• Title/Summary/Keyword: Injection Unit

Search Result 362, Processing Time 0.025 seconds

Force Control of Hybrid Actuator using Learning Vector Quantization Neural Network

  • Ahn, Kyoung-Kwan;Thai Chau, Nguyen Huynh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.290-295
    • /
    • 2005
  • Hydraulic actuators are important in modern industry due to high power, fast response, and high stiffness. In recent years, hybrid actuation system, which combines electric and hydraulic technology in a compact unit, can be adapted to a wide variety of force, speed and torque requirements. Moreover, the hybrid actuation system has dealt with the energy consumption and noise problem existed in the conventional hydraulic system. Therefore, hybrid actuator has a wide range of application fields such as plastic injection-molding and metal forming technology, where force or pressure control is the most important technology. In this paper, the solution for force control of hybrid system is presented. However, some limitations still exist such as deterioration of the performance of transient response due to the variable environment stiffness. Therefore, intelligent switching control using Learning Vector Quantization Neural Network (LVQNN) is newly proposed in this paper in order to overcome these limitations. Experiments are carried out to evaluate the effectiveness of the proposed algorithm with large variation of stiffness of external environment. In addition, it is understood that the new system has energy saving effect even though it has almost the same response as that of valve controlled system.

  • PDF

An Experimental Study on the Bed Combustion Phenomena in MSW(Municipal Solid Waste) Incinerator (폐기물 소각로 베드에서의 연소현상 관찰을 위한 실험적 연구)

  • Min, Jee Hyun;Shin, Donghoon;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.159-165
    • /
    • 1999
  • Experimental studies have been performed to observe the basic phenomena of waste bed combustion in MSW incinerator. A reduced scale apparatus was utilized to simulate the combustion behavior in real plant with 1-dimensional transient behavior at the experimental setup, which uses wet cubic wood with ash content as simulated waste. LHV (lower heating value) of solid fuel, fuel particle size and flow rate of combustion air were taken as important parameters of the bed combustion. For the quantitative analysis, FPR (flame propagation rate), TBT (total burn-out time) and PBT (particle burn-out time) was defined. LHV represent the capability of heat release of the fuel, so that a higher LHV results in faster reaction rate of the fuel bed, which is shown by higher FPR. Fuel particle size is related with surface area per unit mass as well as heat and mass transfer coefficient. As the particle size increases the FPR decreases owing to decreasing specific surface area. Air injection supplies oxygen to the reaction zone. However oversupply of combustion air increases convection cooling of the bed and possibly extinguishes the flame.

A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System (실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구)

  • Koo, Jeong-Hwan;Kim, Seong-Chan;Kim, Jang-Woo;Lee, Ju-Yong;Lee, Jae-Keun;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

A Case of Chemical Burn Caused by Trifluoroacetic Anhydride that Mimicked a Hydrofluoric Acid Burn (불화수소산에 의한 것으로 오인된 Trifluoroacetic anhydride에 의한 화학화상)

  • Park, Jung-Soo;Kim, Hoon;Lee, Suk-Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.8 no.1
    • /
    • pp.43-45
    • /
    • 2010
  • A 22-year-old woman was referred to our emergency department for the treatment of a chemical injury on her arm. She had accidentally spilled 99% trifluoroacetic anhydride (TFAA) over her left forearm during an organic chemistry experiment. She visited a primary care unit, and then she was referred to our hospital for inactivation of the released fluoride ions. Her skin lesions were different from those caused by hydrofluoric acid (HF) injury. The injured area showed painful whitish maculae and patchy areas with accentuated rim. No vesiculation and bulla formation was detected. We intradermally injected a 5% solution of calcium through a 24-gauge needle into the burned skin. After the injection, she complained of more severe pain. Although TFAA contains fluorine, it does not release free fluoride ions on contact with the skin, unlike HF. In fact, application of calcium gluconate for TFAA burns is not recommended. Rather, it should be avoided since it increases pain and local abscess formation.

  • PDF

A Study on the Fabrication Method of Mold for 7 inch LCD-BLU by continuous microlens 200μm (연속마이크로렌즈 200μm 적용 7인치 LCD-BLU 금형개발)

  • Kim, J.S.;Ko, Y.B.;Min, I.K.;Yu, J.W.;Heo, Y.M.;Yoon, K.H.;Hwang, C.J.
    • Transactions of Materials Processing
    • /
    • v.16 no.1 s.91
    • /
    • pp.42-47
    • /
    • 2007
  • LCD-BLU is one of kernel parts of LCD and it consists of several optical sheets: LGP, light source and mold frame. The LGP of LCD-BLU is usually manufactured by etching process and forming numerous dots with $50\sim300{\mu}m$ diameter on the surface. But the surface of the etched dots of LGP is very rough due to the characteristics of the etching process during the mold fabrication, so that its light loss is high along with the dispersion of light into the surface. Accordingly, there is a limit in raising the luminance of LCD-BLU. In order to overcome the limit of current etched dot patterned LGP, optical pattern with continuous microlens was designed using optical simulation CAE. Also, a mold with continuous micro-lens was fabricated by UV-LiGA reflow process and applied to 7 inch size of navigator LCD-BLU in the present study.

