on the other hand a masking improves the limit considerably without any port modification for increasing swirl. Also the results show that the intake flow control improves the combustion with following two mechanisms: stratification induced by the combination of the flow pattern and the fuel injection timing attribute to ignition ability and the intensified flow ensure fast burn. In addition fuel consumption reduces under the flow controls and the reduction rate is different according to the operation conditions and control methods. At the Stoichiometric and/or low speed and low load the throttling method is more advantageous; however vice versa at lean and high load condition. Finally, the throttling is more efficient for HC reduction than masking, on the other side the NOx emissions increase under the masking and decrease under the port throttling compared with conventional port scheme.

Effects of Electrical Stimulation of Brainstem Nuclei on Dorsal Horn Neuron Responses to Mechanical Stimuli in a Rat Model of Neuropathic Pain (신경병증성 통증 모델 쥐에서 뇌간 핵의 전기자극이 후각세포의 기계자극에 대한 반응도에 미치는 영향)

  • Leem Joong-Woo;Choi Yoon;Gwak Young-Seob;Nam Taik-Sang;Paik Kwang-Se
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.3
    • /
    • pp.241-249
    • /
    • 1997
  • The aim of the present study is to examine the brainstem sites where the electrical stimulation produces a suppression of dorsal horn neuron responses of neuropathic rats. An experimental neuropathy was induced by a unilateral ligation of L5-L6 spinal nerves of rats. Ten to 15 days after surgery, the spinal cord was exposed and single-unit recording was made on wide dynamic range (WDR) neurons in the dorsal horn. Neuronal responses to mechanical stimuli applied to somatic receptive fields were examined to see if they were modulated by electrical stimulation of various brainstem sites. Electrical stimulation of periaqueductal gray (PAG), n. raphe magnus (RMg) or n. reticularis gigantocellularis (Gi) significantly suppressed responses of WDR neurons -to both noxious and non-noxious stimuli. Electrical stimulation of other brainstem areas, such as locus coeruleus. (LC) and n. reticularis paragigantocellularis lateralis (LPGi), produced little or no suppression. Microinjection of morphine into PAG, RMg, or Gi also produced a suppression as similar pattern to the case of electrical stimulation, whereas morphine injection into LC or LPGi exerted no effects. The results suggest that PAG, NRM and Gi are the principle brainstem nuclei involved in the descending inhibitory systems responsible for the control of neuropathic pain. These systems are likely activated by endogenous opioids and exert their inhibitory effect by acting on WDR neurons in the spinal cord.

  • PDF

A Study Left Ventricular Volume Change Measurement using Nuclear Stethoscope (핵청진기를 이용한 좌심실 부피변화 측정에 관한 연구)

  • Min, Byeong-Gu;Kim, Yeong-Ho;Go, Chang-Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.167-172
    • /
    • 1984
  • In the present study, we developed a nuclear stethoscope interfaced with a personal computer (APPLE- II) and evaluated it's performances as compared with the gamma camera. This single-probe, ECG-gated system has been used for displaying the left ventricular time-activity curves, the peak ejection time and its rate, the peak filling time and its rate, and the R-R interval distribution. The radioactivity was measured at every 10msec around the ventricular region, where the activity curves shows the maximal peak to peak variations. The background activity was measured around the lung area showing its counts approximately 50% of the end-diastolic count with minimal variations. The average time-activity curves of 100 beats were used for analysis in the equilibrium study after intravenous injection of 15-20mCi of Tc. The ejection fractions measured by the nuclear stethoscope(Y) were compared with those measured by gamma camera(X) in 47 patients with various heart diseases. The correlation coefficient between two measurements was 0.766 with a relation of Y=1.04 x-8.48. Also, the high reproducibility was obtained for the same patient. Also, the high reproducibility was obtained for the same patient. From this study, we conclude that this device is useful for continuous monitoring in the intensive care unit, as it is portable, compact, and inexpensive.

  • PDF

Design of an Automatic Titration System for Caustic Soda Treatment System Using the Equivalent Point Estimation Algorithm (당량점 예측 알고리듬에 의한 가성소다 처리 섬유감량 시스템용 자동적정 장치 설계)

  • Cho, Jin-Ho;Jin, Kyoung-Chan;You, Byoung-Heui;Koo, Sung-Mo;Kim, Myoung-Nam;Lee, Jong-Hyun;Lee, Heung-Lark
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.28-35
    • /
    • 1994
  • Caustic Soda Treatment Systems need a concentration measurement device in order to monitor the weight reduction amount of polyester fabrics. Since the reduction process requires several concentration measurements, we have to do the unit titration fast and exactly. Therefore, a proposition of estimation algorithm for finding the equivalent point in the titration process is needed. In this paper, we used the cardinal spline algorithm, to estimate the proper curve with the measured pH-values after each injection of titration sdution, to predict the equivalent point. While the processing time is elapsed, several equivalent points are estimated and drawed the line graph of fabrics weight reduction automatically. Finally, we designed the hardware and the software of an automatic titration system that can generate the reduction ending signal of Caustic Soda Treatment System.

  • PDF

Fabrication and Characterization of Dye-sensitized Solar Cells based on Anodic Titanium Oxide Nanotube Arrays Sensitized with Heteroleptic Ruthenium Dyes

  • Shen, Chien-Hung;Chang, Yu-Cheng;Wu, Po-Ting;Diau, Eric Wei-Guang
    • Rapid Communication in Photoscience
    • /
    • v.3 no.1
    • /
    • pp.16-19
    • /
    • 2014
  • Anodic self-organized titania nanotube (TNT) arrays have a great potential as efficient electron-transport materials for dye-sensitized solar cells (DSSC). Herewith we report the photovoltaic and kinetic investigations for a series of heteroleptic ruthenium complexes (RD16-RD18) sensitized on TNT films for DSSC applications. We found that the RD16 device had an enhanced short-circuit current density ($J_{SC}/mAcm^{-2}=15.0$) and an efficiency of power conversion (${\eta}=7.2%$) greater than that of a N719 device (${\eta}=7.1%$) due to the increasing light-harvesting and the broadened spectral features with thiophene-based ligands. However, the device made of RD17 (adding one more hexyl chain) showed smaller $J_{SC}(14.1mAcm^{-2})$ and poorer ${\eta}(6.8%)$ compare to those of RD16 due to smaller amount of dye-loading and less efficient electron injection for the RD17 device than for the RD16 device. For the RD18 dye (adding one more thiophene unit and one more hexyl chain), we found that the device showed even lower $J_{SC}(13.2mAcm^{-2}) $ that led to a poorest device performance (${\eta}=6.2%$) for the RD18 device. These results are against to those obtained from the same dyes sensitized on $TiO_2$ nanoparticle films and they can be rationalized according to the electron transport kinetics measured using the methods of charge extraction and transient photovoltage decays.

Combustion Characteristics of Waste Sewage Sludge using Oxy-fuel Circulating Fluidized Bed (슬러지 순산소 유동층 연소특성)

  • Jang, Ha-Na;Sung, Jin-Ho;Choi, Hang Seok;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.846-853
    • /
    • 2017
  • Cold bed and $30kW_{th}$ pilot bed tests using circulating fluidized bed (CFB) were conducted to apply oxy-fuel technology for waste sludge combustion as a carbon capture and storage technology. In cold bed test, the minimum fluidization velocity ($u_{mf}$) and superficial velocity for fast fluidization was determined as 0.120 m/s and 2.5 m/s, respectively. In the pilot test, air and oxy-fuel combustion experiments for waste sludge were conducted using CFB unit. The flue-gas temperature in 21~25% oxy-fuel combustion was higher than that of air and up to 30% oxy-fuel combustion. In addition, the concentration of carbon dioxide was more than 80% with the oxygen injection range from 21% to 25% in oxy-fuel CFB waste sludge combustion.

Analysis of Measuring Error for Particle Size Analysis by Laser Diffraction Spectrometer (입자크기분석을 위한 레이저회절 분광계의 측정오차 분석)

  • Ha, Sang-An;Son, Heui-Jeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.713-722
    • /
    • 2000
  • This study analysed error of measurement and reproducibility for particle size analysis by the laser diffraction spectrometer. Laser diffraction spectrometers has become a very important method of particle size analysis. This measuring method has the advantage of simple operation, good reproducibility and rapid analysis. A feeding and dispersing system have been developed, which allows mass throughputs between 0.1~23 g/min in flowing air and 1.4~35% in flowing liquid. It has been used as a feeder unit for wet and dry particle size analysis from diffraction patterns. Relevant parameters, such as particle shape, particle size, dispersion, flow rate, concentration were analysed for measuring error. And system parameters of instruments for measurement of dynamic processes, eg, measuring time, focal plane, injection pressure drop and dispersion effect by the ultrasonic and mixing of preliminary treatment, were also discussed.