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • Song In Ho;Shin H. S.;Choi C. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.707-710
    • /
    • 2002
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute in Taejon to supply power with Korea Superconducting Tokamak Advanced Research (KSTAR) Neutral Beam Injection (NBI) system. NBI system requires fast cutoff of the power supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply and there are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply, Various results taken during the commissioning phase with a 100kW resistive load and NBI source are shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver and solutions are also presented.

  • PDF

Pharmacokinetics and Tissue Distribution of UTI in the Rat (랫드에서의 UTI의 약물동태학 및 조직 분포)

  • 정요찬;윤효인;조명행;박병권;발일현;김복환;송동호
    • Biomolecules & Therapeutics
    • /
    • v.4 no.3
    • /
    • pp.265-270
    • /
    • 1996
  • The purpose of this study was to determine pharmacokinetic parameters and tissue distribution patters of urinary trypsin inhibitor(UTI) in Sprague-Dawley rats. $Na^{125}$I was conjugated to UTI to make $^{125}I-UTI$ and the concentrations were determined by $\gamma$-counter. With the aid of nonlinear least-square regression analysis for i.v bolus injection of 1,000 unit UTI including $^{125}I-UTI$, the temporal concentration curves were best fitted by 2-compartment open model. The distribution phase half-life was 0.39$\pm$0.02 hours whereas the elimination half-life was 12.99$\pm$1.05 hours in male rats. The volume of distribution and total body clearance in male rats were 0.28$\pm$0.01 1/kg and 83.16$\pm$1.15 ml/kg/h, respectively. We could not find any difference of pharmacokinetic parameters of UTI between male and female rats. UTI were distributed widely in rat organs. In both male and female rats, the kidney was the highest distributed organ. Amount of UTI in 24 hour cumulative urine in male rats was 36.22$\pm$8.74% and that in 48 hours was 43.32$\pm$10.55%. Excretion via feces was very scanty, with the 24 hours cumulative amount being only 2.76$\pm$0.97%. This data suggest the main excretion route of UTI is urine.

  • PDF

Air handling unit utilizing water/air direct contact heat exchanger with mesh (공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구)

  • Jeon, Yong-Han;Mun, Myeong-Hun;Kim, Jong-Yoon;Kim, Nam-Jin;Seo, Tae-Boem;Kim, Chong-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1161-1166
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non-inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

  • PDF

DEVELOPMENT OF PYROPROCESSING AND ITS FUTURE DIRECTION

  • Inoue, Tadashi;Koch, Lothar
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.183-190
    • /
    • 2008
  • Pyroprocessing is the optimal means of treating spent metal fuels from metal fast fuel reactors and is proposed as a potential option for GNEP in order to meet the requirements of the next generation fuel cycle. Currently, efforts for research and development are being made not only in the U.S., but also in Asian countries. Electrorefining, cathode processing by distillation, injection casting for fuel fabrication, and waste treatment must be verified by the use of genuine materials, and the engineering scale model of each device must be developed for commercial deployment. Pyroprocessing can be effectively extended to treat oxide fuels by applying an electrochemical reduction, for which various kinds of oxides are examined. A typical morphology change was observed following the electrochemical reduction, while the product composition was estimated through the process flow diagram. The products include much stronger radiation emitter than pure typical LWR Pu or weapon-grade Pu. Nevertheless, institutional measures are unavoidable to ensure proliferation-proof plant operations. The safeguard concept of a pyroprocessing plant was compared with that of a PUREX plant. The pyroprocessing is better adapted for a collocation system positioned with some reactors and a single processing facility rather than for a centralized reprocessing unit with a large scale throughput.

Difference Between Nursing Demand and Perceived Nursing Performance in Hemodialysis Patients (혈액투석 환자의 간호요구도와 지각된 간호수행도 차이)

  • Kim, Son-Jung;Kim, Hee-Seung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.3
    • /
    • pp.310-316
    • /
    • 2011
  • Purpose: In the present study, the difference in patients' nursing demands and nursing performance as perceived by the patients was examined. Methods: The participants were 272 patients on maintenance hemodialysis at five university hospitals. Nursing need and nursing performance were measured using the tool developed by Lee for this study. Results: The mean score for nursing demand was 3.35 points out of 4. The scores were higher for participants with middle school graduation or less, those not professing religion, and those whose medical insurance was of the medicaid type. The mean score for perceived nursing performance was 3.22 points out of 4. Nursing performance as perceived by hemodialysis patients was lower than nursing demand for 22 of 28 items. The item with the largest difference between nursing performance and nursing demand was 'Give a pain-free injection', followed by 'Explain about insurance benefits and supports' and 'Maintain quiet environment in the hemodialysis unit enabling rest during hemodialysis'. Conclusion: The results show that nursing performance as perceived by hemodialysis patients was lower than nursing demand. This result indicates a need to develop appropriate strategies to enhance nursing performance, especially for items that showed low nursing performance.