  • PDF

An Analysis on the Factors Affecting Revisit and Defection of Long-term Outpatients in Neighboring Pharmacy of General Hospital (종합병원 장기처방환자의 인근 약국 재방문 및 이탈 요인 분석)

  • Oh, Chang-Kyun;Choi, Byung-Chul;Sohn, Uy-Dong
    • YAKHAK HOEJI
    • /
    • v.49 no.6
    • /
    • pp.449-458
    • /
    • 2005
  • There have been rapid changes in the pharmaceutical environment after the separation of Dispensing and Prescribing practice. In the early stage of this system, outpatients had few options to choose their pharmacies due to various obstacles. Under these circumstances, this study on the defection tendency of long-term care patients was performed through the analysis of outpatients who quit visiting a pharmacy nearby general hospital. PowerBuilder ver 9.0 program was used to extract significant data, and SPSS package was employed for statistic analysis. 3,308 outpatients who visited a pharmacy nearby hospital for a month (in January, 2004) were studied. Patients' sex, age and location of residence, the class of medical insurance, the characteristic type of medication (powder, split form, medication for external use/injection), waiting time, disease (department) were considered as variable factors. It turned out that the patient revisit ratio was 80.8$\%$ and the patient defection ratio was 32.4$\%$. As was expected, those factors mentioned above influenced on the revisit and defection ratio considerably. In terms of patient factors, it proved that there was no relationship among sex, location of residence, the class of medical insurance and revisit (defection) ratio. Only age factor influenced the ratio; the older, the higher revisit ratio and the less defection ratio. In respect of dispensing factors, there were obvious relationships among the factors and the ratio: bill (money they had to pay individually), waiting time, number of medications, splitting of tablets, unit price of drug and revisit (defection) ratio showed significant relationship. The result of this study revealed an aspect of outpatients' behavior and it could be used as a reference for better patient service and customer relationship management.

Characteristics of Electronically Controlled 13L LNG-Diesel Dual Fuel Engine (13L급 LNG-디젤 혼소엔진의 기초 성능 특성 연구)

  • Lee, Seok-Hwan;Lee, Jin-Wook;Heo, Seong-Joon;Yoon, Sung-Shik;Roh, Yun-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.54-58
    • /
    • 2007
  • The trailers with electronically controlled diesel engine was converted to dual fuel engine system. To estimate economical efficiency, test vehicles have been operated on a certain driving route repeatedly. Fuel economy, mximum driving distance per refueling and driveability are examined on the road including a free way. Developed vehicle can be operated over 500 km with dual Hel and shows 85% of diesel substitution ratio. Driveability is similar with but passing acceleration. It will be improved by calibration process. Test engine was set up for investigating power output, thermal efficiency and emission. ND 13-mode tests were performed for the test cycle. The emission result of dual fuel meets K2006 regulation and the engine performance of dual fuel engine was equivalent to the performance of diesel engine.

  • PDF

Production of Window Motor Assembly Parts in Automotive Body (자동차 전장에서 윈도우 모터 조립 부품의 생산)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.3 no.4
    • /
    • pp.29-34
    • /
    • 2012
  • Power window motor assembly including ECU system is important to doors of automobile. This study is done for own development instead of importing of power window motor assembly. This paper is written under five specific subjects. The first, making of prototype sample and analysis of mass-production problem using CAE, the second, design of mass-production mold(2D and 3D), the third, manufacturing of sample mold, the fourth, tryout and measuring of 3 dimensions, the fifth, data analysis and mold modify. In the among them, product sample and analysis of mass-production using CAE, design and manufacture of mass-production mold, and production of sample mold are successfully done. In the results, it is made clear that two cavity and one gate are proper to make a mold of power window motor assembly housing. Besides, it is acquired own technology for mass-production of power window motor.